Page 8
Features To install the Card Reader in Wand Emulation mode you must first configure the Card Reader for Wand Emulation and the proper segment sizes. In this mode of operation, the Card Reader can be plugged into the Wand port of a bar code decoder and the decoded Card Data is transmitted as Code 128 bar codes. In order to connect the Card Reader to the bar code port of a decoder you may have to use a simple cable adapter, for information on cable pin-outs see Appendix D.
) Note: Do not connect a keyboard to the Card Reader when operating in Wand Emulation mode. If you have a keyboard connected to the Card Reader when power is first turned on, the Card Reader will revert back to the Keyboard Wedge mode of operation. A keyboard should only be connected to the Card Reader after power is turned on, so that you may configure the Card Reader using the keyboard.
Installation – USB Adaptor If you have a Keyboard Wedge Magnetic Card Reader and you wish to install it on the USB ports of a computer, you can use the ID Innovations MultiMode USB Adaptor. The MultiMode USB Adaptor when used in conjunciton with a Keyboard Wedge Magnetic Stripe Reader provides all of the capability and performance of the ID Innovations MultiMode USB Direct Connect Magnetic Stripe Reader. For more information on this product visit our website at www.idinnovations.com.
Mounting The Card Reader The Card Reader can be mounted in one of two ways, using the Two Velcro strips included or inserting screws into the four threaded inserts on the bottom of the reader. However, if you choose to mount the unit using the threaded inserts, do not use a long screw in the insert by the cable. There is a socket located above the insert that will be damaged by a long screw.
) Note: It is recommended that you mount the Card Reader to avoid damaging the cable. Frequent bending of the cable can break the wires within it.
Operating The Card Reader The Card Reader is designed to read all of the standard magnetic card formats. To read a card, insert the card in the reader with the magnetic stripe facing the magnetic head in the Card Reader. The magnetic head is located on the same side as the LED on the top of the Card Reader. Slide the card through the Card Reader slot, with a smooth stroke, in either direction. When swiping the card through the Card Reader, the LED will turn off. Once you have completed swiping the entire card through the reader, the Card Reader will then set the LED to either green (for good read) or red (for no read). In addition to the green LED on a good read, the Card Reader will sound the buzzer to give you an audible indication that the card was successfully read, and the data is being transmitted to the computer.
Using The Universal Programmer Software to Configure The Card Reader This programming software is used for configuring ID Innovations USB Magnetic Card Readers and Keyboard Wedge (PS2 Style) Magnetic Card Readers. The main display of the Programmer allows you to view the settings of the configuration in an abbreviated format. In this format you can see all settings that have been changed from default. Many of the keyboard keys used to program the Keyboard Wedge (PS2 Style) Magnetic Card Readers can be used in the Univseral Programmers software. This allows customers with existing Keyboard Wedge (PS2 Style) Magnetic Card Readers to quickly become familiar with the Universal Programmers software. All settings available in the Keyboard Wedge (PS2 Style) Magnetic Card Readers can be found within the Universal Programmer Software, for explanations of each setting see page 11. In addition to allowing you to configure the Magnetic Card Readers the Univeral Programmer Software can be used to convert configuration of a Classic Line Reader for use in a Value Line Reader. Likewise you can take Value Line Programming and use it to program a Classic Line Reader.
) Note: To obtain a Free copy of the Universal Programmer software visit our Website at www.idinnovations.com. Using The Setup Mode To Configure The Card Reader (PS2 Style-Classic Line)
The Card Reader can be configured through the use of the computer keyboard. The Card Reader must be installed and powered to enter the setup mode. Once the unit is powered up, press and hold the following keys: 8
Page 9
Features Left-Control, Caps Lock, Right-Shift, and Backspace1 - or Left-Control, F1, Right-Shift, and Backspace2
) Note: To configure the Value Line Keyboard Wedge reader you will need to obtain a Free copy of the Universal
Programmer software from our Website at www.idinnovations.com. However several hot key sequences are available to configure the more frequently used options, see page 23 for more information.
