Table 3 shows the format of the CSV file: • Columns 1-11 are generated by the QueTel software and are not taken from the Asset ID tag. The remaining columns are directly taken from the Asset ID EEPROM. • Columns 3-8 contain the data you entered manually in step 2 on page 27. • Columns 9-11 (asset manufacturer, model and serial number) contain data if you selected No to the question Scan Asset ID (Y/N) in step 3 on page 28. If you answered Yes to this question, these fields would be blank. • Columns 34-38 are the five custom data fields in the user area as described in 2.1, “The Asset ID EEPROM” on page 4. However, the five custom field labels are not retrieved by the software. Table 3. Format of the CSV file
Column
Data
Type
1
Datestamp
Date
2
Timestamp
Date
3
Inventory taker name/ID
Char width 50
4
Location
Char width 50
5
Building
Char width 50
6
Room
Char width 50
7
Barcode
Char width 50
8
Description Code
Char width 50
9
Asset Manufacturer
Char width 50
10
Asset Model Number
Char width 50
11
Asset Serial Number
Char width 50
12
Tag ID
Char width 50
13
Tag Manufacturer
Char width 50
14
Tag Model Number
Char width 50
15
Tag Serial Number
Char width 50
16
User Name
Char width 50
17
User Department
Char width 50
18
User Location
Char width 50
Chapter 3. Asset ID partner solutions
33
Page 46
34
Column
Data
Type
19
User Phone Number
Char width 50
20
User Position
Char width 50
21
Lease Start Date
Date
22
Lease End Date
Date
23
Lease Term
Integer
24
Lease Amount
Currency
25
Lessor
Char width 50
26
Asset Purchase Date
Date
27
Asset Last Inventoried Date
Date
28
Asset Warranty End Date
Date
29
Asset Warranty Duration
Integer
30
Asset Purchase Amount
Currency
31
Asset Number
Char width 50
32
Profile Image Date
Date
33
Profile Image Name
Char width 50
34
User-Defined Value 1
Char width 50
35
User-Defined Value 2
Char width 50
36
User-Defined Value 3
Char width 50
37
User-Defined Value 4
Char width 50
38
User-Defined Value 5
Char width 50
39
UUID
Char width 50
40
MAC Address 1
Char width 50
41
MAC Address 2
Char width 50
42
CPU Family 1
Char width 50
43
CPU Family 2
Char width 50
44
CPU Speed 1
Char width 50
45
CPU Speed 2
Char width 50
Implementing Asset ID
Page 47
Column
Data
Type
46
Memory Size 1
Char width 50
47
Memory Size 2
Char width 50
48
Memory Size 3
Char width 50
49
Memory Size 4
Char width 50
50
FDD1
Char width 50
51
FDD2
Char width 50
52
IDE Type 1
Char width 50
53
IDE Type 2
Char width 50
54
IDE Size 1
Char width 50
55
IDE Size 2
Char width 50
3.2 QueTel Asset TraQ QueTel’s end-to-end PC asset-tracking solution is Asset TraQ . Asset TraQ provides all the necessary tools including a database, to inventory your RFID-enabled PCs. The Asset TraQ application is a comprehensive asset system that can even track non-RFID assets. The functions include: • Search capability, Perform searches based on multiple criteria. • Report writer, Present information in an organized format either on paper, screen or digital file. • Import module, Map and import data from other sources. • Export module, Export a file to common file formats using selected search criteria. • Global replace, Identify specific data records and data elements to change. • Password and security module, Set up users and groups with varying authority to view, read, and write data. • Purge capability, Identify a class of records to remove or retire and store as archive status. • Record history, Each time a record is changed, the action is recorded in the history section.
Chapter 3. Asset ID partner solutions
35
Page 48
The Asset TraQ solution comprises the following components: • Asset TraQ software application • Symbol PDT (Portable Data Terminal) 3100 or 6100 • Peripheral hardware to connect PDT to PC via serial port • HID AMH 100 RFID Reader • PDT software application • User’s guide For more information about this product, visit: http://www.QueTel.com/docs/rfid/assetidflyer.htm To contact QueTel, see: http://www.QueTel.com/docs/corporate/contactdw.htm
3.2.1 Before you begin In our test environment we installed Asset TraQ on an IBM 300PL (Model 6862) running Windows 2000 Professional. We used the Symbol Technologies PDT 6100 and the HID Corporation AMH100 reader. We installed the 60-day demo version of the software, which can be obtained from: ftp://ftp.quetel.com/pub Note: If you do plan to download the software, you will require the Symbol PDT 3100 (or compatible Symbol PDT) and an HID AMH100. QueTel has an evaluation program where these devices can be rented for a small fee. Contact QueTel for information about this program. Programming the Symbol PDT can be equated to loading an operating system on a PC. The following installation instructions assumes you have these items: • The file ASSET_ID.EXE downloaded from ftp://ftp.quetel.com/pub • A suitable Symbol PDT and peripheral accessories to connect to a PC. • The HID AMH100. • A license key valid for the day you are installing the software. A demonstration key is available by contacting QueTel as described in a dialog box during the application installation. • Local administrative rights if using Windows NT or Windows 2000.
