Page 31
Symbology Chart Code ID [
Hex Value
Code 11 h
68
Code 93 i
69
63
Code 128 j
6A d e
64 65
Matrix 2 of 5 Plessey m n
6D 6E
Code 2 of 5 f
66
All Symbologies
MSI g
67
(Prefix/Suffix Programming only.)
Code ID [
Hex Value
Codabar a
61
Code 39 b
62
UPC c
EAN Interleaved 2 of 5
Symbology
Symbology
99
Hex to ASCII Conversion Chart ASCII
Hex
ASCII
Hex
ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
SP 20 ! 21 ” 22 # 23 $ 24 % 25 & 26 ’ 27 ( 28 ) 29 * 2A + 2B , 2C – 2D . 2E / 2F
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ 40 A 41 B 42 C 43 D 44 E 45 F 46 G 47 H 48 I 49 J 4A K 4B L 4C M 4D N 4E O 4F
P 50 Q 51 R 52 S 53 T 54 U 55 V 56 W 57 X 58 Y 59 Z 5A [ 5B \ 5C ] 5D ^ 5E _ 5F
‘ 60 a 61 b 62 c 63 d 64 e 65 f 66 g 67 h 68 i 69 j 6A k 6B l 6C m 6D n 6E o 6F
Hex p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F
Note: Prefix / Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Note: Adding a Prefix or a Suffix appends that Prefix / Suffix to any existing entries for the symbology(s) you’ve chosen. For example, if you’ve already programmed and saved a CR / LF (carriage return / line feed) and add a “#” Prefix, the ”#” will be sent after the CR / LF. If you add a Prefix / Suffix but want existing entries cleared, you’ll need to use the Clear Specific Prefix / Suffix programming selection first. Then use the Add Prefix / Suffix programming selection to program your new Prefix / Suffix.
SCANTEAM 5700 User’s Guide
2–7
Page 32
✱ Default All Output Settings ✱
Beeper Volume Selection
Off
Low
Medium
✱ High
Output Delays Selection This selection provides control of the time delays between data output by the scanner to the host terminal. The actual delay is 5 milliseconds multiplied by the programmed value (00 – 99). Default = 00. Intercharacter Delay is the time delay between data characters output by the scanner to the host terminal. Interfunction Delay is the time delay between function (key) codes output by the scanner to the host terminal. Intermessage Delay is the time delay between data messages or records output by the scanner to the host terminal. Example: You need a 45 millisecond delay. Scan the Intercharacter Delay bar code. Then scan “0” and “9” on the Programming Chart (09 x 5ms = 45 ms).
Intercharacter Delay (x5mS) ]
Interfunction Delay (x5mS) ]
Intermessage Delay (x5mS) ]
] A two-digit number is required after scanning this programming bar code. Please scan your selection on the Programming Chart (inside back cover).
2–8
SCANTEAM 5700 User’s Guide
Page 33
Reread Delay Selection This selection allows you to set a time period that must pass before the scanner can read the same bar code again. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads at POS (point of sale) terminals. Use shorter delays in applications where repetitive bar code scanning is required.
✱ Low (175 milliseconds)
Medium (450 milliseconds)
High (1.0 second)
Extra High (2.0 seconds)
Good Read Delay Selection This selection allows you to set a time period that must pass before the scanner can read another bar code. Some terminals require a slower read rate. By setting a good read delay, you can ensure a good read.
✱ None
Low (500 milliseconds)
Medium (1.0 second)
High (1.5 second)
Laser Voting Selection When Laser Voting is enabled, the scanner requires three (3) identical, consecutive scans before the bar code data will be accepted and transmitted to the terminal. When this selection is disabled, the bar code data will be transmitted following one (1) valid scan.
✱ Disable
Enable
SCANTEAM 5700 User’s Guide
2–9
Page 34
Buffered Scans Selection When enabled, this selection allows the scanner to accept a second scan while the current scan is transmitted to the host terminal (buffering of scanned data). When disabled, the scanner cannot accept additional scans until the current scan is transmitted to the host. Default = Enable.
✱ Enable
Disable
Code I.D. Transmit Selection This allows you to enable or disable transmission of a Code I.D. before the decoded bar code symbology. (See the Symbology Chart on page 2–7 for the single character code that identifies each symbology.)
✱ Disable
Enable
AIM I.D. Transmit Selection This selection allows you to enable or disable transmission of an AIM I.D. before the decoded bar code symbology. (See AIM Guidelines on Symbology Identifiers for more information on the AIM symbology ID characters.) Default = Disable.
✱ Disable
Enable
Function Code Transmit Selection When this selection is enabled, and function codes are contained within the scanned data, the scanner transmits the key code (which corresponds to the decoded ASCII function code) to the terminal. ASCII function codes are represented by the HEX values 00–1F. (Charts of these function codes are shown in Section 6, Supported Interface Keys.)
✱ Enable 2–10
SCANTEAM 5700 User’s Guide
Disable
Page 35
✱ Default All Serial Communication Settings ✱
CTS Check Selection This selection allows you to select the software programming feature that checks for a CTS signal, if your application does not have a CTS I/O line. Default = Disable.
Enable
✱ Disable
Baud Rate Selection This selection sets the baud rate from 300 bits per second to 38,400 bits per second. Programming baud rate causes the data to be sent at the specified rate. The host terminal must be set up for the same baud rate as the scanner, to ensure reliable communication. Default = 9600 bps.