Once you release the keys, the Card Reader will produce a series of beeps, change the LED to orange and display a message similar to the following on your display: F1-F10=Options, Use ARROW KEYS to Toggle/Move, ESC=Exit
To ensure that you have enough space on your command line for the Card Reader options to be displayed, we recommend that you either have your command prompt located at the root directory, or that you load an editor with a new file. This will allow the Card Reader to use most of the characters on your computer display. For example, in Windows load Windows Write and in OS/2 load the Notepad program. Setup is separated into many different categories ranging from "Interface" to "Cloning". The following is a list of function keys and the setup category for which they apply:
1This is a generic key sequence used to configure any ID Innovations' keyboard wedge device. 2This key sequence is used to configure ID Innovations' keyboard wedge Magnetic Stripe Readers only.
9
Page 10
Features Key F1
F2
F3 F4
F5
F6 F7
F8 F9 F10 F11
Category
Options
Keyboard Country Transmit Speed CTRL/Special Char Delay Send Numerics As Setup Mode Lockout Output Mode OLE OPOS Mode Serial (Baud Rate, Data Bits, Parity, Duplex, Data Format, Inverted Output, Intercharacter Delay, Caps Lock, Num Lock) Wand Emulation (Append Mode, Max Segment Size, Segment Output Delay) Firmware Version and Release Date Enable Tracks Magnetic Stripe Require Tracks Data Output Mode (Track Data, Field Data) Track Output Order Field Output Order EXP DATE Format Expiration Date Separator Char Send 6 Bit Field Separator '^' As Send 4 Bit Field Separator '=' As Send Track 2 Start Sentinel '%' As Send Track 3 Start Sentinel ';' As Send Track 3 Start Sentinel '%' As Send Track 3 Start Sentinel '!' As Send Start & End Sentinels Send LRC Character Send MSR Hardware Control Characters No Read Output String Track1, Track 2, Track 3 Stripping Editing ACCT, NAME, EXP DATE Stripping Magnetic Stripe Preamble Preambles Track1, Track2, Track 3 Preamble ACCT #, NAME, EXP DATE Preamble Send Pre/Postambles For Unread Tracks Magnetic Stripe Postamble Postambles Track1, Track 2, Track 3 Postamble ACCT #, NAME, EXP DATE Postamble Send Pre/Postambles For Unread Tracks Termination String Termination String Send Termination String Good Read Beep Buzzer/LED Beep Tone Beep Duration No Read LED Delay LED Power Save Mode Power Up Beep Firmware Version and Release Date Diagnostics Keyboard Information Show Scan Codes Lockout Cloned Reader Setup Mode Cloning Press ENTER To Begin Cloning Reset All Defaults Reset All Defaults? Parsing Options (see page xxx) Parsing
Classic Line
9 9 9 9 9 9 9
Interface
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
9 (upon request)
Value Line
9 9 9 9
9
9 9
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 (hotkeys) 9 9
For those categories which have more than one option, the UP and DOWN arrow and ENTER keys are used to move from one option to the next. In addition to the UP and DOWN arrow keys, the CTRL UP and CTRL DOWN arrow keys are used to move to the bottom and the top of the list. The following is a list of all special editing keys and a description of their function: Key Left Arrow, Right Arrow, Backspace & Space Bar Up & Down Arrow CTRL Up & CTRL Down Arrow Home & End ALT Backspace
CTRL + Keypad CTRL - Keypad CTRL F7
Description Toggles through the settings for the current option. Moves from one option to the previous or next within the category. Moves to the top or bottom of the category. Moves to the beginning or end of an input field. Toggles the output mode during configuration, between destructive backspace and non-destructive backspace. Defaults to non-destructive backspace. Increases transmit speed during setup. Decreases transmit speed during setup. Test the current Beep Tone and Beep Duration
10
Page 11
Features Key CTRL F10 ALT F10 CTRL Escape ALT Escape
Description Resets the current option to the default setting. Resets all options in current category to default settings. Exit configuration, saving changes. Exit configuration, without saving changes.
