Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 10

SCANTEAM 5700 Decoded Output User's Guide, pages 21 to 30

Pages 21 to 30 of 98

The original document is the PDF (913 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST5700

Page 21

Reset Factory Settings Scanning the Factory Default Settings bar code resets the scanner to the original factory settings, clearing any programming changes you may have made.

Factory Default Settings

Status Check Scan the Show Software Revision bar code to transmit the software revision level to the host terminal. The software revision will be printed out as “WA34310XXX.” (The “X’s” will vary according to the firmware ID.)

Show Software Revision

Quick Suffix Selections If your application requires it, scan the Program Carriage Return Suffix bar code to program a carriage return (CR) suffix for all enabled bar code symbologies. Scanning this bar code clears all previously programmed prefixes and suffixes. Scan the Clear Bar Code Suffix bar code to disable (or clear) all previously programmed prefixes and suffixes (e.g., the carriage return suffix).

Program Carriage Return Suffix

Clear Bar Code Suffix

SCANTEAM 5700 User’s Guide

1–13

Page 22

Scanner models 5700–X1 and 5700/X–X2 support the dual interface option allowing you to connect to two different terminals by switching interface cables. This option supports interfaces common to portable data terminals.

Dual Interface Programming Instructions To program the scanner for secondary interface, follow the steps below. (Dual Interface single scan programming codes are shown on the following pages.)

➊

While the scanner is connected to the primary terminal interface, scan one of the single bar codes on 1–15 to enable the secondary interface.

➋

Disconnect the primary interface cable from the scanner and attach the secondary interface cable.

➌

Attach the secondary interface cable to the secondary terminal and power up the terminal.

➍

Program the desired programmable selections for the secondary interface.

Dual Interface Programming Notes: •

To change the secondary interface from one selection to another (e.g., from HHLC to RS-232), the scanner must be reconnected to the primary interface, and then reprogrammed for the new secondary interface. Connect the scanner to the primary interface cable. Follow steps 1–4 above.

•

Scanning “Plug and Play” bar codes (single scan terminal selection bar codes), or changing the terminal type does not affect Dual Interface settings.

•

RS-232 programmable selections are used by both the primary and secondary interfaces. Changing an RS-232 parameter (e.g., baud rate or parity), while in primary or secondary mode will affect both interfaces.

•

The Switch Power feature is a low power sleep mode which is automatically enabled when the secondary interface cable is attached and the unit is programmed for a second interface. The option is enabled when the unit is shipped.

Note: Dual Interface selection is not available if the scanner is programmed for an HP terminal with a Terminal I.D. of 20 or 79, or for a WYSE terminal with a Terminal I.D. of 13–18.

[ Note: Section 2 contains information about Dual Interface Prefix/Suffix programming.

1–14

SCANTEAM 5700 User’s Guide

Page 23

Code 39 Wand Emulation Selection

✱ Code 39 Wand Emulation Selection

Same Code Wand Emulation Selection

Same Code Wand Emulation Selection [

RS-232 Selection

RS-232 Selection

Laser Emulation Selection

Laser Emulation Selection

Note: 5700–X3 units do not support Dual Interface. [ Supports Code 39, UPC, EAN, Code 128, Interleaved 2 of 5, and Codabar. All other codes output as Code 39.

SCANTEAM 5700 User’s Guide

1–15

Page 24

Dual Interface Enable/Disable Selection Dual Interface Disable Selection lets you temporarily disable the dual interface selection, while retaining your secondary interface setup in memory. If you want to enable the secondary interface again, scan the Enable Dual Interface bar code below.

✱ Disable

Enable

Switched Power Mode Selections When this feature is enabled, the unit consumes less than 50 uA from its power line when the trigger is not pulled. When the trigger is pulled, it consumes normal power. This feature is used for battery powered devices to save power. If power savings is not an issue and speed is, disable this feature for better performance.

✱ Switched Power (Low Power) Mode

Constant Power Mode

Laser Emulation Power Up Delay Selection Scan the Laser Emulation Power Up Delay bar code to delay full power up. This allows the PDT terminal to power up on scanner trigger. The PDT powers down between scans, greatly extending battery life. Scan two of the Numeric Bar Codes on the Programming Chart (inside back cover) to set the delay to any value between 00 and 99. 00–99 is the multiplier (x5ms).

Power Up Delay

1–16

SCANTEAM 5700 User’s Guide

Page 25

Section 2

Serial Interface Menu

Introduction Use this chapter to program the output parameters for the Hand-Held Laser Scanner. This programming section contains the following menuing selections: • Prefix and Suffix • Output • Serial Communication (RS-232) • Data Formatter

SCANTEAM 5700 User’s Guide

2–1

Page 26

Primary Interface Prefix and Suffix The scanner transmits a decoded message after every successful bar code read. Prefix and Suffix characters are data characters you may assign to be sent before and after the transmitted bar code data. Transmitted data frame –>

Prefix

Bar Code Message

Suffix

Characters for the Prefix and Suffix are selected by their hexadecimal ASCII value, up to 12 characters each. Prefix and Suffix characters may be sent for a specific symbology, or may be sent with all bar code scans. Default Prefix = none. Default Suffix = none.

Programming Steps to Add a Primary Interface Prefix / Suffix: ➊

To add a Prefix, scan the Add Primary Prefix programming bar code. To add a Suffix, scan the Add Primary Suffix programming bar code.

