Chapter 1. Introduction Asset ID is radio frequency identification (RFID) technology from IBM that makes it easier for you to roll out new PCs and ThinkPads to users, to perform inventory, and to improve the security of your systems. Recent models of IBM PC 300PL, NetVista, and IntelliStation workstations and ThinkPad notebooks have an electrically erasable programmable read-only memory (EEPROM) chip that can be read from or written to without having to open the system case or even unpack it from its shipping box. Depending on the system and attached monitor, Asset ID gives you access to the following system information: • System model and serial number • CPU serial numbers • Memory installed and DIMM serial numbers • Hard disk sizes and serial numbers • Attached monitor model and serial number Without any additional hardware, you can do the following: • Write user data to the EEPROM using tools such as IBM Director and LCCM, then read that data back later for analysis. The data will then be stored in the systems and can also be automatically uploaded to the company-wide asset database. • Completely automate the rollout of new operating platforms specific to that user or system, using LCCM. To take advantage of the RFID capabilities, you can add a handheld reader. This reader comprises three parts: a barcode reader from Symbol Technologies, an RF adapter from HID Corporation, and software that runs on the barcode reader and on a Windows PC. With an RFID handheld reader and application software, you can: • Automate rollout of new systems. You can read the serial number and MAC address of each system and write the name of the user to the EEPROM before the box is unpacked. Once the system is cabled up, you can then configure LCCM to remotely power up the system and install the operating system and user applications. • Perform inventory of existing systems, even if they are powered off. You can read the system information in the EEPROM simply by holding the RFID scanner in front of the system, regardless of whether the
© Copyright IBM Corp. 2001
1
Page 14
machine is powered on or not. You can then transfer this information into your inventory database for further analysis. IBM has partnered with a number of hardware and application vendors to provide a complete Asset ID solution. In this redbook, we describe products from: • Symbol Technologies, makers of a range of programmable handheld barcode scanners. • HID Corporation, makers of the AMH100 handheld RF reader, which connects to the Symbol scanner. • QueTel Corporation, makers of Asset ID software Asset TraQ and the Asset ID Starter Kit.
2
Implementing Asset ID
Page 15
Chapter 2. Components Asset ID is made up of components both internal to PCs and ThinkPads and external to system units. The Asset ID subsystem includes three components: • An EEPROM non-volatile memory module, integrated on the system planar. • A passive antenna, attached inside the system unit. • A radio frequency (RF) reader, an external device. One implementation, as shown in Figure 2, uses the combination of a handheld programmable barcode scanner (known as a portable data terminal or PDT) and an RF reader. There are generally three types of reader: handheld, portal, and panel. The EEPROM and antenna are collectively called the tag. System Interface to applications such as LCCM, UM Services, and IBM Director
EEPROM
RF interface
HID Corporation RF reader
Passive RF antenna Symbol Technologies barcode scanner Figure 2. Asset ID EEPROM and passive antenna
Typically, the system interface of the EEPROM will be connected to a bus within the asset to allow access to the data from the system. Since the tag is integrated into the asset, this tag is called an integrated tag . If the tag has no system bus interface to the EEPROM, the tag is called a non-integrated tag and is also known as a legacy tag . These non-integrated tags are typically used to provide the RF capability for existing assets. All Asset ID implementations in IBM systems use integrated tags.
