Page 51
De-assert RTS, send to host terminal, then return to step a). Data messages received from the host must have a prefix (default “r” or “s”) to identify the message destination as either Aux 1 or Aux 2, respectively. If the prefix is not present, the data is ignored.
Notes: ¢ Therecanbeno more than a 15 second intercharacter delay
4-8 for characters in a data record. A timeout resets the data buffer, and all previous data for that record is lost.
e Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost.
¢ Parity and framing errors cause the SCANTEAM 8300 to error beep and to ignore the data record.
¢ Data sent to the SCANTEAM 8300 while the 8300 has RTS de-asserted will be lost.
4.4.2 Tranz™ 330 Protocol
This section describes how the main port of the SCANTEAM 8300 operates using the Tranz 330 protocol. (Please refer to the Terminal Selection and Main Port Configuration sections in the 8300 Programming Menu to program the SCANTEAM 8300 for the Tranz 330 protocol, and the baud rate and parity of the Tranz 330.)
The Tranz 330 protocol requires the SCANTEAM 8300 to have host port RS-232 hardware. Input/output to and from the Aux ports is not allowed. The end of a data record from the Tranz 330 is recognized by utilizing the 60ms delay timeout. The protocol is as follows:
a) The SCANTEAM 8300 sends data <STX>data<ETX>LRC where LRC is the XOR of all characters after the <STX>.
b) The expected response to data is <ACK> or <NAK>. If <ACK> or <NAK> is not received within 2.5 seconds, the data is assumed to be accepted. If a <NAK> is received, the data is re-sent. After the third <NAK>, the SCANTEAM 8300 gives up and enters its normal operating loop.
Software Operation
Page 52
Notes: ¢ Therecanbeno more than a 15 second intercharacter delay for characters in a data record. A timeout resets the data buffer, and all previous data for that record is lost.
e Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost.
¢ Parity and framing errors cause the SCANTEAM 8300 to ignore the data record.
4.4.3 Zon™ Jr. Protocol
The main port of the SCANTEAM 8300 operates in the following manner when using the Zon Jr. protocol. (Refer to the Terminal Selection and Main Port Configuration sections in the 8300 Programming Menu to program the SCANTEAM 8300 for the Zon Jr. protocol, and baud rate and parity of the Zon Jr.)
The Zon Jr. protocol requires the SCANTEAM 8300 to have host port RS-232 hardware. Input/output to and from the Aux ports is not allowed. The end of a data record from the Zon Jr. is recognized by utilizing the 60ms delay timeout. The protocol is as follows:
a) TheSCANTEAM 83800 sends <ENQ> to tell the Zon Jr. that it has data.
b) The SCANTEAM 8300 waits for <ETX><NUL> which tells it that data can be sent.
c) The SCANTEAM 8800 sends data <STX>data<ETX>LRC where LRC is the XOR of all characters after the <STX>. (If a MICR read error occurred, the data would be a single “2” character.)
d) The expected response to data is <ACK> or <NAK>. If <ACK> or <NAK> is not received within 2.5 seconds, the data is assumed to be accepted. If a <NAK> is received, the data is re-sent. After the third <NAK>, the SCANTEAM 83800 gives up and enters its normal operating loop.
Software Operation 4-9
Page 53
Notes: ¢ Therecanbeno more than a 15 second intercharacter delay for characters in a data record. A timeout resets the data buffer, and all previous data for that record is lost.
e Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost.
¢ Parity and framing errors cause the SCANTEAM 8300 to ignore the data record.
4.4.4 Host Command Protocol
This section describes the operation of the main port of the SCANTEAM 8300 when using Host Command Protocol, and when the user has programmed the SCANTEAM 8300 for a Terminal Selection of RS-232 (50) using the 8300 Programming Menu, and devices are connected to Aux ports 1 and 2.