) Note: If you experience some character loss during setup, you may press the CTRL-(Keypad Minus) key to slow character transmission. To speed up character transmission, press the CTRL+(Keypad Plus) key.
) Note: After 5 minutes of inactivity (no key presses) the Card Reader will exit setup mode and save all changes. The following sections document all of the setup mode categories and the individual options within each category.
11
Page 12
Features
Interface
F1
Keyboard Country: UNITED STATES Classic Line:
;
Value Line: ;
The Keyboard Country option is used to inform the Card Reader of the keyboard country that should be used when transmitting card data.
) Note: If you set the Keyboard Country to BELGIUM, FRENCH, or GERMANY, then numeric data is sent faster by setting the Send Numerics As: option to NUMERIC KEYPAD KEYS.
The UNIVERSAL Keyboard Country is not actually a country setting. In this mode, the Card Reader sends most data to the computer as a series of ALT keypad sequences. For example, to transmit an "A" to the computer, the Card Reader performs the ALT 065 key sequence on the numeric keypad. It is important to note that this method of communication may not work with your computer hardware and software. It is possible that no data will appear on your computer if you set the Card Reader to output in this mode. If this is the case, you will have to reenter the setup mode and press F1, CTRL F10 and CTRL ESC on the Classic Line Keyboard Wedge models. For all other models simply run the Universal Programmer software and change the Keyboard Country back to the UNITED STATES default setting.
) Note: In order for the Keyboard Country changes to take effect, you must exit the setup mode and save changes.
Transmit Speed, 0=Fastest: Classic Line:
;
Value Line: ;
The Transmit speed option is used to control the speed at which card data is sent to the computer. In some instances the Card Reader may overrun the computer if this setting is too fast, or if the computer is busy performing some lengthy operation. Valid Values: Classic Line: (0-99) Value Line: (0-3)
) Note: If you are using an active USB Adaptor in conjunction with the Card Reader you will need to slow down the
Transmit Speed in order ensure that the USB Adaptor does not lose any keyboard data. USB Adaptors for the most part function properly when a person types on a keyboard but when used with a Point of Sale device such as a Magnetic Card Reader they are unable to keep up with the rate of speed that data is transmitted. Therefore you should set the Classic Line readers to a Transmit Speed of 15 and the Value Line readers to a Transmit Speed of 3.
CTRL/Special Char Delay (milliseconds): 50 Classic Line:
;
Value Line: ;
The CTRL/Special Char Delay is the amount of time the Card Reader will delay after sending a special character or a CTRL key sequence before sending the next character of data. The characters that are affected by this option are those that are non-printable. For a complete list of the characters, refer to Appendix-A, Special Characters Table. This feature is used to prevent overrunning the keyboard buffer when sending function keys and other non-data characters. Valid Values: Classic Line: (0-255)ms Value Line: (0=None,1=50ms) Send Numerics As: MAIN KEYBOARD KEYS Classic Line:
;
Value Line: ;
This option is used to indicate which numeric keys you want the Card Reader to use when transmitting magnetic stripe data to the computer. If this option is set to MAIN KEYBOARD KEYS, then all numeric data will be sent as numerics on the main keyboard. If this option is set to NUMERIC KEYPAD KEYS, then all numerics will be sent from the numeric keypad. Setup Mode Lockout: OFF Classic Line:
;
Value Line:
This option is used to allow you to lock out the setup mode until the unit is turned off and then powered back on. Once this option is activated and a magnetic stripe card is read, the setup mode will be locked out. This feature is used to prohibit unauthorized changes from being made to the reader's setup parameters. Output Mode: KEYBOARD WEDGE Classic Line:
;
Value Line:
This option is used to specify the output mode of the Card Reader. This option may be set to KEYBOARD WEDGE, SERIAL, WAND EMULATION, and KEYBOARD WEDGE - AT ONLY.
) Note: When using the USB version of ID Innovations Incorporated Magnetic Card Reader this option has no effect on Card Data transmission.
