Page 61

DATA BACKUP

SysBackup

NOTE! If you change your system settings e.g. after a new calibration of the touch you will have to perform a SysBackup. If not, the settings will no longer be available e.g. after a complete power off.

6.2.3

Restoring the Backup 1. Open the "SysBackup" program (see chapter 6.2.1). 2. Select [restore].

The message "Execute restore?" appears.

Fig. 37: Execute restore?

3. Click [Yes] to confirm the message. The backup will be imported. If there is no backup after a restart of if a backup is not required (e.g. after a warm start) the "Sysbackup" program searches all flash media (including the "FlashStorage" memory card) for the "autostat.exe" application. If such application is found it will be executed. There is an autostart mechanism independent from the registry as Sysbackup will always be automatically performed after the system start. Please note: RAM data will possibly be overwritten. All data will be updated to the state prevailing at the time of backup creation.

1.00 • 06.10.2009 61

Page 62

DATA BACKUP

SysBackup

6.2.4

Deleting a Backup 1. Open the "SysBackup" program (see chapter 6.2.1). 2. Tap [delete].

The message "Erase backup files?" appears.

Fig. 38: Erase backup files

3. Click [Yes] to confirm the message. The content of the \FlashStorage\SYSBAK directory will be deleted.

62

1.00 • 06.10.2009

Page 63

DOCKING STATION (STANDARD)

Connections of the Docking Station

7

Docking Station (standard) Slot for replacement storage battery

Slot for MDE with storage battery

The red LED shows the storage battery charging status.

Both yellow LEDs show communication.

The green LED shows that the docking station is ready Fig. 39: Docking station

7.1

Connections of the Docking Station Several connections can be found at the rear side of the docking station.

USB-Client to connect to the desktop PC using ActiveSync Power supply: Power supply unit connection Fig. 40: Docking station, connections

Serial interface

USB host to connect peripheral

1.00 • 06.10.2009 63

Page 64

DOCKING STATION (STANDARD)

Technical Data

7.2

Technical Data Casing:

• • •

Outside shell in impact-resistant plastic, self-extinguishing in accordance with UL94V-0 Baseplate in galvanised steel plate. Rear panel in semi-stainless steel

Slots:

• One slot for the MDE including storage battery. The following interfaces are used: - MDE device power supply, 9 V +/-5 %, 2.0 A - USB device - Serial interface • Charging slot for HW 19200 or HW 19201 storage battery

Ports & Connectors:

• Power supply: - Connection for HW 14200 power supply, DC voltage input Mini DC Power Jack ∅1,3 mm, 9 V / 2.5 A • Data interfaces: - Ethernet 10/100Base-T Ethernet socket

Displays:

• • •

Storage battery charging:

64

1.00 • 06.10.2009

-

USB host

USB 2.0 standard Low-power hub Used for interlinking of several ethernet docking stations

-

USB device

USB 2.0 standard Connection to PC possible; the HW 50251/V1 then logically represents itself as a USBnet Device (no support when using ActiveSync) Connection possible to USB host port on another ethernet docking station for interlinking purposes.

1 green LED and 2 yellow LEDs on the front panel signal docking station operating status 1 red LED for replacement storage battery charging process 1 green + 1 yellow LED integrated in ethernet socket, signal ethernet connection made (green, left) and current data transmission (yellow, right)

• • •

In accordance with manufacturer's instructions Charging in MDE: controlled by MDE charging electronics Charging in replacement battery charging slot: controlled by ethernet docking station charging electronics

•

When inserted rechargeable battery is recognised, first charging using constant current charging, subsequently

Page 65

DOCKING STATION (STANDARD)

Technical Data switches over to constant voltage charging. • Charging start with reduced charging current for rechargeable batteries with low voltage. • Automatic switch-off of charging process when rechargeable battery fully charged. • Automatic switch-off if battery overheats. • Charging duration: approx. 2.5 h (HW 19200) or approx. 5 h (HW 19201) Surrounding conditions:

• • •

Rules and Standards:

• CE conformity • German ElektroG and RoHS conformity

Dimensions:

L 14.5 x W 17.3 x H 9.2

Weight:

approx. 900 g (without storage battery)

Operate only in enclosed rooms Ensure good ventilation is available Operating temperature: limit values: 0 °C to +40 °C, recommended range: 10 °C to +30 °C, • Storage temperature: -20 °C to +60 °C • Humidity: up to 85 % (non-condensing)

1.00 • 06.10.2009 65

Page 66

DOCKING STATION (STANDARD)