© Copyright IBM Corp. 2001
3
Page 16
2.1 The Asset ID EEPROM The Asset ID EEPROM is a non-volatile memory space. Information stored there remains intact even after a system power failure. It can be read from and written to using either of two interfaces: • The system bus interface is used by the system BIOS and application software running on the system to store and retrieve asset information on the EEPROM. LCCM, IBM Director and UM Services are three examples of an application that writes to the Asset ID EEPROM through the system bus interface. LCCM is discussed in 4.1, “LANClient Control Manager” on page 50. • The RF interface connects to the antenna where the asset information can be read and written by an RF reader. When the system is switched on, the EEPROM draws its power from the system power supply. When the system is not switched on, the EEPROM draws its power from the RF field generated by the RF reader. This allows you to access the tag even when the system is not connected to a power outlet, such as inside a shipping carton. The EEPROM holds 1 KB of data broken up into three areas as listed in Table 1. The only area that the RF interface has write access to is the user area. Table 1. EEPROM contents
Area
Size
Access via the RF interface
Access via the system interface
Serial
248 bytes
Read
Read/Write
User
248 bytes
Read/Write
Read/Write
Configuration
248 bytes
Read
Read/Write
2.1.1 Serial area The serial area holds all the serial numbers of the system. This area can be written and read through the system interface but can only be read by the RF interface. Serial numbers stored in this area are: • System model and serial number • CPUs • Memory DIMMs
4
Implementing Asset ID
Page 17
• CD-ROMs • Power supplies • Disk drives • Diskette drive • System planar • Monitor model and serial number on supported monitors and systems
2.1.2 Configuration area The configuration area contains details about the basic system configuration. It is updated automatically by the system BIOS during the initial power-on sequence when it detects a new component. The BIOS will compare the system state with the configuration area and make corrections if differences exist (for example, a new memory DIMM or CPU is added). Data stored in this area is: • System UUID • MAC address of the integrated network controller • CPU type and speed • Memory: Number and sizes of installed DIMMs • IDE devices: type and size • PCI devices: location, vendor and device IDs, class and subclass • Display size and resolution (ThinkPad LCD only)
2.1.3 User area The user area consists mostly of personal data. This area is the only one that can be updated via the RF interface. The fields are separated into groups as follows: • User information: - Name - Department - Location - Phone number - Position • Lease information: - Start and end dates - Lease term - Lease amount - Lessor name
Chapter 2. Components
5
Page 18
• Asset information: - Purchase date - Date of last inventory - Warranty end date - Warranty duration - Amount - Asset identification number • LCCM image profile data: - Image name - Image date • Network connection information: - System name - Login userID - Number of network cards - IP addresses - Default gateway - Subnet masks • Five custom fields: - Label (for each field) - Data (for each field)
2.2 The RF antenna The antenna is a passive RF receiver/transmitter and therefore does not have any power source of its own. It is designed to read data from the EEPROM and write data to the EEPROM using the energy generated by the RF field from the reader. In operation, the reader initiates communications by generating a 125 kHz RF carrier signal modulated with information to be sent to the antenna and EEPROM (collectively called the tag). The reader then generates an unmodulated carrier and waits for a response from the tag. The tag uses backscatter modulation (BSM) to respond to the reader. In this technique, the tag sends information to the reader by modulating the field generated by the reader and reflecting it back. The tag inside the PC is not capable of generating any RF signal on its own. It can only respond to the field generated by a reader designed for use with RFID.
6
Implementing Asset ID
Page 19
2.3 The RF reader/writer The RF reader/writer is an external device that communicates with the Asset ID tag via the RF antenna. A reader is required to read or write data using the RF interface. The three types of reader are: handheld, portal, and panel. • A handheld reader is a reader that is battery operated and designed for portable use. These devices are typically designed to be lightweight with an antenna that is easily positioned within close proximity to a tag. Applications for these readers include deployment or inventory of assets throughout the enterprise. An example is the combination of the Symbol Corporation Portable Data Terminal (PDT) and HID Corporation AMH100 handheld reader as discussed below. This portable combination lets you read from and write to the Asset ID tag plus upload that data to a PC-based application via the PDT’s serial interface. The PDT is completely programmable via the serial interface. Typically, the PDT software is downloaded during the installation of the asset software on the PC it is connected to. • Panel readers are usually mounted on a wall or placed on a counter near a protected area. This type of reader is primarily used in a paperless, property pass application. • Portal readers are devices that have a more permanent installation, typically located at a doorway or portal to a protected area. Portal readers are positioned so as to require the asset to be carried through the reader field to exit or enter the area. Regardless of the reader type, since power for the EEPROM is obtained from the RF signal generated by the reader, it is possible to read and write the EEPROM with the asset still in the shipping box.