36
Implementing Asset ID
Page 49
Notes: 1. The installation procedure using the downloadable demonstration version is different compared to when you purchase the Asset ID Starter Kit from QueTel. When you purchase the kit, the Symbol PDT is preprogrammed and the application software is supplied on CD-ROM. 2. The size of installed IDE hard disks may be incorrectly reported. For SCSI hard disks, you will not receive any size information. 3. On ThinkPads, the memory amount returned is incorrect (usually half of the actual value). This is a problem with ThinkPad BIOS and Asset ID area and plans are to fix this in future versions of the ThinkPad BIOS. Check http://www.pc.ibm.com/support for details.
3.2.2 Installation procedure To install Asset TraQ, do the following: 1. Attach your Symbol serial connector/charger from the PDT base or mini-docking unit/charger to a COM port on your PC. We have used COM1. Ensure that there is power to the charging unit. 2. On your PC change the serial port settings to the following values. On our PC300 with Windows 2000 installed, we followed these steps: a. Right-click My Computer and click Properties. b. Click the Hardware tab. c. Select Device Manager. d. Expand Ports (COM & LPT). e. Double-click Communications Port (COM1). f. Click the Port Settings tab. g. Make the changes as listed in Table 4, then click OK. h. Close Device Manager. Table 4. COM1 settings
Setting
Value
Bits per second
38400
Data Bits
7
Parity odd
Stop Bits
1
Flow Control
Xon / Xoff
3. Locate and run ASSET_ID.EXE. 4. Complete the installation process by following the prompts.
Chapter 3. Asset ID partner solutions
37
Page 50
5. Restart your computer when prompted. 6. Log back in with Administrator rights. 7. Launch Asset TraQ. 8. You will be prompted for a registration number. This must be obtained from QueTel. If you do not have a registration number there is a number to call provided in the dialog box. Enter your registration number and then click Register Now. 9. You will be prompted with a logon ID and password. Both the logon ID and password are “quetel”. 10.Since we are using the downloadable demo version, you will be shown database with three demo records.
Figure 18. Main window after logon
11.Close this database. Note: You must close the database to activate the additional menu items that you need, including the Handheld item. 12.Click Handheld > Load Program. Figure 19 appears.
38
Implementing Asset ID
Page 51
Figure 19. Configuring the COM port
13.Change the settings to match Figure 19. 14.Follow the instructions in Figure 19. Click OK when you have finished these steps. 15.If loaded successfully you will see Status 0000 on your PDT. Follow the steps in Figure 20 to cold boot the PDT.
Figure 20. Cold booting the PDT
16.Once your PDT has been rebooted, click OK to close the dialog box.
Chapter 3. Asset ID partner solutions
39
Page 52
17.Take the Symbol unit out of its charging / serial connection interface. The PDT may turn on automatically when removed from the charging unit. You will be prompted with the QueTel information. Press Enter on the PDT to continue. 18.Attach the AMH100 to the Symbol PDT. 19.Power-on the Symbol PDT by pressing the small on/off button or by pressing the large yellow buttons on the side. Press the Enter button to continue through the two welcome screens. 20.At one prompt you will be asked for date and time. Press the Clear button to change this. 21.Enter the current date by using the numbers on the keypad and then press the Enter button. This will bring you down to the time field. 22.Enter the current time using a 24-hour clock and then press the Enter button. 23.You will be prompted if these date and time values are correct. If they are press the Enter button. 24.You will now see the main menu: ** Main Menu ** 1:Collect New Items 2:Inv On-Hand Items 3:RFID View/Modify 4:RFID Only 5:Utility Menu >> VSELECT
ITEM or CLR
3.2.3 Asset TraQ and the Asset ID Starter Kit The engine that runs the Symbol PDT for Asset TraQ is the same one used for the Asset ID Starter Kit. Hence the following similarities: • The steps to view and modify Asset ID data are the same. Refer to 3.1.2, “Viewing and updating the Asset ID data” on page 22 for details. • The steps to perform inventory data collection are the same. Refer to 3.1.3, “Collecting inventory” on page 27 for details. • The process to upload data is the same on the PDT side but slightly different on the PC side. We step you through the upload process in the following section.
40
Implementing Asset ID
Page 53
3.2.4 Uploading information to the PC Once the information is captured (as described in 3.1.3, “Collecting inventory” on page 27), it is uploaded to our PC into the Asset TraQ software. 1. Turn off your Symbol PDT. 2. Detach the AMH100 from the Symbol PDT. 3. Plug the Symbol PDT into the peripheral that connects your PDT to your PC’s serial port. 4. Launch Asset TraQ 5. Log in with user ID and password (“quetel” for both). The Asset TraQ main window now appears. 6. On the PDT, highlight option 5, Utility Menu and press the Enter button. ** Utility Menu ** 1:Send Data to PC 2:Erase Data on HH 3:Load Lookup Tables 4:Erase Tables on HH 5:Set Date and Time 6:System Help VSELECT ITEM or CLR 7. Highlight option 1, Send Data to PC then press the Enter button. 8. You will be prompted with the communication settings. These settings should already be correct, however, do not press the Enter button yet. 9. In Asset TraQ on the PC, close the database window. The Handheld pull-down menu now becomes active:
With the database closed, the Handheld pulldown menu is now active. Figure 21. Asset TraQ main window with database closed
10.Click Handheld > Receive Data. Figure 22 appears.
Chapter 3. Asset ID partner solutions