Page 19
The TT8500 may display a screen titled TT8500 Secure Setup. This is a special menu used by key loading facilities to load the secure encryption keys used by the firmware. (See Apéndice - Carga de la clave de codificación beginning on page E-A-1 for further information.) If you don’t want to use the Secure Setup, touch the Other Setup button. The TT8500 displays the message, “ THIS UNIT IS NOT SETUP!” Touch the pad to enter the regular setup mode. The TT8500 includes a Test menu within the Setup menu that allows you to test the various functions of the terminal. The following charts show the options you can change and functions you can test using the Setup and Test menus.
Setup Menu Submenu
Description
TCP/IP
This displays the TCP/IP Wired Options menu. Press the Change button to the left of Host IP Address, Host Port, Default Gateway, TT8500 IP Address, or Subnet Mask to change any of these settings. A keypad appears that allows you to enter the new setting. Press Enter to accept the new setting and return to the TCP/IP Wired Options menu. The MAC address of the Ethernet interface is displayed on the TCP/IP Wired Options menu, but is factory-assigned and cannot be changed. When Connect On Startup is checked, the TT8500 connects to the Ethernet host on power up. The TCP/IP defaults are: Host IP Address: 192.168.1.200 Host Port: 1010 Default Gateway: DHCP TT8800 IP Address: DHCP Subnet Mask: DCHP MAC Address: 00:10:20:xx:xx:xx Connect on Startup: Checked Press Accept or Cancel to return to the main Setup menu.
Transaction Team™ TT8500
I-9
Page 20
Setup Menu Submenu
Description
Host
Note: Your system auto-configures for whatever cable you use: RS-232, RS-485, Ethernet, or USB. When connected via RS-232/RS-485 cable: The menu allows you to set the RS-232 Handshaking: Enable CTS holdoff option, the port Baud Rate, and the Extended passthrough mode: On at Startup option. The defaults are: Enable CTS holdoff: Checked (does not send to host unless CTS is active from the host) Baud Rate: 38400 On at startup: Unchecked When connected via USB cable: No configuration is required, although the menu for configuration in RS-232 mode is shown. Press Accept or Cancel to return to the main Setup menu.
Lock
Enter a password to insure that the setup can only be changed by someone who has the password. (There is no default password.) Once a password is entered and confirmed, it is necessary to have the password to perform any future changes to the setup. Do not forget your password! If you do, you will not be able to change the setup. Cancel exits to the Setup menu. Clear deletes all characters entered. Enter saves the information and returns to the Setup menu.
Sound
This selection toggles the sound effects on and off. When the sound is on, PIN numbers make a sound when pressed, and the MSR makes a sound when a card is swiped. The default is Sound on.
Time
This displays an analog clock. Adjust the clock by increasing or decreasing the hours and minutes. The seconds can be zeroed by pressing the zero button, then pressing Done. The default is 12:00.
I-10
Transaction Team™ TT8500
Page 21
Setup Menu Submenu
Description
Calib
Displays the pad calibration screen. (The TT8500 is calibrated at the factory, and should not need recalibration in most circumstances.) Carefully press the very center of each of the four crosses to calibrate the pad. Press Accept or Cancel to return to the main Setup menu.
Keys
Lists any encryption key loaded into the secure memory of the unit. The keys can only be changed from a special key loading screen.
Aux
This menu allows you to set the RS-232 Handshaking: Enable CTS holdoff option, and the port Baud Rate for the auxiliary port. The defaults are: Enable CTS holdoff: Checked (does not send to host unless CTS is active from the host) Baud Rate: 38400 Press Accept or Cancel to return to the main Setup menu.
Transaction Team™ TT8500
I-11
Page 22
Setup Menu Submenu
Description
Route
The Port Routing Config menu displays the port routing configuration for the input ports.
Note: The Ethernet input port option is only displayed when the hardware is installed. • Selecting CMD indicates that the TT8500 should treat input on that row’s particular input port as TT8500 firmware script command data. If the data does not conform to a TT8500 firmware command, the data is ignored and discarded. Selecting CMD automatically disables all other routing options for that particular input port. • Selecting one or more of the other four options for an input port causes all input data on that port to be routed. Therefore, the data is re-transmitted as output data to the checked port(s). • If any re-transmission routing is selected for an input port, the command processing for that input port is disabled. Press Accept or Cancel to return to the main Setup menu. Example 1 (Default settings): All ports treat input data as command data. TCP/IP: [ X] CMD
I-12
[ ] TCP/IP
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
Main RS-232: [ X] CMD [ ] TCP/IP
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
Aux RS-232: [ X] CMD [ ] TCP/IP
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
USB: [ X] CMD
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
[ ] TCP/IP
Transaction Team™ TT8500
Page 23
Setup Menu Submenu
Description
Route, continued
Example 2: All ethernet command input is turned off. All main port input is passed through to the aux port. USB and aux port input is treated as fimware commands. TCP/IP: [ ] CMD [ ] TCP/IP
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
Main RS-232: [ ] CMD [ ] TCP/IP
[ ] MAIN
[X ] AUX
[ ] USB
[ ] RF
Aux RS-232: [ X] CMD [ ] TCP/IP
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
USB: [ X] CMD
[ ] MAIN
[ ] AUX
[ ] USB
[ ] RF
[ ] TCP/IP
Contrast
Adjust the TT8500 LCD brightness with the Contrast slider. (This setting is not changed by any reset operations.)
