Page 21
Schematic diagrams of the input and output circuits for the TTL logic (Pseudo RS–232) are shown in Figure 2.1.
VCC VCC R8 1K
R6 100K
Q3 2N4403 R7 10K
Q2 2N4401
R9 2.7K
D1 1N4148
R10 15K
Input Circuit
Q4 2N4401
Output Circuit
Figure 2.3 SCANTEAM 6180 Input and Output Circuits Schematic diagrams of the input and output circuits for the true RS–232 levels are shown in Figure 2.2. The operation of the DS1275 chip is unique in that it “steals” current from the receive input when transmitting a negative swing. Since most serial communications ports remain in a negative state statically, using the receive signal for negative power greatly reduces current consumption.
TXD
TX DS1275
RXD
RX
Figure 2.4 SCANTEAM 6180 Input and Output Circuit for the True RS–232 Scanner Operational Description
2–7
Page 22
2.6 External Power Welch Allyn offers two options for supplying external power when it cannot be supplied by the host and the 9 pin D connector with pigtail power plug is ordered. A +5VDC transformer type power supply both with 5 Pin DIN male connectors that directly interface with the pigtail power plug may be ordered. The +5VDC power supply can be ordered to operate at 110VAC or 220VAC.
2–8
Operational Description
Page 23
SET–UP AND INSTALLATION
3.1 Chapter Description This chapter describes: •
Unpacking the SCANTEAM 6180
•
Connecting the SCANTEAM 6180
•
Confirming scanner operation
•
Checking bar code labels
3.2 Preparation The SCANTEAM 6180 is shipped ready for use. Upon receipt, open the carton(s) and check the contents. Check the part numbers and confirm that each item on the packing list has been supplied. Thoroughly inspect each component for possible shipping damage. Any damage should be reported immediately to the carrier who delivered the shipment. Damage claims due to handling during shipment should be placed directly with the carrier. When all components have been identified and checked, prepare the wand for service using the following procedure.
3.3 Set–up And Installation 1)
Position the host unit power switch to the “OFF” position.
2)
Attach wand to host device. If external power will be supplied by the host device, insert the wand 9–pin female D connector into the 9–pin RS–232 asynchronous port on the host system. Secure it in place by tightening the two retaining screws. If an external power source is used, the 5–pin DIN connector (the pigtail) must be connected to the power source plug.
3) 3–1
Restore power to the host unit by turning the power switch to the “ON” position. Set–Up and Installation
3
Page 24
3.4 Scanner Checks 1) Confirm Scanner Operation Tthe tip of the scanner should glow red indicating that the wand is operational. 2) Check Bar Code Labels Before using any bar code scanner, make sure the label is of good quality and that the window area of your scanner is clean. This is very important because any dirt or specks in the bar code symbol or on the scanner optics may prevent it from reading accurately. Even a label that is smudged during printing or gets wrinkled when it is applied to an item can cause a reading problem. This completes installation of the wand to the host system. The wand reader/decoder must now be configured to the particular decoding application. Welch Allyn offers two programming methods. The standard programming technique involves using the wand to scan bar code symbols from a Programming Menu. An alternative programming method makes use of an optional Configuration Disk. The disk contains software (WANDMENU), which allows the user to select and download decoder parameters from the host using a PC menu program. A description of all programmable parameters and the instructions for making decoder selections using these two programming methods are contained in Chapter 4.
Set–Up and Installation
3–2
Page 25
PROGRAMMING THE SCANNER
4
4.1 Introduction Before the SCANTEAM 6180 can be placed in operation it must be configured to the particular application. Either of two programming methods can be used. The standard method supplied with the SCANTEAM 6180 unit makes use of the wand to scan bar code symbols from the Programming Menu. As programming sequences are decoded by the wand, the desired operating parameters and data format instructions which they represent are stored in non–volatile memory on the decoder printed circuit board. An optional programming technique requires both the use of a special Configuration Disk available from Welch Allyn and a PC host to program the decoder. The disk contains software routines that permit the user to select and download decoder parameters from the host. The configuration program (WANDMENU) is driven by a PC. Operating parameters are selected using a menu displayed on the PC screen. WANDMENU software allows the user to simultaneously display the current status of all decoder parameters and to save a desired decoder configuration for use at a later time.
4.2 The Programming Menu The complete SCANTEAM 6180 Programming Menu consists of three (3) pages: two Menu Pages and the Bar Code Chart. The two menu pages are labeled: INPUT/OUTPUT PARAMETERS & FORMAT and SYMBOLOGY SELECTIONS. These pages list the decoder parameters controlled from that menu page and indicate the scanning sequence required to make specific configuration selections. The symbols used to control the configuration process are printed on the Bar Code Chart. 4.2.1 Programming Menu Pages The general operating parameters associated with each of the menu pages are listed below.
Programming the Scanner
4–1
Page 26
INPUT/OUTPUT PARAMETERS & FORMAT
Contains Baud rate, parity, message preamble/postamble definition, intercharacter delay, “Good Read” indication and append buffer SYMBOLOGY SELECTIONS
Contains both retail and industrial code selections and their variations. In addition, code variables such as maximum and minimum code length, check character, start/stop character and addenda/append options. The Menu Page used to configure the decoder INPUT/OUTPUT PARAMETERS & FORMAT is shown in Figure 4.1.