12
Page 13
Features KEYBOARD WEDGE In Keyboard Wedge mode the Card Reader will automatically detect the keyboard protocol of the host computer. The Card Reader should be installed as specified in the Installation - Keyboard Wedge section of this manual on page 7. SERIAL In Serial mode the Card Reader will transmit all data serially using the Serial settings below. In order for this mode typically requires you to use a Serial Converter, for more information see Installation - Serial on page 7. Plugging the Card Reader into a PC or TERMINAL with a keyboard attached places the reader in keyboard wedge mode, so that you may permanently change the Output Mode.
) Note: Prior to setting the Output Mode to SERIAL and connecting the Card Reader serially, configure all of the Serial settings to match your serial device. If you do not properly match the settings, the Card Reader will not output the data properly.
WAND EMULATION In Wand Emulation mode the Card Reader will transmit all data as bar code wand data. In this mode of operation, the Card Reader can be plugged into a Wand port of a bar code decoder and the decoded Card Data is transmitted as Code 128 bar codes. Plugging the Card Reader into a PC or TERMINAL with a keyboard attached places the reader in keyboard wedge mode. For information see Installation - Wand Emulation on page 7.
) Note: Prior to setting the Output Mode to WAND EMULATION and connecting the Card Reader to the bar code port of a decoder, properly configure all of the settings to match your decoders capabilities. If you do not properly match the settings, the Card Reader will not output the data properly.
KEYBOARD WEDGE - AT ONLY In Keyboard Wedge - AT ONLY mode the Card Reader must be connected to a AT compatible keyboard interface. In this mode the Card Reader will not autodetect the keyboard protocol of the host computer. The Card Reader should be installed as specified in the Installation - Keyboard Wedge section of this manual on page 7. OLE OPOS Mode: OFF
Value Line: ;
Classic Line:
This option is used to enable the OPOS output mode on Power Up for the Value Line Readers. This mode of output is for use with ID Innovations OPOS Control that is available for download at www.idinnovations.com Serial Baud Rate: 9600 Classic Line:
;
Value Line:
This option is used to control the speed of the serial communications. This option may be set to 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400. Serial Data Bits: 8 Classic Line:
;
Value Line:
This option is used to control the number of Data Bits used for each character of serial data. This option may be set to 7, or 8. Serial Parity: NONE Classic Line:
;
Value Line:
This option is used to control the Parity of the serial data that is transmitted. This option can be set to NONE, ODD, EVEN, MARK, or SPACE. Serial Duplex: FULL Classic Line:
;
Value Line:
This option controls the transmission of the serial data to the Terminal side of the Serial Converter. If this option is set to FULL, serial data is only transmitted to the HOST side of the serial connection. If this option is set to HALF, serial data is transmitted to both the HOST and the TERMINAL sides of the serial connection. Serial Data Format: ASCII Classic Line:
;
Value Line:
This option is used to set the format of the data when it is transmitted serially. With the default setting all data is transmitted as ASCII characters. If you set this option to SCAN CODES (PCTERM), all data is transmitted as scan codes. For example, the letter A would be transmitted as the scan code for the key on the keyboard that is used to generate the letter A. 13
Page 14
Features
) Note: The Keyboard Country setting effects the scan codes that are transmitted serially. Make sure that the Keyboard Country setting matches the Keyboard that you would normally use.
Inverted Serial Output: OFF Classic Line:
;
Value Line:
This option is used to control the format of the transmitted serial data. If you are directly connecting the Card Reader to a serial device with a powered serial port and are not using a Serial Converter, set this option to ON. Serial Intercharacter Delay: 1 Classic Line:
;
Value Line:
This option is used to control the amount of delay between each of the characters transmitted serially. This option is specified in Milliseconds and ranges from 0 to 50. Serial Caps Lock: OFF Classic Line:
;
Value Line:
When the Serial Data Format is set to SCAN CODES (PCTERM), this option controls the scan codes that are generated for the NUMERIC KEYPAD KEYS. When the Serial Data Format is set to ASCII this option has no effect. Serial Num Lock: ON Classic Line:
;
Value Line:
When the Serial Data Format is set to SCAN CODES (PCTERM), this option controls the scan codes that are generated for the alpha keys. When the Serial Data Format is set to ASCII this option has no effect. Wand Emulation Append Mode: OFF Classic Line:
;
Value Line:
The Code 128 bar code specification defines a FNC 2 character that can be used to concatenate two or more Code 128 bar codes. When a bar code with this special character is read, the decoder, stores the bar code and continues reading until a bar code without the special character is read. After reading a bar code without the special character all stored bar code data is transmitted to the host computer as if one bar code was read. This option is used to control the sending of the FNC 2 character. Wand Emulation Max Segment Size: 18 Classic Line:
;
Value Line:
This option is used to control the maximum number of characters of data that are transmitted in each segment. For example, if 30 characters of magnetic stripe data is read, two segments would be transmitted. The first segment size would be eighteen characters and the second would be the remaining twelve characters of data. Segment sizes can range from 1 to 99 characters.
