Page 61

%&-

-

'"- SCANTEAM 8300/8310 MICR Line Formatter Standard MICR Output Data Formats

Programming Menu Format #

MICR Data Format Transmitted to the Host

00

<ENTIRE MICR LINE UN-EDITED (RAW MICR)> S Includes spaces and symbols S Field format rules not verified

02

<TRANSIT #>T<ACCOUNT #>A<CHECK SERIAL #> S Account #: space, dash, On Us

03

<TRANSIT #>T<14 DIGIT ACCOUNT #>A<6 DIGIT CHECK SERIAL #> S Account #: no spaces or dashes, zero filled, right justified S Check #: zero filled, right justified

04

<TRANSIT #>T<ACCOUNT #>A<CHECK SERIAL #> S Account #: includes spaces and dashes, but no On Us

98

<ENTIRE MICR LINE UN-EDITED (RAW MICR)> S Includes spaces and symbols S Field format rules verified <ENTIRE MICR LINE UN-EDITED (RAW MICR)> S Includes spaces and symbols S Field format rules not verified S A question mark (?) is sent for unreadable characters

99

5.4 Output Data Formatter

!'&"'&

!'&"'& !

& &! ' '* "!$& &! &! ! )-+ - - - '* "!$& - 5–4

MICR Data Processing

Page 62 read from a scan by OCR; it may hold reading errors

For MICR data, the output data formatter operates after the MICR data has first passed through the MICR line parsing operation and the MICR line formatter. In this way, the MICR line data is left in the format presented by the MICR line formatter (the check verification/guarantee service provider’s format you select), or further customized. Please refer to the SCANTEAM 8300/8310 Programming Menu for detailed information and instructions for use of the MICR data formatter and editor.

MICR Data Processing 5-5

Page 63

5.4.1

Output Data Formatter Command Set

+ &,+',+ + + !* + + + + - + + . +& + !% + &) + + + ##/% +&&# - +& + !% + !% + MICR Characters for Bar Code Chart Roman Numeral

MICR Data

Roman Numeral

MICR Data

Alpha Char

Alpha Data

Digits

MICR Data

I II III IV V VI VII VIII IX X t1 t2 t3 t4 t5 t6 t7 t8 t9 t0

XI XII XIII XIV XV XVI XVII XVIII XIX XX o1 o2 o3 o4 o5 o6 o7 o8 o9 o0

A B C D E F G H I J a1 a2 a3 a4 a5 a6 a7 a8 a9 a0

0 (yes) 1 (no) 2 3 4 5 6 7 8 9 d0 d1 d2 d3 d4 d5 d6 d7 d8 d9

Special Functions

ESCAPE DEFAULT EXIT END PROGRAMMING

5–6

MICR Data tt0 tt1 tt2 tt3 where: t = transit symbol o=

On Us symbol a= amount symbol d= dash symbol

MICR Data Processing

Page 64 read from a scan by OCR; it may hold reading errors

5.5 MICR Character Signal Strength Testing

The SCANTEAM 8300/8310 is capable of detecting low character signal levels which may indicate fraudulent photocopied checks.

The signal level threshold for rejecting a check due to possible fraud is a programmable parameter for the SCANTEAM 8300/8310’s microcontroller.

The MICR decoding algorithm calculates and reports relative signal level information as an average for all characters.

Relative signal level is the ratio, stated as a percentage, that the signal level of the character being measured bears to the nominal signal level for that character with reference to the

WCC (wire card calibration) standard taken as 100 percent for the On-Us symbol. (Reference ANSI Standard X9.27-1988 Section 13.3.)

The host routine compares the average signal information for the characters to the programmed signal level parameter and rejects those checks with averages below the programmed minimum level, or above the programmed maximum level.

5.6 Error Condition Reporting

5.6.1 SCANTEAM 8300 LED Display Error Codes and Single Character Host Error Codes

The SCANTEAM 8300 can report certain error conditions through the use of error codes displayed on the LED display, as well as support error code reporting to the host device.

MICR Data Processing

5-7

Page 65

"!

"! &"

'&#'& $$"$ "!

Condition

Single Error Code LED Sent to Display Host

Good power-up initialization Good E13-B read Canadian check No account number Business check (unless Canadian) Travelers check No sequence number (unless Travelers check) Serial number less than 300 Old U.S. Check Good CMC-7 read Bad check - no MICR Low signal level High signal level Initial power-up calibration Power up initialization error Questionable MICR character Program mode Format error Check unreadable Exception Formatting Error Magnetic Interference

5–8

Double Error Code Sent to Beep Host Sequence

O O O O none none none none none 00 01 03

1 beep 1 beep 1 beep 1 beep

O O none none

08 12

1 beep 1 beep

O O O O n L H C F E P Y U J b none none none none N L H none F E none Y see list pg. 5–9 J none