INPUT/OUTPUT
SCANTEAM SRD–6180/SID–6280 Programming Menu USE THIS PAGE To select baud rate and parity. To add preambles, postambles, and/or code identification character to the bar code. To set intercharacter delay to a specific value. To control scanning indicator (blink). scan To enable the Append Buffer when Code 3 of 9 with append option is selected. To enable CTS handshake.
PARAMETERS & FORMAT
ENTER selections scan
BAUD RATE scan
DEFAULT scan variables scan
150 300 600 1200 2400 4800 9600 19200
A
Mark Space Even Odd STX Code ID Other ASCII ETX CR LF Other ASCII
A B C* D A B* C A B* C* D A* B
PARITY
PREAMBLE (up to 5 chars)
POSTAMBLE (up to 5 chars)
INTERCHAR. DELAY (x5msecs)
No Yes
APPEND BUFFER
Enable
RTS/CTS PROTOCOL
B C D E F G* H
NOTES: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples.
EXIT
Figure 4.1 Example of Programming Menu Page 4–2
Programming the Scanner scan
00–7F
00–7F *00–99 *Yes/No Yes/No*
Page 27
Both Menu Pages follow a similar layout and list the selection of programmable parameters along with the parameter variables. SELECTIONS/VARIABLES
These columns list the program–ming parameter Selections and identify the Variables which can be chosen to modify the default settings. SCAN
These columns indicate which bar code symbol(s) on the Bar Code Chart (i.e., Roman Numeral, Letter or Number) that the user must scan in order to configure a particular decoder parameter to a desired value. ENTER
At the top of each Menu Page is a symbol labeled ENTER which is unique to that Menu Page. The ENTER command “activates” that Menu Page, and must be scanned before configuring parameters shown on that page. 4.2.2 The Bar Code Chart The SCANTEAM 6180 Bar Code Chart shown in Figure 4.2 is also part of the Programming Menu. It contains the printed bar code symbols which are scanned to program the desired selections.
Programming the Scanner
4–3
Page 28
SCANTEAM SRD–6180/SID–6280 Programming Menu
BAR CODE CHART
USE THIS PAGE In combination with the adjoining menu pages to program the 6180. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.
ROMAN NUMERALS
I
LETTERS
DIGITS
A XI
OTHERS
ESCAPE 0 (YES)
II
B XII
III
DEFAULT 1 (NO)
C XIII
IV
W.A. 2
D XIV
V
3 E
XV VI
4 F
XVI
5
Figure 4.2 Bar Code Chart Note that the chart contains symbol groupings that include ROMAN NUMERALS, LETTERS and NUMBERS. The sequence in which these symbols are scanned generates the programming instructions which enable or disable specific decoder functions. The right hand column of the Chart contains three (3) bar code symbols labeled DEFAULT, ESCAPE and WA. When these symbols are scanned specific instructions are instantaneously sent to the wand. 4–4
Programming the Scanner
Page 29
The function of these commands is explained below. DEFAULT
Scanning this symbol installs default values (indicated by *’s) at the active programming level. For example, if the DEFAULT symbol is scanned immediately following Page ENTER, it defaults the entire menu page. If it is scanned following a major category selection like Codabar, it will default that whole category. If DEFAULT is scanned following a subcategory selection such as Code 128/Minimum Length, it will default just that subcategory. Finally, if it is scanned immediately after scanning the WA symbol, all of the wand Selections and Variables (on both menu pages) will automatically default to those values indicated by the asterisk (*). WA
As explained above, the WA symbol generates a global command. It is intended to be used in conjunction with the DEFAULT symbol to reset all wand decoder parameters to their default values. The sequence scan WA followed by scan DEFAULT will cause all Selections and Variables on both menu pages to reset to their default values. EXIT
Scanning the EXIT symbol produces a command which can be used to terminate programming on either menu page. The EXIT symbol must be scanned before moving to or attempting to program on a different menu page. When it is scanned, all configuration instructions for parameters appearing on that page will be stored in memory. ESCAPE
Scanning the ESCAPE symbol generates a command that will terminate a programming sequence before it is completed and without saving the configuration information. It can be used when a Selection and/or Variable has been scanned in error. The programming sequence must then be restarted.
Programming the Scanner
4–5
Page 30
4.3 INPUT/OUTPUT PARAMETERS & FORMAT Menu Page This menu page is used to configure basic terminal operation. The scanning sequences described on this page permit the user to select baud rate and parity, specify message preamble(s) and/or postamble(s), set the value for intercharacter delay and enable the Append Buffer. Baud Rate
Baud rate is a means of specifying data transmission speed. This programming selection permits the user to configure the wand for any of eight (8) values ranging from 150 to 19200 baud. Parity
Parity provides a means of checking character bit patterns for validity. The wand can be configured to operate under Mark, Space, Even or Odd parity options. Preamble
Preambles are assigned using the programming menu. When the Preamble selection is enabled, any combination of up to five identifiers are transmitted as a header immediately preceding scanned bar code data. Preamble characters may include Start Transmission (STX), Code ID and the ASCII characters (00–7F). These characters will be transmitted in the order in which the selections are programmed. Both preamble and postamble menuing always start with a clean slate. Therefore, to clear all preambles, it is necessary only to complete the programming sequence SCAN ENTER, SCAN III, SCAN EXIT. If the Code ID is selected as a preamble, the wand will transmit a single lower case ASCII character to identify which symbology was decoded. For example, Code 3 of 9 is identified by a lower case “b,” while Code 128 is identified by a lower case “j.”
4–6
Programming the Scanner