) Note: Your bar code decoder will have a maximum number of characters that may appear in a Code 128 bar code. You should consult your bar code decoder manual to determine this number and set the Max Segment Size to the appropriate value.
Wand Emulation Segment Output Delay: 5 Classic Line:
;
Value Line:
This is the amount of time, the Card Reader waits before sending the next segment of the Magnetic Card data. This delay is used to give the receiving bar code reader enough time to process the previously transmitted segment. This input is in 10ths of a second and ranges from 0 to 30. Firmware Version and Release Date This option is an information only option, it displays the internal Firmware version and the Release Date of that firmware. This is useful when you wish to know the version and release date of an ID Innovations Incorporated Card Reader. When you cursor down to this option a message similar to the following will be displayed: :Firmware v1.1 Checksum=D3E2 12/22/94
14
Page 15
Features
Magnetic Stripe
F2
Enable Tracks: 1,2,3 Classic Line:
;
Value Line: ;
The Enable Tracks option is used to enable and disable specific tracks of information on the Card Reader. For example, it may be necessary in some applications to use only Track 2 information. In those cases, Track 2 would be the only track enabled. Require Tracks: NONE Classic Line:
;
Value Line: ;
The Require Tracks option is used to indicate the tracks that must be read in order to generate a good read. If this option is set to NONE, then any track read will be considered a good read. This feature is useful if your software requires specific tracks of data from the card. Data Output Mode: TRACK DATA Classic Line:
;
Value Line:
The Data Output Mode option is used to indicate the output of the Card Reader. If this option is set to TRACK DATA, the Card Reader will output the data one track at a time. If the option is set to FIELD DATA, the Card Reader will output the data as NAME, ACCT # and EXP DATE, as specified by the Field Output Order option (See Below). The NAME field is found only on track 1 encoded using format B, and is output in the following format: TITLE, FIRST NAME, LAST NAME. The ACCT # and EXP DATE can be found on either track 1 format b, or track 2. Both tracks must be adhere to ANSI/ISO specifications for financial transaction cards.
) Note: If this option is set to FIELD DATA and you attempt to read a card that does not contain the ACCT # and EXP DATE, the Card Reader will produce an error warble.
Track Output Order: 1,2,3 Classic Line:
;
Value Line: ;
The Track Output Order option controls the order in which the tracks read are output to the computer. The default for this option sends the tracks in 1, 2, 3 order.
)Note: This option has no effect if the Data Output Mode is set to FIELD DATA. Field Output Order: NAME, ACCT #, EXP DATE Classic Line:
;
Value Line:
The Field Output Order is used to specify the order of the magnetic stripe field data. When the Data Output Mode option is set to FIELD DATA, this option allows you to control the order and appearance of each of the fields output. The different settings for this option are as follows: NAME, ACCT #, EXP DATE NAME, EXP DATE, ACCT # ACCT #, NAME, EXP DATE ACCT #, EXP DATE, NAME EXP DATE, NAME, ACCT #
EXP DATE, ACCT #, NAME NAME, ACCT # NAME, EXP DATE ACCT #, EXP DATE ACCT #, NAME
EXP DATE, NAME EXP DATE, ACCT # NAME ACCT # EXP DATE
) Note: This option has no effect if the Data Output Mode is set to TRACK DATA. EXP DATE Format: MMYY Classic Line:
;
Value Line:
This option is used to control the format of the expiration date when the Data Output Mode is set to FIELD DATA. With this option, the date output can appear as follows: MMYY, YYMM, MM/YY, or YY/MM. You may use the Expiration Date Separator Char option to change the / character between the Month and Year. Expiration Date Separator Char: / DEC 47 HEX Classic Line:
;
Value Line:
This option is used to specify the separator character to be inserted between the Month and Year in the Expiration date when the Data Output Mode is set to FIELD DATA. For example, to insert a TAB between the Month and Year set the Expiration Date Separator Char to DEC 9 HEX 09.
