Page 17

Features Send Start & End Sentinels: ON

;

Classic Line:

Value Line: ;

This option determines whether the Start and End Sentinels for each of the tracks are sent with the card data on a good read. The following is a table of the Start Sentinels per track: Track

Start Sentinel

1 2 3

% ; ; -or- ! -or- %

This option has no effect if the Data Output Mode is set to FIELD DATA. Send LRC Character: OFF Classic Line:

;

Value Line: ;

This option determines whether the Card Reader should transmit the LRC character as part of the card data. This option has no effect if the Data Output Mode is set to FIELD DATA. Send Mag Stripe Hardware Control Chars: ON Classic Line:

;

Value Line:

A magnetic stripe card can be encoded with special characters that are reserved for hardware control. This option allows the Card Reader to send or suppress these special characters. For a complete list of these characters, refer to AppendixB, Magnetic Stripe Character Sets. No Read Output String: Classic Line:

;

Value Line: ;

The No Read Output String is a string that is sent when the Card Reader is unable to read a magnetic stripe card. By default this string is empty, meaning that no characters are sent to the computer if the card is not read. Key in the string to be sent whenever the Card Reader is unable to read a magnetic stripe card. For full instructions on editing this field and the special characters that can be used, refer to the Preambles category. Maximum Length: Classic Line: (32 Chars) Value Line: (4 Chars)

Magnetic Stripe Editing

F3

The Magnetic Stripe editing options allow you to strip leading and trailing characters from the TRACK or FIELD DATA. If the Data Output Mode is set to TRACK DATA then the options for TRACK editing are available. If the Data Output Mode is set to FIELD DATA then the options for FIELD editing are available. Editing is the last operation on the card data prior to its transmission to the computer. Track 1 Stripping: # Of Leading Chars: 0 Track 2 Stripping: # Of Leading Chars: 0 Track 3 Stripping: # Of Leading Chars: 0 Classic Line:

;

Value Line:

These options allow you to strip up to 255 characters of leading data from the specific magnetic stripe track. If you attempt to strip more characters than there is data, no stripping will occur. Track 1 Stripping: # Of Trailing Chars: 0 Track 2 Stripping: # Of Trailing Chars: 0 Track 3 Stripping: # Of Trailing Chars: 0 Classic Line:

;

Value Line:

These options allow you to strip up to 255 characters of trailing data from the specific magnetic stripe track. If you attempt to strip more characters than there is data, no stripping will occur. ACCT # Stripping: # Of Leading Chars: 0 NAME Stripping: # Of Leading Chars: 0 EXP DATE Stripping: # Of Leading Chars: 0 Classic Line:

;

Value Line:

These options allow you to strip up to 255 characters of leading data from the specific field. If you attempt to strip more characters than there is data, no stripping will occur. ACCT # Stripping: # Of Trailing Chars: 0 NAME Stripping: # Of Trailing Chars: 0 EXP DATE Stripping: # Of Trailing Chars: 0 Classic Line:

;

Value Line:

17

Page 18

Features These options allow you to strip up to 255 characters of trailing data from the specific field. If you attempt to strip more characters than there is data, no stripping will occur.

) Note: If the Data Output Mode is set to TRACK DATA and you specify to strip 5 characters of leading data from Track 1, then all Track 1 data will be sent after removing the first 5 characters of data. If you then switch the Data Output Mode to FIELD DATA, the Track 1 stripping becomes stripping for the ACCT # and the ACCT # stripping will be set to strip 5 leading characters of data.

Preambles

F4

Magnetic Stripe Preamble: Classic Line:

;

Value Line: ;

The Magnetic Stripe Preamble is a string that is transmitted before any card data is transmitted. This string allows you to ensure that the cursor is positioned at the desired location at the time of a card swipe. When editing this option, you may use any of the standard keys on your keyboard. The HOME and END keys will take you to the beginning and end of the Preamble. In order to allow you to embed any key on the keyboard as part of the Preamble, the Card Reader uses certain ASCII characters as special function characters. Special function characters are followed by a two digit HEX value that specifies the attributes of the function. These characters and their function are as follows: Maximum Length: Classic Line: (32 Chars) Value Line: (5 Chars)

$

Classic Line:

;

Value Line:

;

Value Line:

;

Value Line:

;

Specifies special characters in the string. A special character is a character that performs a special operation or is a special key on the keyboard, such as a numeric keypad key. For example, to include an F1 key in the string, enter $80 in the string. For a list of all of the HEX values and the keys that they represent, refer to Appendix-A, Special Characters Table.