Accept
Saves all setting changes made since entering the Setup menu. These settings are used whenever the unit powers up. After the settings are saved, the unit returns to normal operation.
Cancel
The unit returns to normal operation without changing any settings.
Transaction Team™ TT8500
I-13
Page 24
Setup Menu Submenu
Description
Reset Options
Displays the Reset Options menu: Ethernet Parameters: When checked, this resets the settings for TCP/IP (Ethernet) parameters to the factory defaults. Other System Setup Params: When checked, this resets the settings for Host and Aux ports, Sound on/off, and Routing Options to the factory defaults. User Data (Scripts and Images): When checked, this resets the User Data Bank in flash memory to the factory defaults. This erases any scripts or bitmap images that have been saved in the unit.
Note: If you reset the User Data, but not the Other System Setup Params, check the Route options (page 12) to be sure you can communicate with the device to load a new script (in case the previously loaded script changed the Route options). Accept Reset: Causes the settings for the selected items to be reset to their factory defaults and returns to the main Setup menu. (After returning to the main Setup menu, the factory default values can be modified as needed.) Cancel Reset: Returns to the main Setup menu without changing/resetting any settings.
I-14
Transaction Team™ TT8500
Page 25
Test Menu Test
Submenu
Description
Display
Displays various fonts and test patterns. Touch each pattern as it appears to check the LCD screen. When the test is done, you are returned to the Test menu.
Note: If the screen is not touched during the test, the display cycles through the test screens, then returns to the Test Menu. Pad
Allows you to test the touch pad by drawing or writing on it. The coordinates of each point are displayed as the screen is touched. Press Quit to return to the Test menu.
Audio
Plays music to test the TT8500 speaker. Touch the pad to abort the test. When the test is complete, you are returned to the Test menu.
PIN
Displays a PIN pad. If a PIN pad key is loaded, you can enter a PIN pad number. Enter or Cancel exits to the Test menu. Clear deletes all digits entered. Undo erases the last digit.
AMT
Allows you to enter a number in order to test the number pad. Enter or Cancel exits to the Test menu. Clear deletes all digits entered. Undo erases the last digit.
HEX
Allows you to enter a hexadecimal number in order to test the number pad. Enter or Cancel exits to the Test menu. Clear deletes all digits entered. Undo erases the last digit.
SIG
Allows you to enter a signature. Done or Clear exits to the Test menu.
MSR
Allows you to swipe magnetic card and display track information. Touching the pad exits to the Test menu.
Data
Displays the contents of user memory. Touching the pad exits to the Test menu.
Done
Returns to the Setup menu.
Transaction Team™ TT8500
I-15
Page 26
Software Development Kit Hand Held Products offers documents and software designed to assist software application developers. The Transaction Team 8500 SDK allows developers to conveniently integrate signature transaction, credit, debit, surveys, and graphical advertisement capabilities into their applications. To download a copy of the SDK and/or the associated documentation, go to www.handheld.com. Click on Services & Support and click on Developer Resource Area and select the TT8500 product line. Install Software Development Kit This option provides an SDK for use with the TT8500. The SDK provides a software tool (TTAdvantage88) to be used in conjunction with the appropriate software compiler or integrated development environment that enables you to develop your own software applications for use with the TT8500. To install the SDK, turn on your computer and run the setup program using the following procedure: 1. Extract all the TT8500 SDK install files from the zip file you downloaded. 2. Double click on the setup.exe file. The main TT8500 SDK setup program appears. 3. Select SDK installation option. The SDK setup program appears. 4. Follow the menu steps until completion is indicated.
NOTE: In order for you to develop your own applications, the appropriate software compiler (Microsoft C/C++) or Integrated Development Environment (Visual Basic, Visual C++, etc.) is required. This compiler is NOT provided in the TT8500 SDK.
Summary of SDK Components TTAdvantage88 TTAdvantage88 is a Visual Basic Add-In tool that is used to develop a script application that resides and executes on the TT8500. TTAdvantage88 can also be used to develop a VB mode application to reside and execute on your host system. Visual Basic 6.0 is required to use this tool. Functions • Tools for integrating command buttons, signature capture boxes, graphics, MSR data capture, text boxes, list boxes, option buttons, labels, and check boxes onto TT8500 terminal screens.
I-16
Transaction Team™ TT8500