2.3.1 Symbol Technologies Portable Data Terminal The Symbol PDT is a handheld programmable terminal with built-in barcode scanner. RFID applications such as QueTel Asset TraQ and the Asset ID Starter Kit work with both the Symbol 6100 and the 8-line Symbol 3100 PDTs. Product information about these devices can be found at: http://www.symbol.com/products/mobile_computers/mobile_kb_pdt_3100.html http://www.symbol.com/products/mobile_computers/mobile_kb_pdt_6100.html
Chapter 2. Components
7
Page 20
Symbol 6100
Symbol 3100
Figure 3. Symbol PDTs (6100 and 3100)
These PDTs are available with a variety of installed memory from 640 KB to 7.2 MB. The extra memory lets you store more Asset ID data from clients without having to upload to a PC. Using the following values, you can determine how many systems you can record in the available RAM: • QueTel application: 500 KB • Each Asset ID record: 550 bytes This means, for example, the 640 KB model of the 3100 can hold data for up to 254 systems: 640 KB - 500 KB = 140 KB / 550 bytes = 254 systems The Symbol cradle, power supply and 25-9 pin null modem cable shown in Figure 4 is part of the QueTel Asset ID Starter Kit as described in 3.1, “QueTel Asset ID Starter Kit” on page 16. You can also order each item separately. This combination provides the following functions:
Œ Recharger and cradle to store the PDT Connectivity to the host PC for data transfer and programming of the PDT Ž Space to recharge an optional second battery
8
Implementing Asset ID
Page 21
Ž Œ
Figure 4. Recharger and host connection cradle
Also available is a cable and power supply combination, as shown in Figure 5, that performs the same functions, but without the bulk of the cradle. These components are ordered separately.
Figure 5. Recharger and host connection kit
Chapter 2. Components
9
Page 22
2.3.2 HID Corporation AMH100 RF Reader
Figure 6. HID Corporation AMH100 RF Reader
The AMH100 plugs into the Symbol PDT to provide a read/write interface to the Asset ID tag. The connector provides an RS-232 interface. Using a converter the AMH100 can be connected directly to a desktop PC or ThinkPad via the serial port. This does, however, also require an AC adapter for the AMH100 as the PC serial port cannot power the unit directly. Product information about this device can be found at: http://www.proxtrak.com/products/handrdr.html
2.4 Supported systems Selected IBM desktop PCs have both the Asset ID EEPROM and the RF antenna installed inside the system unit. In most instances, the RF antenna is located behind the front bezel of the system unit (see Figure 8 on page 13). Some systems (for example, some ThinkPad models) only have the EEPROM installed as standard, but the antenna is available as an option. The location of the antenna is also indicated by an Asset ID “bull’s-eye” sticker on the outside of the packing box in which the desktop system was shipped:
10
Implementing Asset ID
Page 23
Asset ID
Figure 7. Asset ID sticker on packing box
The purpose of the sticker, as well as showing you that the system is enabled for Asset ID, is that it indicates the location of the RF antenna and where you should point the RF reader to communicate with the Asset ID subsystem. Tip: If you are having problems scanning a system while it’s still in its shipping carton, try the following: • Rotate the AMH100 RF Reader 90°. If the system is a mini-tower instead of a desktop, the antenna will be in a different orientation. • Move the RF Reader closer or further away from the box. • Try the area around the bull’s-eye sticker, not just on the sticker. ThinkPad systems have the EEPROM installed on the system planar but typically, the RF antenna is an easily installable option. This means that you cannot use the RF interface of the EEPROM until you install the option. You can use the system interface with tools such as LCCM, however. The following systems have Asset ID capabilities. This means that, except where noted, they have both the EEPROM and the RF antenna installed: IBM PC 300PL: • Model 6862 • Model 6892 • Model 6584 • Model 6594 • Model 6565 IntelliStation: • M Pro Model 6889 • E Pro Model 6893 • Z Pro Model 6865
Chapter 2. Components
11
Page 24