#

Classic Line:

Specifies an ALT keypad sequence. This is useful when you wish to transmit a graphic character to the computer. For example, to send ASCII 65, HEX 41 as an ALT keypad sequence, enter #41 sequence in the string. For a list of all of the HEX values and the keys that they represent, refer to Appendix-A, ALT Keypad Table.

% Classic Line:

Specifies international characters for the current Keyboard Country. International keys are keys such as the ACCENT key. These keys are specific to the Keyboard Country that is currently being used. The only time that you must use this key sequence to enter an international character is when your current Keyboard Country setting does not match the one that you wish to use to generate the character. If there are international characters in an input string and you change the Keyboard Country, the Card Reader will convert the international characters to % sequences for display purposes when configuring the unit. Classic Line: Value Line: ; *Indicates a delay in the string. This is useful if you desire the Card Reader to delay momentarily while transmitting the string to the computer. The HEX number that follows the * in the string is the number of hundredths of a second to delay before resuming transmission of the string and card data. The delay ranges from *00 (No delay) to *FF (2.55 second delay).

&

Classic Line:

;

Value Line:

Specifies a keyboard Scan Code to be sent. This option can be used to emulate a key if it cannot be sent with one of the above special characters. We recommend you use this option with caution because Scan Codes change for keyboard countries as well as keyboard interfaces and protocols. To determine the Scan Codes sent for a specific key, use Show Scan Codes in the Diagnostics category (F8). The HEX number that follows the & in the string is the Scan Code to be sent, to send multiple Scan Codes you must use & once for each Scan Code.

) Note: In order to include the $,#,%,* and & characters in the string, you must double the character. For example, to include a dollar sign and then a carriage return in a string, enter $$$0D at the string prompt. The consecutive dollar signs indicate that you want to transmit an actual $ and not a special character.

Track 1 Preamble: Track 2 Preamble: Track 3 Preamble: Classic Line:

;

Value Line: ;

18

Page 19

Features The Track 1, 2, 3 Preambles are strings that are transmitted prior to the Track card data. These options are only available if the Data Output Mode is set to TRACK DATA. Maximum Length: Classic Line: (32 Chars) Value Line: (4 Chars) ACCT # Preamble: NAME Preamble: EXP DATE Preamble: Classic Line:

;

Value Line:

The Account #, Name and Exp Date Preambles are strings that are transmitted prior to the specific field. These options are only available if the Data Output Mode is set to FIELD DATA. Maximum Length: Classic Line: (32 Chars) Send Preambles/Postambles for Unread Tracks: ON Classic Line:

;

Value Line: ;

This option determines if the Preambles/Postambles are transmitted for unread tracks of data. For example, if you swipe a Credit Card and Track 1 is read, but not Track 2, by default both Preambles/Postambles for Track 1 & 2 are transmitted. If you set this option to OFF, only the Preambles/Postambles for Track 1 will be transmitted.

) Note: Changing this option will also change the option under Postambles. Postambles

F5

Magnetic Stripe Postamble: Classic Line:

;

Value Line: ;

The Magnetic Stripe Postamble is a string that is transmitted after all card data is transmitted. This string allows you to ensure that the cursor is positioned at the desired location at the time of a card swipe. Editing in this field is done in the same manner as in the Preamble fields. Maximum Length: Classic Line: (32 Chars) Value Line: (5 Chars) Track 1 Postamble: Track 2 Postamble: Track 3 Postamble: Classic Line:

;

Value Line: ;

The Track 1, 2, 3 Postambles are strings that are transmitted after the Track card data. These options are only available if the Data Output Mode is set to TRACK DATA. Maximum Length: Classic Line: (32 Chars) Value Line: (4 Chars) ACCT # Postamble: NAME Postamble: EXP DATE Postamble: Classic Line:

;

Value Line:

The Account #, Name and Exp Date Postamble are strings that are transmitted after the specific field. These options are only available if the Data Output Mode is set to FIELD DATA. Maximum Length: Classic Line: (32 Chars) Send Preambles/Postambles for Unread Tracks: ON Classic Line:

;

Value Line: ;

This option determines if the Preambles/Postambles are transmitted for unread tracks of data. For example, if you swipe a Credit Card and Track 1 is read, but not Track 2, by default both Preambles/Postambles for Track 1 & 2 are transmitted. If you set this option to OFF only the Preambles/Postambles for Track 1 will be transmitted.

) Note: Changing this option will also change the option under Preambles.

