Page 1
User’s Guide
Quick Check® 890 Quick Check ImageData
Barcode Verifier
°o © 8, Handucid.
PRODUCTS
Page 2
Disclaimer Hand Held Products, Inc. (“Hand Held Products”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Hand Held Products. Hand Held Products shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hand Held Products. ©2007-2008 Hand Held Products, Inc. All rights reserved. Web Address: www.handheld.com Quick Check® is a registered trademark of Hand Held Products, Inc. Windows® and the Windows logo are trademarks or registered trademarks of Microsoft Corporation. The Bluetooth® word mark and logos are owned by Bluetooth SIG, Inc. Note: Software screens included in this document are in English only and are included for reference only. They may be different from the screen that displays on your terminal.
Page 3
Table of Contents Chapter 1 - Getting Started Introduction........................................................................... 1-1 Unpacking the QC890 Verifier............................................. 1-1 QC890 Verifier Features....................................................... 1-1 Using the QC890 Verifier..................................................... 1-2 Scan Button........................................................................... 1-2 Scan Button LEDs.......................................................... 1-2 User LED Indications..................................................... 1-3 Physical Connections............................................................ 1-3 Specifications........................................................................ 1-4 Internal Battery ..................................................................... 1-4 Charging the Battery ...................................................... 1-4 Powering On the QC890 Verifier .................................. 1-4
Chapter 2 - Quick Check ImageData Quick Check ImageData....................................................... 2-1 System Requirements ........................................................... 2-1 Installation of Quick Check ImageData ............................... 2-1 Communication Interfaces.................................................... 2-1 USB Communication Interface ...................................... 2-2 USB COM Port Emulation............................................. 2-2 RS-232 Serial Communication Interface ....................... 2-3 RS-232 Selections .......................................................... 2-3 Bluetooth............................................................................... 2-3 Using the QC890 Verifier with Bluetooth Devices ....... 2-4 Enabling Your Device for Bluetooth.................................... 2-5 Enabling QCID for Bluetooth............................................... 2-6 Using Quick Check ImageData ............................................ 2-7 Help System.......................................................................... 2-8 i
Page 4
Chapter 3 - Using the Quick Check 890 Verifier System Scanning a Barcode Symbol Using the QC890 Verifier ...... 3-1 Scanning a Barcode Symbol Using Quick Check ImageData .................................................... 3-1 Calibrating the QC890 Verifier ............................................ 3-2 Scanning Properly Using a Pen/Mouse Wand...................... 3-3 Calibrating an External Pen/Mouse Wand ........................... 3-4 Scanning Properly Using the QC3800VE Linear Imager: ... 3-5 Calibration Log..................................................................... 3-6 Reflectometer Mode ............................................................. 3-6
Chapter 4 - Maintenance Cleaning the External Devices.............................................. 4-1 QC890 Verifier ..................................................................... 4-1 Recertification....................................................................... 4-1
Chapter 5 - Customer Support Technical Assistance ............................................................ 5-1 Online Technical Assistance .......................................... 5-2 For Further Information ................................................. 5-2 Product Service and Repair .................................................. 5-2 Online Product Service and Repair Assistance.............. 5-3 Limited Warranty.................................................................. 5-3
Appendix A - Apertures Pen/Mouse Wand Aperture Selection...................................A-1
Appendix B - Menu Setting Barcodes Resetting the Standard Product Defaults ..............................B-1 Illumination Timer................................................................B-1 Power Down Timer ..............................................................B-2
Appendix C - Symbology Defaults - Operation ii
Page 5
1 Getting Started Introduction The Quick Check® 890 Verifier System (QC890) is a professional quality control system for verifying the readability and standards compliance of printed linear barcode symbols. This verification system implements an integrated approach that consists of the QC890 Verifier unit and the Quick Check® ImageData (QCID) software. The QC890 system offers ease of use, stability and repeatability, flexibility, increased user features and control, and quality testing of the most common industry applications and symbologies.