NetVista: • A40p Model 6649 • A40p Model 6579 • A40p Model 6841 • S40p Model 6646 ThinkPad: • T20, Models 2647 and 2648 (requires RF Antenna option 08K6064) • A20 Models 2628 and 2633 (requires RF Antenna option 08K6064) The list of the latest supported systems can be found at: http://www.pc.ibm.com/ww/assetid/systems.html You can also get details about the level of Asset ID support from spec sheets at one of the following addresses: http://www.pc.ibm.com/us/netvista/library.html http://www.pc.ibm.com/us/thinkpad/tech_library.html http://www.pc.ibm.com/us/intellistation/tech_library.html In some other desktop systems (for example, NetVista A40 and S40 systems), the Asset ID EEPROM is installed but there is no option for an antenna and thus it cannot be RFID enabled in the future. This means you can use tools such as LCCM and UM Services to read and write to the EEPROM but you cannot use a handheld reader to access Asset ID data via the RF interface. The antenna option for the ThinkPads, once installed, should not normally be removed. In some systems, such as ThinkPad T20s, the antenna cannot physically be removed once it is installed. On the ThinkPad A20 systems, if you do decide to remove the antenna, make sure you disable antenna detection (using the RFID Security menu accessible from the Config menu in the System BIOS) before you remove the antenna. If you do not, you will get a POST error 0193 which will prevent the system from starting until the antenna is reinstalled. The Asset ID antenna is in different locations depending on the system, as indicated in Figure 8. You should hold the AMH100 RF Reader about 3-5 inches (8-13 cm) in front of these areas to get proper communication with the antenna. Note: The face of the AMH100 RF Reader should be parallel to the antenna to get a proper reading. If the reader is 90° out, for example, you may not be able to establish communications with the antenna. If you are scanning
12
Implementing Asset ID
Page 25
systems while they are still in their packing boxes, you should determine, from Figure 8, what the antenna orientation is.
300PL 6565 ThinkPad T2x 300PL 6862
NetVista 6579 NetVista 6841 ThinkPad A2x Figure 8. Asset ID antenna locations on various IBM systems
2.5 Software There are a number of software products that work with Asset ID. These include: • LANClient Control Manager (LCCM) is an IBM product that is used to remotely install software on client machines. On Asset ID-enabled client machines, LCCM can read user information from the EEPROM to make a rollout totally automatic. LCCM can also write information to the EEPROM for use by other applications. See 4.1, “LANClient Control Manager” on page 50 and the LCCM Web page: http://www.pc.ibm.com/us/desktop/lccm • Software Delivery Assistant (SDA) is an IBM product that lets you easily roll out sets of applications to a particular business groups. See 4.2, “Integrating Software Delivery Assistant with Asset ID” on page 87 and the SDA Web page: http://www.pc.ibm.com/ww/software/applications/sda • UM Services, Netfinity Director 2.12 and IBM Director 2.2. These IBM management products can also read from and write to the EEPROM and queries can be made against that data from a large group of systems for
Chapter 2. Components
13
Page 26
analysis. See Chapter 5, “Integrating with IBM Director” on page 111 and the UM Services and Netfinity Director/IBM Director Web pages: http://www.pc.ibm.com/ww/software/applications/ums/index.html http://www.pc.ibm.com/ww/eserver/xseries/systems_management/ • Tivoli products, with the use of the Universal Manageability Services plus module for Tivoli Framework, allow you to access the Asset ID data from your Tivoli console. See Chapter 6, “Integrating Asset ID with Tivoli Inventory” on page 127. • The Asset ID Starter Kit from QueTel, an IBM Business Partner, is a combination of a handheld RF reader/writer plus software to access the Asset ID data via the RF interface into the EEPROM. The Asset ID Starter Kit is an excellent entry-product for inventory and rollout tasks. See 3.1, “QueTel Asset ID Starter Kit” on page 16 and the Asset ID Starter Kit Web page: http://www.quetel.com/docs/rfid/starterkit.htm • Asset TraQ from QueTel is their full-function asset management tool, which also interfaces with the RF interface of the EEPROM using a handheld scanner or other RF device (portal, panel, etc.). See 3.2, “QueTel Asset TraQ” on page 35 and the Asset TraQ Web page: http://www.quetel.com/docs/rfid/assetidflyer.htm
2.6 Support The Web page with product information for Asset ID is: http://www.pc.ibm.com/ww/assetid You can obtain technical support for Asset ID and other UM products (LCCM and Netfinity Director for example), both via e-mail and via a moderated forum. Access both of these at: http://www.pc.ibm.com/ww/solutions/enterprise/support/
14
Implementing Asset ID