The Host Command protocol requires that the SCANTEAM 8300 has the host port RS-232 hardware. It allows the SCANTEAM 8300 to operate with peripherals such as pin pads and signature capture units that do not support an RTS/CTS handshake. This protocol requires that the SCANTEAM 8300 host port and both Aux ports operate at the same baud rate (9600 or less). The SCANTEAM 8300 performs no parity checks but instead relies on the host port device and/or the peripheral devices to do so. The end of a data record from a port is recognized by programming the SCANTEAM 8300 port for either the 60ms Timeout or for the End of Record character search. To insure data integrity, the host device should implement an RTS/CTS handshake. The protocol is as follows:
a) Data messages received from the host must have a prefix (default “r” or “s”) to identify the message destination as either Aux 1 or Aux 2, respectively. All messages received from the Aux ports are sent to the host; no prefixes are necessary.
b) Once the message is sent to either Aux 1 or Aux 2, the SCANTEAM 8300 stays locked onto that port until a message is received from the host with a prefix indicating a different Aux port destination.
Software Operation
Page 54
c) Data messages from the host are received by sensing an external interrupt and then locking the SCANTEAM 8300 onto the host port to receive the message. During this time, any messages being sent from the Aux port(s) will be lost.
d) While the SCANTEAM 8300 is sending data messages to the host, the 8300 continues to look for data from the appropriate Aux port.
Notes: -¢ Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost.
¢ The SCANTEAM 8300 does not look for any receive framing errors.
4.5 Magnetic Stripe Card Reader Interface
The MSR port on the rear panel of the SCANTEAM 8300 is compatible with the SCANTEAM 6901 series of single, dual and triple track magnetic stripe readers as well as the optional integrated SCANTEAM 8300 magnetic stripe readers. It is designed to accept coded TTL level digital signals from the MSR. To format the MSR data for transmission to the SCANTEAM 8300’s host device, the SCANTEAM 8300 MSR port parameters must be programmed using MICR programming checks, a program parameter download from a PC or host device, or through the optional scanner port using the SCANTEAM 8300 Programming Menu. The SCANTEAM 8300 MSR port cannot be programmed using the magnetic stripe reader.
The SCANTEAM 8300 can decode mag stripe information contained on bank credit cards, travel and entertainment cards (e.g., American Express), which conform to ISO 7813 card standards for tracks 1, 2, and/or 3. The SCANTEAM 8300 may be configured to react and transmit to its host any combination of tracks 1, 2, or 3. Specific instructions for programming the MSR port are discussed in the SCANTEAM 8300 Programming Menu.
Software Operation 4-11
Page 55
AAMVA Driver’s License Magnetic Stripe Decoding
The data contained on tracks 1, 2, and 3 of an AAMVA (American Association of Motor Vehicle Administrators) or California driver’s license can be read and decoded by the SCANTEAM 8300 using the standard firmware shipped in every SCANTEAM 8300. Although the data format of track 3 ona driver’s license does not conform to ISO card standards, the SCANTEAM 8300 has the capability to decode this information.
Note: The AAMVA is developing a North American standard for driver's
4.6
4.7 license magnetic stripe data.
Bar Code Scanner Symbology
The optional bar code scanner interface on the SCANTEAM 8300 decodes the following bar codes:
UPC/EAN Code 128 Code 39
Contact your Welch Allyn Sales Coordinator if you need additional symbology decoding.
Displaying the Firmware Part Number and Revision Level
The revision level of the firmware operating in the SCANTEAM 8300 is embedded in the part number assigned to that firmware e.g., 34019XXX.
Whenever the reader is powered up or if the internal firmware executes a system reset, the current software revision level is flashed on the LED display. Four digits flash. The first three digits displayed are the current revision level of the software. The last digit indicates the state of the reader (refer to the Error Code chart on page NO TAG).
Software Operation
Page 56
4.7.1 PC Upload/Download Using Quick*Load
The SCANTEAM 8300 contains reprogrammable memory that contains the operating system for the 8300. This memory is a type of Read Only Memory (ROM) called flash memory. Flash memory can be electronically erased and reprogrammed like typical RAM, but does not lose its contents when power is lost.
When the SCANTEAM 8300 must be upgraded or modified, new operating system (firmware) or parameter data files must be placed into its flash memory. This is done using a special protocol, designed specifically for this purpose. The Welch Allyn software tool called Quick*Load is designed to implement the protocols used by the Welch Allyn flashable devices making it easy for users to download and upload firmware and run diagnostics on SCANTEAM products. Please refer to your Quick*Load manual for further information about using Quick*Load with your SCANTEAM 8300.