300
600
1200
2400
4800
✱ 9600
19200
38400
SCANTEAM 5700 User’s Guide
2–11
Page 36
RS-232 Word Length Selection This selection allows you to set the RS-232 word length at seven or eight bits of data per character. The number of start and stop bits is fixed at one each. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.
✱ 7 Data, 1 Stop
7 Data, 2 Stop
8 Data, 1 Stop
Parity Selection This selection provides a means of checking character bit patterns for validity. The scanner can be configured to operate under Even, Odd, Mark / None, or Space parity options. The host terminal must be set up for the same parity as the scanner, to ensure reliable communication.
None
2–12
Mark
Space
Odd
✱ Even SCANTEAM 5700 User’s Guide
Page 37
Protocol Selection This selection allows you to program the scanner for the protocol required by your application. The protocol is a set of rules concerning the exchange of data between serially communicating devices. The scanner supports Record, Xon / Xoff, and Ack / Nak protocols when receiving data from an RS-232 device.
✱ Record
Xon / Xoff
Ack / Nak
Serial Wedge Output Selection This selection allows you to select the serial output direction required by your application. P1 and P2 are serial wedge designations printed on the serial wedge cable. Usually, one goes to the host and one goes to the terminal, depending on your specific application and the serial wedge cable. Note: Serial Wedge programming is for scanner model –X3 only! The scanner must also be in Serial Wedge mode (Terminal I.D. 50).
✱ To P1
To P2
To P1 and P2
SCANTEAM 5700 User’s Guide
2–13
Page 38
Data Format Editor This selection provides editing of all input (scanned) data. All Industrial and Retail symbologies can be formatted. You may scan the Clear Data Format bar code if you are certain you want to delete or clear all formats. To make Data Format Editor selections, you must know the terminal type, code I.D., code length, and editor commands your application requires. Use the Alpha-numeric bar codes (inside back cover) to scan these options. Use the Data Format Editor by following the steps below: ➊ ➋ ➌
Scan the Enter Data Format bar code. Terminal Type Scan two bar codes that represent the terminal type (00-99[, see page 1–11 for Terminal I.D. list.) Code I.D. Refer to the Symbology chart (page 2–7), then scan two bar codes from the “Hex Value” column that represent the Code I.D. of the symbology you want formatted. (“All Symbologies” – hex value 99 – is not supported by Data Formatter.)
➍
Length Scan two numeric bar codes (inside back cover) for the bar code length you require (00-99[). Be sure to include spaces.
➎
Editor Command Sequences Refer to the Format Editor Commands chart (page 2–16). Scan two bar codes that represent the command you need.
➏
End Format (FF) Scan “F” twice to end Data Format Editor programming.
[ 99 is the Universal number, indicating all terminals and all code lengths.
2–14
SCANTEAM 5700 User’s Guide
Page 39
Status Check Scan the Show Formats bar code to transmit the existing Data Format Editor formats. One format per line will be printed out.
Show Formats
Require Data Format When disabled, the bar code data will be output to the host as scanned (including prefixes and suffixes). When enabled, all input data must conform to an edited format or the scanner will not transmit the input data to the host device.
✱ Disable
Enable
Data Format Editor See pages 2–14 and 2–16 through 2–17 for a description of this selection and examples.
Enter Data Format
Clear All Data Formats
SCANTEAM 5700 User’s Guide
2–15
Page 40
Format Editor Commands Chart Send Commands F1 Send all characters followed by “XX” key or function code, starting from current cursor position. Syntax = F1XX (XX = HEX ASCII character or function code 00–FE HEX). F2 Send “NN” characters followed by “XX” key or function code, starting from current cursor position. Syntax = F2NNXX (NN = number of characters 00–99 DEC, XX = HEX ASCII character or function code 00–EF HEX). F3 Send up to but not including “SS” character (Search and Send) starting from current cursor position, leaving cursor pointing to “SS” character followed by “XX” key or function code. Syntax = F3SSXX (SS = HEX ASCII Character 00–7F HEX, XX = HEX ASCII character 00–7F HEX). F4 Send “XX” character “NN” times (Insert) leaving cursor in current cursor position. Syntax = F4XXNN (XX = HEX ASCII character 00–7F HEX, NN = number of characters 00–99 DEC).
Move Commands F5 Move cursor ahead “NN” characters from current cursor position. Syntax = F5NN (NN = number of characters 00–99 DEC). F6 Move cursor back “NN” characters from current cursor position. Syntax = F6NN (NN = number of characters 00–99 DEC). F7 Move cursor to the beginning of the data string. Syntax = F7.
Search Commands F8 Search ahead for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F8XX (XX = HEX ASCII character 00–7F). F9 Search back for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F9XX (XX = HEX ASCII character 00–7F).
Miscellaneous Commands FA Leading zero suppress on. Suppress leading zeroes from current cursor position until first non–zero character. Syntax = FA. FB Suppress “XX” character(s) (up to three) starting from current cursor position until suppress disable command “FC” or end of format. Syntax = FBXXFB, FBXXXXFB, FBXXXXXXFB (XX = ASCII character 00–7F). FC Disable suppress filter and clear all suppressed characters. Syntax = FC. FE Compare character in current cursor position to the character “XX.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FEXX (XX = HEX ASCII character 00 –7F).
2–16
SCANTEAM 5700 User’s Guide