Charging the storage battery

7.3

Charging the storage battery The docking station provides charging and operating current for the MDE when inserted, and also provides a charging function for a replacement storage battery. Charging batteries in the MDE: • If the MDE device cannot be switched on despite an inserted storage battery, or if the MDE device display shows a weak storage battery voltage, the storage battery should be recharged. • A message on the MDE's screen indicates that the battery is in need of charging. • To charge the battery, place the MDE (including battery) in the docking station (connected to power) • If the LED on the MDE is red, the MDE has been placed correctly in the docking station. • In addition, the charging process is indicated on the MDE’s screen. Replacement battery: • If you wish to charge a replacement battery, place the battery in the docking station (connected to power). • If the red LED in front of the replacement battery compartment is on, the battery has been inserted correctly in the docking station and will be charged

End of charging process

MDE: • If the red charging control LED of the MDE changes from permanent shining to flashing, the storage battery is fully recharged. • The MDE is now ready for operation again. Replacement battery: • If the red LED in front of the replacement battery compartment is just flashing, the replacement battery is fully charged.

Charging duration

66

• A completely discharged battery will be recharged in approx. 2.5 to 3 hours. If the storage battery is not fully discharged, the recharging period is shortened accordingly. For a HW 19201 storage battery, the charging time doubles.

1.00 • 06.10.2009

Page 67

DOCKING STATION (STANDARD)

Connecting the Docking Station to the Desktop PC

The red charging control LED at MDE and docking station may • be off • shine permanently or • flash It may also indicate possible failures by • blinking − When flashing, the LED is activated only for a short time. − When blinking, the on and off times of the LED are nearly equal. To differ between blinking and flashing, a closer look at the LED is required. However, this is only necessary when the charging process does not start immediately, i.e. the charging control LED does not shine permanently or when the charging process takes remarkably long.

7.4

Connecting the Docking Station to the Desktop PC PC

Power supply USB cable Fig. 41: Connection docking station PC

1. Establish a connection between the docking station and the desktop PC at an USB port. 2. Connect the power supply unit to the docking station. 3. Insert the mains plug into the socket.

1.00 • 06.10.2009 67

Page 68

COMMUNICATION/DATA EXCHANGE

General Information on Exchanging Data with the Desktop PC

8

Communication/Data Exchange

8.1

General Information on Exchanging Data with the Desktop PC You can connect your MDE to a desktop PC using a docking station. You may either use the USB client connection or the serial connection. Please note that you have to perform the corresponding settings in ActiveSync when you change the connection type (see chapter 8.4). To establish a connection between the MDE and a desktop PC install the ActiveSync program on your desktop PC (see chapter 8.2.2). Then you can establish a connection between the devices and setup a partnership between the MDE and the desktop PC.

68

1.00 • 06.10.2009

Page 69

COMMUNICATION/DATA EXCHANGE

Exchanging Data using ActiveSync

8.2

Exchanging Data using ActiveSync Using the ActiveSync program you can perform the following tasks (between your desktop PC and your MDE):

8.2.1

•

Save and restore your MDE data

•

Add and remove programs on your MDE

•

Synchronise files

•

Transfer and copy files

System Requirements for the ActiveSync Program: •

Desktop PC with a 486/33DX processor or higher

•

Microsoft Windows NT Workstation 4.0 or Windows 95 (or higher).

•

8 MB main memory (12 MB recommended) for Windows 95 or higher and 16 MB main memory (32 MB recommended) for Windows NT Workstation.

•

Hard disk with 10 to 50 MB free memory space (the actual demand depends on the selected functions and the current system configuration).

•

Available 9-pole serial connection for remote data transmission

•

VGA graphics adapter board or graphics adapter board with higher resolution (SVGA 256 colours recommended)

1.00 • 06.10.2009 69

Page 70

COMMUNICATION/DATA EXCHANGE

Exchanging Data using ActiveSync

8.2.2

Installing ActiveSync on Your Desktop PC 1. Start the Internet-Explorer on your desktop PC (see chapter 8). 2. Enter the following Internet address: "www.microsoft.com". 3. Under Product Ressources select Downloads. 4. Enter ActiveSync into the search mask and click Go. 5. Click the download link of the required ActiveSync software version. 6. In the following window click Download. 7. Follow the instructions on screen to install ActiveSync. 8. Restart your desktop PC. 9. After the restart the Establish connection window appears. Here, you are prompted to establish a connection to your MDE.

70

1.00 • 06.10.2009