19

Page 20

Features

Termination String

F6

Termination String: $0D Classic Line:

;

Value Line: ;

The Termination String is a string that is sent by default after all Track data and all Track Postambles. The default Termination String is the ENTER key. Key in the string that you wish to use as your termination string. Editing in this field is done in the same manner as in the Preamble fields. Or select the Character for the Termination String in the Combo box in the Universal Programmer software to specify the character. Maximum Length: Classic Line: (32 Chars) Value Line: (1 Character) Send Termination String: AFTER ALL TRACKS Classic Line:

;

Value Line: ;

This option is used to indicate where you wish the Card Reader to insert the termination string. The Termination String can be transmitted at the following locations: AFTER ALL TRACKS, AFTER EACH TRACK, BETWEEN TRACKS, AFTER ALL DATA, and OFF. By setting this option to BETWEEN TRACKS, the Termination String is sent between any two tracks of data. For example, if tracks 1, 2, and 3 were all read and the output order was the default 1,2,3, the Termination String will be sent after Track 1 and again after Track 2. By default the Termination String is sent after all tracks and all individual track Postambles.

Overview Of Card Data Transmission By now you realize the great amount of power and flexibility available in the ID Innovations Incorporated Card Reader. Along with great flexibility comes some increase in complexity, as evidenced by the manner in which all of the Termination String, Preambles and Postambles interact. For example, if you read a Triple-Track card in the TripleTrack version of the Card Reader and all of the Tracks are transmitted, the output will be as follows, assuming default values for all options: <Magnetic Stripe Preamble> <Track 1 Preamble><Track 1 Card Data><Track 1 Postamble> <Track 2 Preamble><Track 2 Card Data><Track 2 Postamble> <Track 3 Preamble><Track 3 Card Data><Track 3 Postamble> <Termination String> <Magnetic Stripe Postamble> If the Send Termination String option is set to AFTER EACH TRACK, then the following will be the output order if you read a Triple-Track card: <Magnetic Stripe Preamble> <Track 1 Preamble><Track 1 Card Data><Track 1 Postamble><Termination String> <Track 2 Preamble><Track 2 Card Data><Track 2 Postamble><Termination String> <Track 3 Preamble><Track 3 Card Data><Track 3 Postamble><Termination String> <Magnetic Stripe Postamble>

) Note: If the Data Output Mode is set to FIELD DATA, then the output order of the fields will follow the Field Output

Order and the Field Preambles and Postambles will be sent where the Track Preambles and Postambles are sent.

Buzzer/LED

F7

Good Read Beep: ONCE FOR ALL TRACKS Classic Line:

;

Value Line: ;

The Good Read Beep is used to configure the number of times the Card Reader beeps for each track of data read. The settings for this option are ONCE FOR ALL TRACKS, ONCE FOR EACH TRACK, and OFF. Beep Tone: MEDIUM Classic Line:

;

Value Line:

This option is used to change the tone that is generated on a good read. The available settings are LOW, MEDIUM, and HIGH. Beep Duration: MEDIUM Classic Line:

;

Value Line:

This options is used to change the duration of the good read beep. The available durations are SHORT, MEDIUM, and LONG.

20

Page 21

Features No Read LED Delay: 10 Classic Line:

;

Value Line:

The No Read LED delay is the amount of time that the LED displays red before returning to the ready green state. This input is in 10ths of a second and ranges from 0 to 65. The default is 10 for 1 second. A value of 0 will set the LED to red and it will not change back to green until a good read occurs. LED Power Save Mode: OFF Classic Line:

;

Value Line:

Use this option to enable or disable the LED Power Save Mode on the Card Reader. In the Power Save Mode the LED on the Card Reader will only light up on a good or bad read. If you have a bad or no read the LED will remain lit until the No Read LED Delay time has expired. In the Power Save Mode the unit will consume as little power as possible, this mode is excellent for use with LAPTOP computers where power consumption is a primary concern. Power Up Beep: ON Classic Line:

Value Line: ;

Use this option to enable or disable the Power Up Beep. This is the beep that is heard when power is first applied to the reader.

Diagnostics (PS2 Style-Classic Line)

F8

Firmware Version and Release Date Classic Line:

;

Value Line:

This option is an information only option, it displays the internal Firmware version and the Release Date of that firmware. This is useful when you wish to know the version and release date of an ID Innovations Incorporated Card Reader. Keyboard Information Classic Line:

;

Value Line:

This option displays the Keyboard ID, Protocol and Scan Code Set that the Magnetic Card Reader is using. For example, a message similar to the following is displayed when connected to a standard IBM AT or Compatible: :Keyboard ID=83AB

Protocol=AT

Scan Code Set=2

Show Scan Codes, SHIFT+ESC=Exit: 5A F0 5A Classic Line:

;

Value Line:

Use this option to determine the Scan Codes the keyboard sends for each key. Press and release any key or combination of keys to view the Scan Codes sent. This option will display a maximum of 10 Scan Codes at a time. Some keys send different Scan Codes depending on the NumLock, Shift, Control, and Alt key states.