Unpacking the QC890 Verifier After you open the shipping carton, take the following steps: • Check for damage during shipment. Report damage immediately to the carrier who delivered the carton. • Make sure the items in the carton match your order. • Save the shipping container for later storage or shipping. The standard accessories that should be included in your kit are: • • • • • • • • •
Quick Start Guide CD with QCID software and user documentation DC power supply with cord (includes adapters for different countries) Interface cables (USB and RS-232) Plastic gauge Metal ruler Reference test symbols Reflectance page Certificate of Conformance
QC890 Verifier Features The QC890 Verifier is a full-featured barcode verification system compatible with all major linear barcode symbologies. It is both a quick and easy-to-use pass/fail analyzer of barcode symbols and a powerful measuring tool for detailed testing of barcode symbols. The QC890 Verifier provides all of the information you need to interpret overall symbol quality.
Quick Check® 890 User’s Guide
1-1
Page 6
The verifier tests the following symbologies: Codabar
Micro PDF417
Code 11
MSI
Code 16K
PDF417
Code 39
Reduced Space Symbology (RSS-14, RSS Limited, RSS Expanded)
Code 49
Regular 2 of 5
Code 93
Straight 2 of 5 IATA
Code 128
Telepen
Interleaved 2 of 5
UPC/EAN
Using the QC890 Verifier The QC890 Verifier offers a choice of Automatic, 3, 5, 6, and 10 mil aperture settings. External devices (i.e., mouse wands, pen wands, and linear imagers) are available with apertures designed to match the most common X dimensions. Wands are available with apertures of 3 (Mouse Wand only), 5, 6, 10, and 20 (Mouse Wand only) mil. These aperture sizes correspond to those specified in ISO/IEC 15416 Barcode Print Quality Test Specification - Linear Symbols. The proper aperture should be selected based on the X dimension range shown in the table in the Pen/Mouse Wand Aperture Selection (page A-1) section. Choosing an inappropriate scanning aperture results in inaccurate quality measures. Too small an aperture may detect reflectance non-uniformities (spots and voids) that would not affect scanning with a "normal" aperture size. Too large an aperture will not be able to resolve individual elements of the symbol.
Scan Button The scan button on top of the unit wakes the unit from power down. A first press of the button turns on illumination and a second press activates reading capabilities.
Scan Button LEDs • Red LED - error conditions • Green LED - good symbols and configuration changes
1-2
Quick Check® 890 User’s Guide
Page 7
User LED Indications LED Indication
Cause
Green Solid Green Flash Red Flashing Orange Solid
Charging Good read Low battery Battery too low for unit to operate (plug in external power supply)
Audio Sound An audio signal (default ON) provides a quick indication if a scan passes or fails the current test. After a scan, one short, high pitch beep indicates that the symbol passes an appropriate group of tests, while one long, low pitch beep indicates that it fails.
Special Features Reflectometer Mode In the Reflectometer mode, the QC890 operates as a free-running reflectometer. See "Reflectometer Mode" on page 3-6 for additional information. Unrecognized Symbology Mode The QC890 analyzes bar/space patterns that are not decodable or are not among the unit’s available symbologies. This technical feature is useful for making contrast measurements, for which decoding is not necessary, on damaged or partial symbols, printer test patterns, and new or developing symbologies. We recommend this feature only be enabled for these purposes.
Physical Connections A DC power barrel on the back of the unit connects to a power supply for external power and battery charging. The DB9 port on the unit connects to the pen wand, mouse wand, or linear imager. Refer to "Scanning Properly Using the QC3800VE Linear Imager:" on page 3-5. If you are using any of these devices, refer to "Scanning Properly Using a Pen/Mouse Wand" on page 3-3 for additional information. The RJ45 ten pin connector provides the USB or RS-232 serial interface to the host. Refer to "USB Communication Interface" on page 2-2 and "RS-232 Serial Communication Interface" on page 2-3 for details on connecting your unit.