) Note: Setting the Separator Character to a value from DEC 0 HEX 0 to DEC 31 HEX 1F will display an * as the separator character in the EXP DATE Format option.
15
Page 16
Features Send 6 Bit Field Separator '^' As ^ DEC 94 HEX 5E Classic Line:
;
Value Line: ;
This option allows you to change the separator character that is sent for tracks encoded with 6 bit data. You may specify any valid character for the Keyboard Country that is currently selected. This is a one character input field, press the key that represents the character or use an ALT keypad sequence to specify the character. For instance, to specify DEC 125, press and hold the ALT key while pressing and releasing the 1, 2 and 5 keys on the numeric keypad. Or you may select the character from the Combo box in the Universal Programmer to specify the character for the Value Line readers. This option has no effect if the Data Output Mode is set to FIELD DATA. Send 4 Bit Field Separator '=' As = DEC 61 HEX Classic Line:
;
Value Line: ;
This option allows you to change the separator character that is sent for tracks encoded with 4 bit data. You may specify any valid character for the Keyboard Country that is currently selected. This is a one character input field, press the key that represents the character or use an ALT keypad sequence to specify the character. For instance, to specify DEC 125, press and hold the ALT key while pressing and releasing the 1, 2 and 5 keys on the numeric keypad. Or you may select the character from the Combo box in the Universal Programmer to specify the character for the Value Line readers. This option has no effect if the Data Output Mode is set to FIELD DATA. Send Track 2 Start Sentinel '%' As + DEC 37 HEX Value Line: ;
Classic Line:
This option allows you to specify the character to substitute for the track 2 start sentinel so that you can distinguish track 2 data from track 1 data. This is a one character input field, select the character in the Combo box in the Universal Programmer to specify the character.
) Note: Changing the setting for this option will have no effect if the Send Start & End Sentinels option is OFF. Send Track 3 Start Sentinel ';' As + DEC 43 HEX Classic Line:
;
Value Line: ;
This option allows you to specify the character to substitute for the track 3 start sentinel so that you can distinguish track 3 data from track 2 data. This is a one character input field, press the key that represents the character or use an ALT keypad sequence to specify the character. Or you may select the character from the Combo box in the Universal Programmer to specify the character for the Value Line readers. This option has no effect if the Data Output Mode is set to FIELD DATA.
) Note: Changing the setting for this option will have no effect if the Send Start & End Sentinels option is OFF. Send Track 3 Start Sentinel '%' As % DEC 37 HEX Classic Line:
;
Value Line: ;
This option allows you to specify the character to substitute for the track 3 start sentinel so that you can distinguish track 3 data from track 1 data. This is a one character input field, press the key that represents the character or use an ALT keypad sequence to specify the character. Or you may select the character from the Combo box in the Universal Programmer to specify the character for the Value Line readers. This option has no effect if the Data Output Mode is set to FIELD DATA.
) Note: Changing the setting for this option will have no effect if the Send Start & End Sentinels option is OFF.
Send Track 3 Start Sentinel '!' As ! DEC 33 HEX Classic Line:
Value Line: ;
This option allows you to specify the character to substitute for the track 3 start sentinel so that you can distinguish track 3 data. . This is a one character input field, select the character in the Combo box in the Universal Programmer to specify the character.
) Note: Changing the setting for this option will have no effect if the Send Start & End Sentinels option is OFF.
16