Page 45

Table 3 shows the format of the CSV file: • Columns 1-11 are generated by the QueTel software and are not taken from the Asset ID tag. The remaining columns are directly taken from the Asset ID EEPROM. • Columns 3-8 contain the data you entered manually in step 2 on page 27. • Columns 9-11 (asset manufacturer, model and serial number) contain data if you selected No to the question Scan Asset ID (Y/N) in step 3 on page 28. If you answered Yes to this question, these fields would be blank. • Columns 34-38 are the five custom data fields in the user area as described in 2.1, “The Asset ID EEPROM” on page 4. However, the five custom field labels are not retrieved by the software. Table 3. Format of the CSV file

Column

Data

Type

1

Datestamp

Date

2

Timestamp

Date

3

Inventory taker name/ID

Char width 50

4

Location

Char width 50

5

Building

Char width 50

6

Room

Char width 50

7

Barcode

Char width 50

8

Description Code

Char width 50

9

Asset Manufacturer

Char width 50

10

Asset Model Number

Char width 50

11

Asset Serial Number

Char width 50

12

Tag ID

Char width 50

13

Tag Manufacturer

Char width 50

14

Tag Model Number

Char width 50

15

Tag Serial Number

Char width 50

16

User Name

Char width 50

17

User Department

Char width 50

18

User Location

Char width 50

Chapter 3. Asset ID partner solutions

33

Page 46

34

Column

Data

Type

19

User Phone Number

Char width 50

20

User Position

Char width 50

21

Lease Start Date

Date

22

Lease End Date

Date

23

Lease Term

Integer

24

Lease Amount

Currency

25

Lessor

Char width 50

26

Asset Purchase Date

Date

27

Asset Last Inventoried Date

Date

28

Asset Warranty End Date

Date

29

Asset Warranty Duration

Integer

30

Asset Purchase Amount

Currency

31

Asset Number

Char width 50

32

Profile Image Date

Date

33

Profile Image Name

Char width 50

34

User-Defined Value 1

Char width 50

35

User-Defined Value 2

Char width 50

36

User-Defined Value 3

Char width 50

37

User-Defined Value 4

Char width 50

38

User-Defined Value 5

Char width 50

39

UUID

Char width 50

40

MAC Address 1

Char width 50

41

MAC Address 2

Char width 50

42

CPU Family 1

Char width 50

43

CPU Family 2

Char width 50

44

CPU Speed 1

Char width 50

45

CPU Speed 2

Char width 50

Implementing Asset ID

Page 47

Column

Data

Type

46

Memory Size 1

Char width 50

47

Memory Size 2

Char width 50

48

Memory Size 3

Char width 50

49

Memory Size 4

Char width 50

50

FDD1

Char width 50

51

FDD2

Char width 50

52

IDE Type 1

Char width 50

53

IDE Type 2

Char width 50

54

IDE Size 1

Char width 50

55

IDE Size 2

Char width 50

3.2 QueTel Asset TraQ QueTel’s end-to-end PC asset-tracking solution is Asset TraQ . Asset TraQ provides all the necessary tools including a database, to inventory your RFID-enabled PCs. The Asset TraQ application is a comprehensive asset system that can even track non-RFID assets. The functions include: • Search capability, Perform searches based on multiple criteria. • Report writer, Present information in an organized format either on paper, screen or digital file. • Import module, Map and import data from other sources. • Export module, Export a file to common file formats using selected search criteria. • Global replace, Identify specific data records and data elements to change. • Password and security module, Set up users and groups with varying authority to view, read, and write data. • Purge capability, Identify a class of records to remove or retire and store as archive status. • Record history, Each time a record is changed, the action is recorded in the history section.

Chapter 3. Asset ID partner solutions

35

Page 48

The Asset TraQ solution comprises the following components: • Asset TraQ software application • Symbol PDT (Portable Data Terminal) 3100 or 6100 • Peripheral hardware to connect PDT to PC via serial port • HID AMH 100 RFID Reader • PDT software application • User’s guide For more information about this product, visit: http://www.QueTel.com/docs/rfid/assetidflyer.htm To contact QueTel, see: http://www.QueTel.com/docs/corporate/contactdw.htm

3.2.1 Before you begin In our test environment we installed Asset TraQ on an IBM 300PL (Model 6862) running Windows 2000 Professional. We used the Symbol Technologies PDT 6100 and the HID Corporation AMH100 reader. We installed the 60-day demo version of the software, which can be obtained from: ftp://ftp.quetel.com/pub Note: If you do plan to download the software, you will require the Symbol PDT 3100 (or compatible Symbol PDT) and an HID AMH100. QueTel has an evaluation program where these devices can be rented for a small fee. Contact QueTel for information about this program. Programming the Symbol PDT can be equated to loading an operating system on a PC. The following installation instructions assumes you have these items: • The file ASSET_ID.EXE downloaded from ftp://ftp.quetel.com/pub • A suitable Symbol PDT and peripheral accessories to connect to a PC. • The HID AMH100. • A license key valid for the day you are installing the software. A demonstration key is available by contacting QueTel as described in a dialog box during the application installation. • Local administrative rights if using Windows NT or Windows 2000.