Quick Check® 890 User’s Guide
1-3
Page 8
Specifications Item
Specification
Dimensions
7” (18cm)W x 6”(15.cm)H x 5.4” (14cm)D
Weight
1 lb 8 oz (680 grams)
Temperature
Storage: -20° to 70°C Operational: 0° to 50°C
Humidity
20% to 95% RH non condensing
Battery
Built-in factory - Lithium Ion rechargeable
Internal Battery The battery is factory replaceable only. You must return your unit to Hand Held Products for replacement (see Technical Assistance on page 5-1).
Charging the Battery The battery may be in an unknown charge state at delivery. We recommend that you charge the battery for at least 2 hours prior to use. You may use the unit while charging the battery.
To charge the battery: 1.
Plug the power supply into the port on the back of the unit.
2.
Plug in the power supply to the AC main source.
The QC890 Verifier uses a rechargeable battery. The QC890 Verifier can be operated from the battery or power supply. With a properly charged battery, the unit operates for a minimum of 8 hours. When not in use, you can leave the unit connected to the charger.
Powering On the QC890 Verifier • If the power supply is attached and plugged into an AC source, the QC890 Verifier is on. • If the QC890 Verifier is attached to the USB host with power on, the verifier is on. • If the QC890 Verifier is operating using the battery, it shuts itself off after 15 minutes of inactivity to conserve battery power. Pressing the scan button on top of the unit one time powers up the unit from the power down mode.
1-4
Quick Check® 890 User’s Guide
Page 9
2 Quick Check ImageData Quick Check ImageData The Quick Check ImageData (QCID) program was designed for use in conjunction with the QC890 Verifier. Use of any other hardware devices with this program is not supported. Installation of the QCID software for your appropriate operating system is included on the CD-ROM that accompanied your verifier. The QCID is the graphical interface to the Quick Check 890 Verifier. The verification results can be saved for later reference.
System Requirements Windows: • • • • • • •
Microsoft Windows 98 Second Edition, 2000, Windows NT 4.0 or XP operating system Pentium 100Mhz (recommend 500Mhz and up) 64 MB RAM (recommended 128 MB and above) Application: 5 MB available hard disk space .NET framework: 110 MB of hard disk space required, 40 MB additional hard disk space required for installation (150 MB total) Any available COM or USB port or Bluetooth (supports SPP profiles) Microsoft compatible mouse
Windows Mobile 2003: • • • • •
Windows CE .NET 4.2 or Pocket PC 2003/2003 SE ARM4 processor 64 MB RAM (2MB RAM for the application) Any available COM port, Bluetooth (supports SPP profiles) Win 5.0 minimum 10mb
Installation of Quick Check ImageData To install the Quick Check ImageData, insert the CD and follow the instructions that appear.
Communication Interfaces The QC890 Verifier system supports the following interfaces: USB, RS-232, and Bluetooth®.
Quick Check® 890 User’s Guide
2-1
Page 10
USB Communication Interface For the USB interface, the Hand Held Products CDC-ACM driver must be installed prior to using the QC890 Verifier. This driver is copied to the following directory during install: <install location>\Drivers\USBCOMPortEmulation/hhpcdc.inf The default <install location> is C:\Program Files\Hand Held Products\Quick Check ImageData\drivers\USBCOMPortEmulation.
!
Review the file, readme.rtf, in the install location prior to running the QCID.
Connect the QC890 Verifier to the host as shown in the illustration below.
1 2
USB COM Port Emulation Scan the following barcode to program the QC890 Verifier to emulate an RS232-based COM Port. After connecting the QC890 Verifier and upon successful installation of the USB driver, the driver will use the next available COM Port. USB COM Port Emulation is the default interface for the QC890 Verifier.
* USB COM Port Emulation Note: No additional configuration (e.g., baud rate) is necessary.
2-2
Quick Check® 890 User’s Guide