Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 10

User Guide skeye.integral 2 HW 90200/V3 with Windows CE, pages 81 to 90

Pages 81 to 90 of 95

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Höft & Wessel skeye dart and Höft & Wessel skeye-integral

Page 81

TECHNICAL DATA

Internet Explorer

Weight:

approx. 500 g

Rules and Standards:

• CE conformity • German ElektroG and RoHS conformity

Safety class IP 54 is only guaranteed for the MDE device if the storage battery has been inserted and the interface cap is fitted.

1.00 • 06.10.2009 81

Page 82

TROUBLESHOOTING

Reset via Software

10

Troubleshooting In case there is no problem solution in this chapter • •

10.1 open our homepage (www.skeye.com) and change to the support forum http://forum.skeye.com) or contact our service line. The phone numbers can be found in chapter 11.5.

Reset via Software If an application does not react use the software to perform a restart. Select Start ⇒ Programs ⇒ System ⇒ Reset

NOTE! After a software reset, all data and settings will still be available on your MDE.

82

1.00 • 06.10.2009

Page 83

TROUBLESHOOTING

Reset via Hardware

10.2

Reset via Hardware If the touchscreen does not react or if you cannot switch on the device, press the reset button in the battery compartment of the device. To initiate a reset, proceed as follows: 1. Remove the battery block. 2. Press the reset key located underneath the battery block. Press the reset key carefully with low expenditure of force. You can do this using an opened paper clip or similar. 3. Insert the storage battery. The MDE switches on automatically.

Reset key

Fig. 54: MDE, reset

NOTE! After a hardware reset, all data and settings including the RAM data are deleted from you MDE.

1.00 • 06.10.2009 83

Page 84

TROUBLESHOOTING

An Internet Connection cannot be Established

10.3

An Internet Connection cannot be Established General:

84

Connections settings available?

Go to Start Settings Network Dial-up connection: There must be at least one connection created. If there is no connection available create a new one. Use either a modem or Wireless LAN.

Internet explorer connection OK?

Open the Internet Explorer. Open the View menu and select Internet Options. Select the Connections tab. If required, activate Use Auto Dial or Local Network. If required, activate Access the Internet using a proxy server and enter its address.

Is the Internet Explorer set to online?

Open the Internet Explorer and deactivate Work Offline in the File menu.

1.00 • 06.10.2009

Page 85

TROUBLESHOOTING

ActiveSync Connection Cannot be Established

10.4

ActiveSync Connection Cannot be Established

10.4.1

Checking the Connection of the Docking Station Ensure all cables and power supply units are connected properly. The green LED of the docking station indicates operation readiness.

10.4.2

Checking Connection Settings on the Desktop PC 1. Start ActiveSync on the desktop PC.

Fig. 55: ActiveSync | File

2. Select Connection Settings... in the File menu. The Connection settings window appears. (see next page)

1.00 • 06.10.2009 85

Page 86

TROUBLESHOOTING

ActiveSync Connection Cannot be Established

Activate this check box

Fig. 56: Connection Settings

3. Check the settings and change if required. 4. Click [OK] to confirm.

If your desktop PC is protected by a firewall note that those programs might prevent ActiveSync connections.

86

1.00 • 06.10.2009

Page 87

TROUBLESHOOTING

ActiveSync Connection Cannot be Established

10.4.3

Checking Registry Entries If you are unable to establish an ActiveSync connection between the MDE and the PC via the serial interface, Microsoft recommends checking that the following registry entries are present, and if not, editing the registry accordingly. CAUTION! Registry entries must only be changed by experienced and authorised users (administrator). Höft & Wessel as the producer does not accept any liability for damages (e.g. data loss, security vulnerability and so on) caused by registry changes.

Procedure for serial connections: •

On your PC call Start ⇒ Run ⇒ enter Regedit and execute.

•

Select HKEY_LOCAL_MACHINE or HKEY_CURRENT_USESR.

•

Open "Software\Microsoft\Windows CE Services". ⇒ Do you see the following entries? 1. [HKEY_LOCAL_MACHINE\Software\Microsoft\ Windows CE Services] "SerialPort"= <Valuet> "COM1" (or <Value> COM2) 2. [HKEY_CURRENT_USER\Software\Microsoft\Windows CE Services] "SerialBaudRate"=0001c200 (115200) (for 115 kbit/s) If the entries are not present, add them. Under HKEY_LOCAL_MACHINE click "Windows CE Services". Call Edit ⇒ New ⇒ String Value. Enter SerialPort (no quotation marks) Double-tap SerialPort. The Modify String window appears. Enter COM1 (or the COM port you use). Under HKEY_CURRENT_USER click Windows CE Services. Call Edit ⇒ New ⇒ DWORD Value. Enter SerialBaudrate (no quotation marks) Double-click SerialBaudRate to open the Modify DWORD Value window. Select Decimal and enter 115200 (no quotation marks). Close the registry editor. Restart your PC to enable changes.

1.00 • 06.10.2009 87

Page 88

ANNEX

Dialing Patterns

11

Annex

11.1

Dialing Patterns A dialing pattern defines the dialing location and dialing type. 1. Launch: Start ⇒ Settings ⇒ Control Panel The Control Panel menu appears. 2. Double-tap the Dialing symbol. The Dialing Properties window appears. Select Office or Private

Example: If you are in your office, the dialing patterns ensures that the number you will call is preceeded by a zero. If you are at home, no preceeding zero will be dialed. Use the [New] button to define new locations, use the [Remove] button to delete them. 3. Select either Office or Private and then tap [Edit].

•

88

If you only enter a “G” in all 3 rows, the telephone number you entered in the Telephone number field of the Make New Dial Up Connection window will be dialed exactly. In this case, the remaining fields for the country and area are of

1.00 • 06.10.2009

Page 89

ANNEX

Dialing Patterns no significance.

This is the simplest way of adjusting.

Fig. 57: Edit Dialing Patterns

•

If you enter additional entries, the telephone number will be composed of the additional entries for country code and area code.

The example shows dialing via outside line access. Here, the preceeding zero must be entered (0,G).

Fig. 58: Dialing pattern | Further settings

Here, the Country code and Area code fields are compared to the local settings (e.g. Office) and will only be dialed when the number of the location and the number of the destination are different.

If you are at a different location as entered in your local settings dialing problems might occur as the program always compares the number to be dialed with the local settings.

1.00 • 06.10.2009 89

Page 90

ANNEX

Taskbar / Symbol Description

11.2

Taskbar / Symbol Description The following symbols may appear in the taskbar: Symbol Meaning The storage battery is charged (see chapter 4.2) Less than 30% storage battery capacity Storage battery needs recharging Show keyboard Hide keyboard Call desktop (see chapter 3.2.10) ClickRight function (See chapter 3.2.7) Indicates an online connection Network connection established (see chapter 5.6). No network connection ActiveSync connection established (see chapter 8.2).

90

1.00 • 06.10.2009