36

Implementing Asset ID

Page 49

Notes: 1. The installation procedure using the downloadable demonstration version is different compared to when you purchase the Asset ID Starter Kit from QueTel. When you purchase the kit, the Symbol PDT is preprogrammed and the application software is supplied on CD-ROM. 2. The size of installed IDE hard disks may be incorrectly reported. For SCSI hard disks, you will not receive any size information. 3. On ThinkPads, the memory amount returned is incorrect (usually half of the actual value). This is a problem with ThinkPad BIOS and Asset ID area and plans are to fix this in future versions of the ThinkPad BIOS. Check http://www.pc.ibm.com/support for details.

3.2.2 Installation procedure To install Asset TraQ, do the following: 1. Attach your Symbol serial connector/charger from the PDT base or mini-docking unit/charger to a COM port on your PC. We have used COM1. Ensure that there is power to the charging unit. 2. On your PC change the serial port settings to the following values. On our PC300 with Windows 2000 installed, we followed these steps: a. Right-click My Computer and click Properties. b. Click the Hardware tab. c. Select Device Manager. d. Expand Ports (COM & LPT). e. Double-click Communications Port (COM1). f. Click the Port Settings tab. g. Make the changes as listed in Table 4, then click OK. h. Close Device Manager. Table 4. COM1 settings

Setting

Value

Bits per second

38400

Data Bits

7

Parity odd

Stop Bits

1

Flow Control

Xon / Xoff

3. Locate and run ASSET_ID.EXE. 4. Complete the installation process by following the prompts.

Chapter 3. Asset ID partner solutions

37

Page 50

5. Restart your computer when prompted. 6. Log back in with Administrator rights. 7. Launch Asset TraQ. 8. You will be prompted for a registration number. This must be obtained from QueTel. If you do not have a registration number there is a number to call provided in the dialog box. Enter your registration number and then click Register Now. 9. You will be prompted with a logon ID and password. Both the logon ID and password are “quetel”. 10.Since we are using the downloadable demo version, you will be shown database with three demo records.

Figure 18. Main window after logon

11.Close this database. Note: You must close the database to activate the additional menu items that you need, including the Handheld item. 12.Click Handheld > Load Program. Figure 19 appears.

38

Implementing Asset ID

Page 51

Figure 19. Configuring the COM port

13.Change the settings to match Figure 19. 14.Follow the instructions in Figure 19. Click OK when you have finished these steps. 15.If loaded successfully you will see Status 0000 on your PDT. Follow the steps in Figure 20 to cold boot the PDT.

Figure 20. Cold booting the PDT

16.Once your PDT has been rebooted, click OK to close the dialog box.

Chapter 3. Asset ID partner solutions

39

Page 52

17.Take the Symbol unit out of its charging / serial connection interface. The PDT may turn on automatically when removed from the charging unit. You will be prompted with the QueTel information. Press Enter on the PDT to continue. 18.Attach the AMH100 to the Symbol PDT. 19.Power-on the Symbol PDT by pressing the small on/off button or by pressing the large yellow buttons on the side. Press the Enter button to continue through the two welcome screens. 20.At one prompt you will be asked for date and time. Press the Clear button to change this. 21.Enter the current date by using the numbers on the keypad and then press the Enter button. This will bring you down to the time field. 22.Enter the current time using a 24-hour clock and then press the Enter button. 23.You will be prompted if these date and time values are correct. If they are press the Enter button. 24.You will now see the main menu: ** Main Menu ** 1:Collect New Items 2:Inv On-Hand Items 3:RFID View/Modify 4:RFID Only 5:Utility Menu >> VSELECT

ITEM or CLR

3.2.3 Asset TraQ and the Asset ID Starter Kit The engine that runs the Symbol PDT for Asset TraQ is the same one used for the Asset ID Starter Kit. Hence the following similarities: • The steps to view and modify Asset ID data are the same. Refer to 3.1.2, “Viewing and updating the Asset ID data” on page 22 for details. • The steps to perform inventory data collection are the same. Refer to 3.1.3, “Collecting inventory” on page 27 for details. • The process to upload data is the same on the PDT side but slightly different on the PC side. We step you through the upload process in the following section.

40

Implementing Asset ID

Page 53

3.2.4 Uploading information to the PC Once the information is captured (as described in 3.1.3, “Collecting inventory” on page 27), it is uploaded to our PC into the Asset TraQ software. 1. Turn off your Symbol PDT. 2. Detach the AMH100 from the Symbol PDT. 3. Plug the Symbol PDT into the peripheral that connects your PDT to your PC’s serial port. 4. Launch Asset TraQ 5. Log in with user ID and password (“quetel” for both). The Asset TraQ main window now appears. 6. On the PDT, highlight option 5, Utility Menu and press the Enter button. ** Utility Menu ** 1:Send Data to PC 2:Erase Data on HH 3:Load Lookup Tables 4:Erase Tables on HH 5:Set Date and Time 6:System Help VSELECT ITEM or CLR 7. Highlight option 1, Send Data to PC then press the Enter button. 8. You will be prompted with the communication settings. These settings should already be correct, however, do not press the Enter button yet. 9. In Asset TraQ on the PC, close the database window. The Handheld pull-down menu now becomes active:

With the database closed, the Handheld pulldown menu is now active. Figure 21. Asset TraQ main window with database closed

10.Click Handheld > Receive Data. Figure 22 appears.

Chapter 3. Asset ID partner solutions

41