Cloning

F9

The ID Innovations Incorporated Classic Line Card Reader possesses the exceptional ability to configure another ID Innovations Incorporated Card Reader automatically. This option, known as Cloning, is extremely useful if you are configuring several Card Readers with the same setup. With Cloning, you setup the first Card Reader and copy its setup to additional Card Readers.

) Note: Cloning the Value Line readers is achieved through the use of the Universal Programmers Software. Lockout Cloned Reader Setup Mode: OFF Classic Line:

;

Value Line: ;

This option is used to lock out the setup mode on the cloned reader. Once the reader has been cloned the only method of changing the setup is by cloning a different setup into the reader, so use this option with caution. This option is useful for configuring readers to be used in an environment where the setup must not be changed. For the Value Line readers this option is listed as Lockout Keyboard Hotkeys, which will lockout any of the keyboard hotkeys listed on page 23. Press ENTER To Begin

Classic Line:

;

Value Line:

Press the Enter key to activate the cloning mode, from this point, all you need to do is unplug the keyboard and plug in the Card Reader to be configured. The cloning reader will then copy its settings to the other Card Reader, which will beep when it has been successfully cloned. Unplug the newly cloned Card Reader and repeat the process with the next reader. Once you have cloned all of the Card Readers, plug the keyboard back into the cloning reader and press the ESC key to exit Cloning.

) Note: Cloning the Value Line readers is achieved through the use of the Universal Programmers Software.

21

Page 22

Features

Reset All Defaults

F10

Reset All Defaults?: YES Classic Line:

;

Value Line: ;

Reset All Defaults returns the unit to initial factory settings.

Parsing

F11

The Value Line Readers have the built-in ability to Parse the Card data into a couple of different Parsings. A Parsing is an output format that is dependent on the Card data present. Simply define the Parsing conditions and then setup the individual fields that you wish to have output. If the card data does not match any defined parsing conditions the data will be output based on the current settings under F1 through F7, ie the default output mode.

) Note: A Field Parsing version of the Classic Line Magnetic Stripe Readers is also available upon request from ID Innovations Incorporated.

Parsing Number: Parsing 1 Classic Line:

Value Line: ;

The Value Line Card Readers have the ability to parse multiple card formats. This Combo Box is used to view the settings for each individual parsing. When you change the Parsing number in this Combo Box all other settings for the parsing are changed to reflect the current settings for the selected Parsing. Parsing Required Classic Line:

Value Line: ;

With this option checked the card data will only be transmitted to the computer if it matches one of the parsings. If you want to have the Reader transmit the data with the default output format as defined under F1-F7 be sure to leave this option unchecked. Data Match On: Off Classic Line:

Value Line: ;

This Combo Box defines the Track number that is to be used to match card data. This option can be set to Off, Track 1, Track 2, Track 3, or “No Match Needed Always Parse”. By setting this option to “No Match Needed Always Parse” the parsing will always be active for the current card data. If this option is set to a specific Track then the Parsing will only be active if the Match String is found on the Track and Offset specified. Match Offset: Start + 0 Classic Line:

Value Line: ;

This is used to specify the Offset for the beginning of the Match String. For example setting this option to Start + 0 indicates that the Match String must be found at the first character position of the card data. Likewise setting this option to End – 0 indicates that the Match String should be found at the end of the card data.

) Note: It is important to note that End – 0 is the LRC character of the specific Track.

Match String: Classic Line:

Value Line: ;

This is the string that is required to be present at the Match Offset on the Track specified for the Parsing to be activated. In addition to normal text characters you may enter any special characters required by specify the $ and the Hex value for the character. For a list of all of the HEX values and the keys that they represent, refer to Appendix-A, Special Characters Table. Field Definitions: Classic Line:

Value Line: ;

This List box contains a single line summary of each field defined within the current parsing. Simply click on the field listed and the settings for the field will be displayed to the right of the list box. A check by a field in the list box indicates that the field has been defined. Track: Off Classic Line:

Value Line: ;

This Combo Box is used to indicate on which Track the field can be found. By setting this option to Off the field is considered not defined for the Parsing. Starting Offset: Start + 0 Classic Line:

Value Line: ;

This setting is used to indicate the start of the field on the Track specified. 22

Page 23

Features

) Note: It is important to note that End – 0 is the LRC character of the specific Track.