Software Operation 4-13
Page 57
4–14
Software Operation
Page 58
MICR DATA PROCESSING
5
Chapter 5 - MICR Data Processing The SCANTEAM 8300/8310 utilizes a sequential process to identify MICR characters, verify the integrity of data fields against ANSI/ISO specifications, and to manipulate the MICR data in a format compatible with the reader's host device requirements. The following chapter describes these functions. Note:
Please refer to Appendix A for Pre-Canned Format Error Code Reporting for the SCANTEAM 8310. All other information in this chapter is applicable to both the SCANTEAM 8300 and the SCANTEAM 8310.
5.1 MICR Character Recognition The SCANTEAM 8300/8310 uses a proprietary digital signal processing MICR character recognition technique which has its origins in the advanced bar code decoding technology used at Welch Allyn. This technique allows Welch Allyn to obtain a high character recognition rate and low substitution error rate on world" MICR documents.
5.2 MICR Line Data Parsing The SCANTEAM 8300/8310 contains a software algorithm which inspects MICR characters read from a check, then assigns groups of those characters (parses the data) to the following fields: 1
Auxiliary On-Us
2
External Processing Code
3
Routing (bank identifier)
4
On-Us (contains account number and check serial number)
5
Amount MICR Data Processing
5–1
Page 59
Once the MICR data is successfully parsed into these five information fields, the task of sub-parsing the On-Us field is performed. The SCANTEAM 8300/8310 On-Us field parsing algorithm is capable of parsing all the On-Us field formats which are in common use in North American retail banking today. Unfortunately, the content of the On-Us data field on a check (the account number and check serial number are in this field) is not covered by a banking or ANSI standard, and new MICR line data formats may appear on future checks which the SCANTEAM 8300/8310 cannot properly parse.
The SCANTEAM 8300/8310 contains a field programmable MICR Exception Table which allows the user to properly parse new MICR line formats which may be created by future check issuers.
Note: “Raw MICR’ refers to MICR data which is sent to the host system in the same order in which it is read by the check reader. The SCANTEAM 8300/8310 supports raw MICR output.
5.2.1 MICR Format Exception Table
The MICR Format Exception Table is a dedicated table in memory which may be loaded with instructions to correctly parse non-conventional MICR lines.
This exception table may be updated by any one of the following methods:
1. By passing a Welch Allyn custom printed MICR document through the check reader which contains the parsing instructions. (These custom documents may be obtained through the Welch Allyn Technical Support Group.)
2. By downloading the custom parsing instructions to the SCANTEAM 8300 through its Aux port from a PC or other RS-232 device.
3. By downloading the custom parsing instructions to the SCANTEAM 8300/8310 through its host communication port (host down line load).
MICR Data Processing
Page 60
4.
By cloning the memory contents from another SCANTEAM 8300/8310 which has already been updated to include the new exception table instructions.
5.
By scanning a bar code from a SCANTEAM 8300/8310 Programming Menu (if a scanner port is configured on the SCANTEAM 8300, or if a decoded output bar code scanner has been attached to the SCANTEAM 8310's host interface port).
5.3 MICR Data Formatter Every SCANTEAM 8300/8310 contains a MICR data formatter which is used by the SCANTEAM 8300/8310 to arrange the MICR data fields (bank transit number, account number, check serial number, and amount) from the MICR line on a check before sending that information to a host system. The SCANTEAM 8300/8310's MICR data formatter allows the SCANTEAM 8300/8310 user to select from a list of common formats which are used by the major check verification and guarantee services. These formats may be selected during the initial set up of the SCANTEAM 8300/8310 user configuration parameters. The parameters are input by feeding MICR encoded programming checks (available from Welch Allyn) into the check reader, scanning bar codes from the 8300/8310 Programming Menu with an RS-232 device (e.g., a wand), downloading parameters from the host or an RS-232 device, or by cloning existing parameters from a SCANTEAM 8300/8310 to a SCANTEAM 8300/8310.
MICR Data Processing
5–3