11 15 04 00 09 10 none none none 06 none 11 none 11 none

1 beep 1 beep 1 beep 1 beep 3 beeps 3 beeps 3 beeps 3 beeps 3 beeps 3 beeps 2 beeps 3 beeps 3 beeps 3 beeps none

MICR Data Processing

Page 66

Unreadable (U) error codes: 0 1 2 3 4 5 6 7 8 9

Auxiliary On-Us field error (not bounded by On-Us symbols) Invalid EPC character Missing transit symbol Wrong number of digits in transit field Mod 10 check digit failure More than 24 characters in On-Us field No On-Us symbol in On-Us field No On-Us field Wrong number of digits in amount field Missing amount symbols

MICR Data Processing

5–9

Page 67

5–10

MICR Data Processing

Page 68 read from a scan by OCR; it may hold reading errors

MAINTENANCE 6

6.1 Paper Transport and MICR Read Head

The check reader drive roller and magnetic read head should be cleaned monthly or every 10,000 checks, whichever comes first. Clean the check reader drive roller and magnetic read head using a cleaning card saturated with an alcohol solvent. Welch Allyn offers a MICR head and transport cleaning card as a service item under the Welch Allyn product name “MICRCLEAN.”

Up to four check readers can be cleaned using a single cleaning card. When using the card on multiple check readers, orient the cleaning card so a clean area of the card enters the SCANTEAM 8300/8310 transport first.

6.2 Plastic Cabinet

The SCANTEAM 8300/8310 cabinet may be cleaned using most common liquid spray cleaners. The check reader may be damaged if the spray cleaner gets inside the cabinet, so do not spray the cleaning solution onto the check reader. Spray the cleaning solution onto a soft cloth, then clean the cabinet with the cloth. Do not use petroleum based solvents to clean the SCANTEAM 8300/8310 cabinet.

6.3 Magnetic Stripe Card Reader (MSR)

The MSR head should be cleaned every four weeks when there is a low to moderate transaction volume (such as in retail department stores and specialty stores). The MSR head should be cleaned every two weeks or weekly when there is a high transaction volume (such as in multi-lane stores and bank teller applications).

Maintenance 6-1

Page 69

- " !-

&

- " "

Note:

6–2

If you have a SCANTEAM 8300 with an integrated MSR, the MSR read head is located on the left hand side of the card slot (when viewed from the front).

Maintenance

Page 70

SERVICE AND REPAIR

7

Chapter 7 - Service and Repair

7.1 Obtaining Factory Service .0-4(#$1 1$04("$ %-0 (21 #$"-#$0 .0-#3"21 2'0-3&' (21 ,# -,& 1$04("$ "$,2$01 1 5$** 1 (21 + ,3% "230(,& ,# 1$04("$ % "(*(2($1 (, ,$ 2$*$1- -!2 (, 5 00 ,27 -0 ,-,:5 00 ,27 1$04("$ 7-3 1'-3*# 0$230, 2'$ 3,(2 .-12 &$ . "-.7 -% 2'$ # 2$# .30"' 1$ 0$"-0# +312 !$ 22 7.1.1

Service Under Warranty

"'$") 0$ #$0 " 00($1 7$ 0 5 00 ,27 %0-+ 2'$ # 2$ -% 00 ,27 1$04("$ + 7 !$ -!2 (,$# !7 "-,2 "2(,& 2'$ 2- 2'$ ,$62 . &$ %-0 ##0$11$1 ,# .'-,$ 5 00 ,27 12 2$+$,2 (1 *-" 2$# (, 2'$ !$&(,,(,& -% 2'(1 + ,3 7.1.2

Out of Warranty Service

"2-07 1$04("$ (1 *1- 4 (* !*$ %-0 -32 -% 5 00 ,27 .0-#3"21 -, 2(+$ ,# + 2$0( *1 -0 %(6$# .0("$ ! #$4("$ 1'-3*# !$ 0$230,$# .-12 &$ . (# %-0 0$. (0 -,*7 %2$0 -!2 (,(,& 2$0( * 2(-, %0-+ -32 -% 5 00 ,27 .0-#3"2 1$04("$ (1 0$/3(0$#- 7-3 5(** !$ #4(1$# -% 9,-2 2- .0("$ %-0 0$. (0 5'$, 2'$ 2$0( * 2(-, (1 %-**-5(,& (,%-0+ 2(-, (1 0$/3(0$# 2- .0-"$11 , %-0 2'$ .0-#3"2 ,# 1'-3*# !$ 4 (* !*$ %-0 2'$ 2(4$ ' ,#*(,& 7-30 (,%-0+ 2(-, (1 *-" 2$# -, 2'$ + ,3% * !$* 22 "'$# 2- 2'$ !-22-+ -% 2'$

* 2$ -% ,3% "230$ Service and Repair

7–1