SCANTEAM 6180 Wand Serial Interface/RS-232 Decoded Out Wand Technical Manual, pages 11 to 20

Pages 11 to 20 of 68

The original document is the PDF (234 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST6180

Page 11

Related Publications Reading Between the Lines: An Introduction to Bar Code Technology Craig K. Harmon and Russ Adams 1989 Helmers Publishing Inc. 174 Concord Street Peterborough, NH 03458 (603) 924–9631 The Bar Code Book: Reading, Printing, and Specification of Bar Code Symbols Roger C. Palmer 1989 Helmers Publishing Inc. 174 Concord Street Peterborough, NH 03458 (603) 924–9631 Handbook of Bar Coding Systems Harry E. Burke 1984 NCR Corporation Van Nostrand Reinhold Company, Inc. 115 Fifth Avenue New York, New York 10003 Automatic ID Resource Catalog AIM USA Publications 634 Alpha Drive Pittsburgh, PA 15238–2802 Fax: 412–963–8753 Phone: 412–963–8588 AIM “Guidelines on Symbology Identifiers,” “Uniform Symbology Specifications” (USS), and other AIM resources from the address above. Table of Contents v

Page 12

vi

Table of Contents

Page 13

INTRODUCTION TO THE SCANTEAM 6180 SCANNER

1

1.1 Introduction The SCANTEAM 6180 Bar Code Wand Reader/Decoder is a convenient and cost effective way of adding bar code reading and decoding capability to bar code terminals and personal computers. The SCANTEAM 6180 has visible red illumination and a stainless steel housing. The SCANTEAM 6180 reads and decodes nine (9) popular bar code symbologies and outputs the bar code data to any host having an RS–232 port using asynchronous serial ASCII format.

1.2 Hardware Description The standard SCANTEAM 6180 unit consists of the wand body, a 6’ (1.8m) coil (extended) or straight interface cord, and the 9–pin D metallized plastic shell terminating connector available with or without an external power plug.

Figure 1.1 SCANTEAM 6180 with External Power Plug

Introduction to the SCANTEAM 6180

1–1

Page 14

The decoder output is designed so the wand will interface with any TTL logic level or RS–232 logic level asynchronous port. All 6180 wands are referred to as contact scanners since the tip of the scanner must be in or near contact with the bar code label in order to read. The SCANTEAM 6180 may be ordered with high, medium or low resolution scanning optics to meet special requirements imposed by the label substrate and printing method or environmental factors that affect bar code label quality.

1.3 Software Description The standard SCANTEAM 6180 is configured for specific user applications by scanning bar code symbols from the printed programming menu which is supplied with the unit. The wand may also be programmed through a host download method which utilizes a PC based menu program. Software and instructions for implementing this optional programming technique are described in Section 4.6 of this manual. The 6180 may be programmed to autodiscriminate among the following bar code symbologies and their variations: Codabar, Code 3 of 9, UPC, EAN/JAN, Interleaved 2 of 5, Code 2 of 5, MSI, Code 93, Code 128 and Code 11§. In addition to the bar code symbology selections, certain input/output parameters, message format and communications protocol are programmable using the wand with the programming menu. All programmable parameters are stored in a non–volatile memory resident in the wand where they are permanently retained in the event of power interruption to the decoder. §

1–2

This feature is not supported in all wand models/software revisions.

Introduction to the SCANTEAM 6180

Page 15

OPERATIONAL DESCRIPTION

2

2.1 Chapter Objectives This chapter describes: • • •

Overview of how the SCANTEAM 6180 works, including scanning aperture, depth of field and scanning velocity. Reading and decoding a bar code symbol. Description of print contrast, high and low density bar code symbols. Discussion of RS–232 interface and external power options.

2.2 Main Elements of the 6180 Bar Code System The major operational elements of the SCANTEAM 6180 include the scanner optics, the digitizing electronics and the decoding circuitry. The key components of the scanner optical system are the illumination source (LED) and the illumination sensor (photodiode). Both the LED and photodiode are positioned directly behind a specially designed lens in the scanner body. Cable connections are made directly to the board and exit the scanner body through a flexible strain relief at the end of the wand handle. The integral cable shield affords EMI and associated drain protection to output signals.

Operational Description

2–1

Page 16

2.3 Operating Theory The reading ability of the wand scanner is based on the detection of reflected illumination from the bars and spaces which form a bar code symbol. During a typical scanning operation, the tip of the scanner is moved across the bar code symbol. Illumination from the LED is focused on the bar code symbol. This is absorbed by the dark colored bars and reflected by the lighter background. The reflected portion re–enters the scanner through the lens where it is detected by the read sensor photodiode. The photodiode converts this into a series of analog pulses which are proportional in width to the bars and spaces in the symbol. These pulses are then digitized and sent to the microprocessor where they are decoded into the characters represented by the bar code symbol.

2.4 Factors Affecting Scanning Performance The following factors influence reading performance and should be considered when selecting a contact scanner for a particular bar code application. 2.4.1 Scanner Illumination Source Wand type scanners are equipped with a visible red (660nm) source. Red illumination is compatible with most printing inks including most thermal papers. Because it provides a visual indication to the operator that the scanner is functioning, red illumination is considered to be more user friendly. Visual feedback to the operator is an important consideration when making a scanner selection. 2.4.2 Scanning Aperture Scanning performance is affected by the size of the scanning aperture and it is a significant factor to be considered when selecting a scanner. The scanning aperture defines the effective size of the area of the bar code symbol viewed by the scanner optics. It affects the relative ability of the scanning device to “see” or resolve bars and ignore printing defects.

