Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of HHP ScanTeam 6180 Bar Code Wand Reader/Decoder Spec Sheet

Spec sheet · HHP

HHP ScanTeam 6180 Bar Code Wand Reader/Decoder Spec Sheet

Spec sheet2 pagesPDF 118 KB

Both pages are below, each with its text.

Download the PDF118 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

The two-page HHP spec sheet (6180/SS Rev B, 10/02) for the SCANTEAM 6180 Instant Interface Series bar code wand, which has its decoder built into the wand housing. It lists the features, optical performance, programmable symbologies, size, power, connector and environmental limits.

Device
Bar code wand with the decoder inside the wand housing; sends decoded data as serial ASCII p. 1
Interface
TTL RS-232 output; input accepts TTL or true (+12VDC) RS-232 p. 2
Power
4.5 to 5.5VDC (up to 100mV peak to peak noise); 19mA scanning, 3-4 mA in low power mode p. 2
Connector
9 pin D shell standard, other terminations available; lines +5VDC, ground, receive and transmit data p. 2
Symbologies
Autodiscriminates Code 39, Interleaved 2 of 5, Code 2 of 5, UPC-E/A, MSI, EAN/JAN, Code 128, Code 93, Code 11, Codabar p. 2
Optics
660nm visible red LED; 6 mil or 8 mil aperture p. 2
Scanning
2-50 in./sec. scan speed; 0.065 in depth of field; 0 to 35 degree tilt typical; 37% minimum reflectance difference p. 2
Size and weight
7.5 in. long with strain relief, 0.50 in. diameter; 3.6 oz. with a 6 foot coiled cord p. 2
Housing
Metal, with a field replaceable sapphire tip and a beeper inside p. 2
Temperature
Operating -4 to 122 F (-20 to 50 C); storage -40 to 158 F (-40 to 70 C); 95% humidity max p. 2
Drop rating
Works after fifty 3 foot drops onto concrete p. 2
Wand emulation
Can output Code 39 as a digital wand signal, so a Code 39 system reads 10 more symbologies p. 1
Power options
External power supply or battery pack for serial ports without power p. 1
Approvals
The spec sheet states FCC Class B and CE p. 2

What this sheet walks you through

  • Programming the wand from a host or a bar code menu p. 1
  • Settings kept in non-volatile memory: data format, protocol, I/O and symbologies p. 2
  • Powering the wand from a port without power p. 1

Good to know

  • Specifications and features may change without notice. p. 2

Questions this sheet answers

What voltage does the SCANTEAM 6180 wand need?

4.5 to 5.5VDC, drawing about 19mA while scanning and 3-4 mA in low power mode. p. 2

What connector does the SCANTEAM 6180 use?

A 9 pin D shell as standard, carrying +5VDC, ground, receive and transmit data; other terminations were available. p. 2

Which bar codes can the SCANTEAM 6180 read?

Ten: Code 39, Interleaved 2 of 5, Code 2 of 5, UPC-E/A, MSI, EAN/JAN, Code 128, Code 93, Code 11 and Codabar. p. 2

Does the SCANTEAM 6180 need a separate decoder?

No. The decoder is built into the standard wand housing. p. 1

The file

Size and text

Pages2
PDF118 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of HHP ScanTeam 6180 Bar Code Wand Reader/Decoder Spec Sheet

The text of page 1, from the PDF itself

SCANTEAM® 6180 Instant Interface Series Bar Code Wand Reader/Decoder

Features Outputs Decoded Bar Code Data in Serial ASCII Format Serial Communication; TTL (0 and +5VDC)

The SCANTEAM® 6180 is HHP's bar code wand reader/decoder that simplifies scanning and decoding

Decoder Contained in the Standard Wand Housing - No external decoder required

by combining both functions into its standard wand housing.

Programmable From Host or Bar Code Menu - Easy to program

HHP's SCANTEAM® 6180 is an economical, compact solution for any bar code data collection application that provides an RS-232 port.