Ending Offset: Start + 0

Value Line: ;

Classic Line:

This setting is used to indicate the end of the field on the Track specified.

) Note: It is important to note that End – 0 is the LRC character of the specific Track. Preamble:

Value Line: ;

Classic Line:

The Preamble is a string that is transmitted just prior to the actual field from the card. Postamble:

Value Line: ;

Classic Line:

The Postamble is a string that is transmitted just after the actual field from the card.

Exiting Setup Mode and Saving Changes (Classic Line Readers) Once you have configured the Card Reader, press the ESC key until you see the following prompt: Exit Setup? (Press ENTER): YES

Use the LEFT and RIGHT arrow keys to toggle between YES and NO, and ENTER once you make your selection. If you have made any changes to any of the settings, the Card Reader will prompt you to save changes. If you do not save changes, the Card Reader will discard all changes and display the following message: Setup Aborted - Changes Not Saved

If you save changes, the Card Reader will display a message indicating that all changes were saved. It is important to note that when changing the Keyboard Country the following message may be displayed: Setup Complete - Changes Saved Warning! International Chars May Differ For Keyboard Country

This warning is displayed when any of the following options contain international characters that may change from Keyboard Country to Keyboard Country: Termination String Preambles Postambles Send 6 Bit Field Separator '^' As Send 4 Bit Field Separator '=' As Send Track 3 Start Sentinel ';' As Send Track 3 Start Sentinel '%' As

) Note: A faster method of exiting setup mode is to use the ESC key in conjunction with the CTRL and ALT keys. Use CTRL ESC to exit setup mode and save all changes, and ALT ESC to exit setup mode without saving changes.

Programming Quick Keys (PS2 Style) In addition to the normal programming options the following Quick Keys have been added to quickly modify the output format and reset the unit to defaults.

Quick Reset - Left-Control, D, Right-Shift, and Backspace Classic Line:

;

Value Line: ;

In the event that you need to reset the unit back to factory defaults, the following special Quick Keys can be used. To reset the unit to defaults press and hold the Quick Reset keys. The Card Reader will produce a series of beeps indicating that it has entered programming mode. After a short delay you will hear a second series of beeps that indicate the Card Reader has exited programming mode and changes have been saved.

Transmit Speed Adjustment – Left-Control, 3, Right-Shift, and Enter Classic Line:

;

Value Line: ;

This can be used to adjust the data transmission speed from the card reader to the computer. Using this option adjusts the Transmit speed to a 6 on the Classic Line Card Readers or increments the Transmit Speed on the Value Line Readers. For the Value Line readers each use of this Quick Key sequence will slow down the Transmit Speed. Once the Transmit Speed is set to is slowest, another use of this key sequence will set the Transmit Speed to the fastest. 23

Page 24

Features

Quick Format To change the Track Output format, you can simply use one of the two predefined Quick Formatting options. These two options configure the Card Reader for some of the more popular credit card software packages. After pressing the Quick Keys for the formatting option the Card Reader will produce a series of beeps indicating that it has entered programming mode followed by a second series of beeps indicating the Card Reader has exited programming mode and changes have been saved. After the normal programming beeps the Card Reader will issue the appropriate number of beeps for the option selected. The Quick Format keys are as follows: Option 1 – Left-Control, 1, Right-Shift, and Enter Classic Line:

;

Value Line: ;

Selecting this option will instruct the Card Reader to output all tracks followed by a single Carriage Return. This mode is the factory default. The following is an example of the output format: <Track 1 Card Data><Track 2 Card Data><Track 3 Card Data><Carriage Return> Option 2 – Left-Control, 2, Right-Shift, and Enter Classic Line:

;

Value Line: ;

Selecting this option will instruct the Card Reader to output a Carriage Return after each Track of data. <Track 1 Card Data><Carriage Return> <Track 2 Card Data><Carriage Return> <Track 3 Card Data><Carriage Return>

OLE POS (OPOS) Toggle– Left-Control, 4, Right-Shift, and Enter Classic Line:

Value Line: ;

This option is used to Toggle the OLE POS (OPOS) output mode state. If OLE POS (OPOS) mode is currently Off using this key sequence will enable it and likewise if it is enabled it will disable this option.

Good Read Beep Toggle– Left-Control, Caps Lock, Right-Shift, and Enter Classic Line:

Value Line: ;

This option is used to Toggle the Good Read Beep. If Good Read Beep is on then it will be turned off and likewise if it is off it will be turned on.

24

Page 25

Appendices

25