2–2

Operational Description

Page 17

Large aperture systems typically cannot resolve high density bar code or the small printing features (voids within bars or dark specs within the light areas) that small aperture systems would. Thus, they are more compatible with low density bar code and more tolerant of printing defects characteristic of poorly printed labels. Small aperture systems (high resolution) are better able to resolve which makes them compatible with high density good quality symbol reading requirements. The SCANTEAM 6180 is available with circular apertures ranging from 6 to 10 mil. Most scanning applications can be satisfied with a 6 mil (high resolution) or a 10 mil (low resolution) aperture. When selecting an aperture, it is recommended that the aperture dimension be no less than 0.7 times the “X” (width of the narrowest bar code coding element) dimension to be read. An aperture size that is slightly smaller than the narrowest bar code element, 0.9 times “X,” provides optimum resolution of the bars and results in the generation of a digital signal which accurately represents the bar code. An 8 mil (0.2mm) aperture is often a good compromise when labels produced by different printing and label generation methods must be read with one scanner. In no case should the viewing aperture exceed 1.2 the “X” dimension.

-

- -

- -

- -

-- - --

Figure 2.1 Aperture and Depth of Field 2.4.3 Depth of Field Depth of field is the maximum perpendicular distance from the scanner tip to the bar code symbol surface at which the scanner is capable of operating effectively. In general, most of the SCANTEAM 6180 scanners have a depth of field of 0.065 inches (1.65mm) with a symbol appropriate for the scanner.

Operational Description

2–3

Page 18

In normal use, the wand is seldom held perpendicular to the surface of the bar code symbol. Rather, an operator tends to tilt the scanner. Useable scan angle is a function of tip geometry and depth of field. If the depth of field is too small, the scanner may fail to operate at extreme tilt angles (>35°).

- - - -

-- - --

Figure 2.2 Range of Angle 2.4.4 Scanning Velocity The wand will operate at scan velocities from 2 to 50 inches/second (5 to 127cm per second) when the minimum bar/space size exceeds 7 mils (0.18mm). 2.4.5 High Density vs Low Density Bar Code Symbols Bar code density is a measure of the number of characters in a linear measure of bar code. The standard of measure is normally given in terms of the “X” dimension, the width of the narrowest bar code element. As bar code density increases, the width of the narrowest bar code element decreases. The scanning aperture should always be smaller then the narrowest element to assure optimum resolution and the generation of a digital signal which accurately represents the bar code. 2.4.6 Print Contrast Print contrast is a measure of the relative difference in brightness between the bars and spaces of a symbol and is specified as the Minimum Reflectivity Difference (MRD). The MRD is the difference between the lowest minimum space reflectance value and the highest maximum bar reflectance value as measured across the entire symbol. MRD = Max (Rb max) – Min (Rs min) where:

Rs min = Minimum Space Reflectance Rb max = Maximum Bar Reflectance

The scanner will operate with a MRD as low as 37.5% with the proper aperture and appropriate symbol. 2–4

Operational Description

Page 19

A complete description of bar code specifications for factors which affect overall bar code quality are provided in Appendix B.9.

2.5 Interface Description The SCANTEAM 6180 transmits bar code data in a serial ASCII format (RS–232) and is designed to interface to any standard RS–232 asynchronous port. The wand cable is offered with four (4) standard connector options. For Option 1, the interface cable will be terminated in a 9 pin D female connector. Power will be available on pin 9. If Option 2 is specified, the cable will be terminated in a 9 pin D female connector with a pigtailed 5 pin DIN female connector for power. For Option 3§, RTS/CTS lines are used and the interface cable will be terminated in a 9 pin D female connector. Power will be available on pin 9. If Option 4§ is specified, RTS/CTS lines are used and the cable will be terminated in a 9 pin D female connector with a pigtailed 5 pin DIN female connector for power. Pin assignments for each option are shown below. A complete wire color code/function description of the interface is provided in Appendix B.3. Note:

§

Data bits and stop bits are not configurable on the 6180. The 6180 is always set up for data transmission at 7 data bits and 1 stop bit.

This feature is not supported in all wand models/software revisions.

Option 1 – 9 Pin D: Pin 2 Transmit (Data from the Wand) Pin 3 Receive (Data sent to Wand) Pin 5 Ground Pin 9 +5VDC + 5% Option 2 – 9 Pin D w/Pigtail Power Plug: 9 Pin D

Pin 2 Pin 3 Pin 5

Transmit (Data from the Wand) Receive (Data sent to Wand) Ground

Pigtail Power Plug

Pin 1 Pin 3

Ground +5VDC+ 5% Operational Description

2–5

Page 20

Option 3§ – 9 Pin D, RTS/CTS: 9 Pin D

Pin 2 Pin 3 Pin 5 Pin 6 Pin 7 Pin 9

Tx: Transmit (Data from the Wand) Rx: Receive (Data sent to Wand) Ground CTS RTS +5VDC + 5%

Option 4§ – 9 Pin D, RTS/CTS: 9 Pin D

Pin 2 Pin 3 Pin 5 Pin 6 Pin 7

Tx: Transmit (Data from the Wand) Rx: Receive (Data sent to Wand) Ground CTS RTS

Pigtail Power Plug

Pin 1 Pin 3 §

Ground +5VDC+ 5%

This feature is not supported in all wand models/software revisions.

Connector pin 2 is reserved for data transmitted from the wand to the host. It obeys RS–232 data formats, but uses 0 to +5V logic swings. It is in effect, TTL RS–232C logic. It is also available in true RS–232 levels. Connector pin 3 is reserved for data sent to the wand. The wand can receive data either at RS–232 levels (–3V to – 15V or +3V to +15V) or at logic levels (0 to +5V).

2–6

Operational Description