AutoDiscriminates 10 Bar Code Symbologies - Suitable for a variety of bar code reading applications Wand Emulation Converts to Code 3 of 9 Digital Output Upgrades a system that decodes Code 39 to decode 10 additional symbologies External Power Supply or Battery Pack Available - Option for serial port without external power options offered for customer convenience

Upgrade your image.

Page 2 of HHP ScanTeam 6180 Bar Code Wand Reader/Decoder Spec Sheet

The text of page 2, from the PDF itself

SCANTEAM® 6180 Specifications Performance Input/Output:

Output Format: TTL RS-232 Input Format: Accepts TTL or True (+12VDC) RS-232 interchangeable

Good Read Indicator: Aperture
Audible 6 mil, 8 mil
Light Source
660nm Visible red LED
Tilt Angle
0o-35o typical
Depth of Field
0.065 in (1.6mm)

Minimum Reflectance Difference (MRD):

37%

Scan Speed
2-50 in./sec. (5-127cm/sec.)

Programmable Features Programmable features that are stored in non-volatile memory include data format, communications protocol, input/output parameters and autodiscrimination among the following symbologies: Code 39 Interleaved 2 of 5 Code 2 of 5 UPC-E/A MSI

EAN/JAN Code 128 Code 93 Code 11 Codabar

Mechanical/Electrical Dimensions Weight: Length:

3.6 oz. (102g) with 6 foot (1.8m) coiled cord 7.5 in. (19.1cm) includes strain relief

Diameter
0.50 in. (1.3cm)
Scanner Housing
Metal
Scanner Tip
Field replaceable sapphire tip

Power Requirements Operating Voltage:

4.5 to 5.5VDC: up to 100mV peak to peak noise

Operating Current
Active (scanning) = 19mA typical Low power mode (not scanning) = 3-4 mA typical
Electrical Connections
+5VDC Ground Receive Data Transmit Data
Connector
9 pin D shell standard; other terminations available
Beeper
Located in scanner housing
Cord
Standard 6 foot coil cord (1.8m).

Environmental Temperature Operating: Storage:

-4oF to 122oF (-20oC to 50oC) -40oF to 158oF (-40oC to 70oC)

Humidity
95% maximum non-condensing
Shock
Functions normally after fifty 3 foot drops onto a concrete surface
Agency Approval
FCC Class B, CE

Complies with EMC 89/336/EEC LVD 73/23/EEC

W orldw ide O ffices O ffices Serving N orth Am erica Skaneateles Falls, NY Tel: +1 315 685 8945 or, in North Am erica: +1 800 782 4263 sales@ hhp.com Charlotte, NC Tel: +1 704 998 3998 or, in North Am erica: +1 800 782 4263 sales@ hhp.com

O ffices Serving Europe, M iddle East, and Africa Europe Tel: +31 (0) 40 29 01 600 euro_sales@ hhp.com United Kingdom Tel: +44 (0) 1 925 240055 euro_sales@ hhp.com Ireland Tel: +353 (0) 502 44007 euro_sales@ hhp.com

France Tel: +33 (0) 1 461 04111 euro_sales@ hhp.com G erm any Tel: +49 (0) 7 477 151377 euro_sales@ hhp.com Spain Tel: +34 93 228 76 68 euro_sales@ hhp.com

O ffices Serving Asia and the Pacific R im

Hong Kong Tel: +852 2511 3050/2511 3132 asia_sales@ hhp.com Japan Tel: +813 52127392 asia_sales@ hhp.com

W eb Site Address www.hhp.com Hand Held Products, Inc. d/b/a HHP (“HHP”)  1999-2002. All rights reserved. Printed in the U.S.A. Due to HHP’s continuing product im provem ent program s, specifications and features herein are subject to change without notice.

6180/SS Rev B

10/02

O ffices Serving Latin Am erica Naples, Florida Tel: +1 239 263 7600 la-sales@ hhp.com São Paulo Tel: +55 11 5016 3454 la-sales@ hhp.com Rio De Janiero Tel: +55 21 2494 7060 la-sales@ hhp.com

More documents · 2