➋

Refer to the Symbology Chart (page 2–7) to find the Hex value that represents the symbology(s) you want transmitted with one or more Prefixes or Suffixes. Scan the two digits on the Programming Chart (on the inside of the back cover of this menu).

➌

Refer to the Hex ASCII Chart (page 2–7) to find the Hex value that represents the ASCII characters you wish to transmit with the bar code data. Use the Programming Chart (inside back cover) to scan the alphanumeric combination that represents the ASCII characters.

➍

To complete Prefix / Suffix programming, scan either: H Save Current Prefix or Suffix Changes[ programming bar code. This exits, saving the Prefix / Suffix selections you just assigned. H Discard Current Prefix or Suffix Changes programming bar code. This exits without changing the Prefix / Suffix.

[ You may also start scanning bar codes; your Prefix / Suffix selections will be saved.

Programming Steps to Clear (or Delete) One Prefix / Suffix Entry: ➊

➋ ➌

To clear the Prefix entry for a specific symbology, scan the Clear One Primary Prefix programming bar code. To clear the Suffix entry for a specific symbology, scan the Clear One Primary Suffix programming bar code. Refer to the Symbology Chart to find the Hex value representing the symbology’s entry you want cleared. Scan the two digits on the Programming Chart (on the inside of the back cover of this menu). You don’t need to scan Save Current ... Changes or Discard Current ... Changes programming bar codes to complete programming.

Other Programming Selections: Scanning the Clear All Primary Prefixes or Clear All Primary Suffixes bar code deletes all Primary Prefix or Suffix selections. You don’t need to scan the Save Current ... Changes or Discard Current ... Changes programming bar code to complete programming. Note: Prefix / Suffix programming examples may be found on page 2–6.

2–2

SCANTEAM 5700 User’s Guide

Page 27

Primary Interface Prefix Selection

Add Primary Prefix ]

Clear All Primary Prefixes

Clear One Primary Prefix ]

Primary Interface Suffix Selection

Add Primary Suffix ]

Clear All Primary Suffixes

Clear One Primary Suffix ]

Exit Selection for Prefix / Suffix Save Current Prefix or Suffix Changes

Discard Current Prefix or Suffix Changes

] One or more two-digit numbers are required after scanning this programming bar code. Please scan your selection on the Programming Chart (inside back cover).

SCANTEAM 5700 User’s Guide

2–3

Page 28

Secondary (Dual) Interface Prefix and Suffix The scanner will transmit a decoded message after every successful bar code read. Prefix and Suffix characters are data characters you may assign to be sent before and after the transmitted bar code data. Transmitted data frame –>

Prefix

Bar Code Message

Suffix

Characters for the Prefix and Suffix are selected by their hexadecimal ASCII value, up to 12 characters each. Prefix and Suffix characters may be sent for a specific symbology, or may be sent with all bar code scans. Default Prefix = none. Default Suffix = none.

Programming Steps to Add a Secondary (Dual) Interface Prefix / Suffix: ➊

To add a Prefix, scan the Add Secondary Prefix programming bar code. To add a Suffix, scan the Add Secondary Suffix programming bar code.

➋

Refer to the Symbology Chart (page 2–7) to find the Hex value that represents the symbology(s) you want transmitted with one or more Prefixes or Suffixes. Scan the two digits on the Programming Chart (on the inside of the back cover of this menu).

➌

Refer to the Hex ASCII Chart (page 2–7) to find the Hex value that represents the ASCII characters you wish to transmit with the bar code data. Use the Programming Chart (inside back cover) to scan the alphanumeric combination that represents the ASCII characters.

➍

To complete Prefix / Suffix programming, scan either: H Save Current Prefix or Suffix Changes[ programming bar code. This exits, saving the Prefix / Suffix selections you just assigned. H Discard Current Prefix or Suffix Changes programming bar code. This exits without changing the Prefix / Suffix.

[ You may also start scanning bar codes; your Prefix / Suffix selections will be saved.

Programming Steps to Clear (or Delete) One Prefix / Suffix Entry: ➊

➋ ➌

To clear the Prefix entry for a specific symbology, scan the Clear One Secondary Prefix programming bar code. To clear the Suffix entry for a specific symbology, scan the Clear One Secondary Suffix programming bar code. Refer to the Symbology Chart to find the Hex value representing the symbology’s entry you want cleared. Scan the two digits on the Programming Chart (on the inside of the back cover of this menu). You don’t need to scan Save Current ... Changes or Discard Current ... Changes programming bar codes to complete programming.

Other Programming Selections: Scanning the Clear All Secondary Prefixes or Clear All Secondary Suffixes bar code deletes all Secondary Prefix or Suffix selections. You don’t need to scan the Save Current ... Changes or Discard Current ... Changes programming bar code to complete programming. Note: Prefix / Suffix programming examples may be found on page 2–6.

2–4

SCANTEAM 5700 User’s Guide

Page 29

Secondary Interface Prefix Selection

Add Secondary Prefix ]

Clear All Secondary Prefixes

Clear One Secondary Prefix ]

Secondary Interface Suffix Selection

Add Secondary Suffix ]

Clear All Secondary Suffixes

Clear One Secondary Suffix ]

Exit Selection for Prefix / Suffix Save Current Prefix or Suffix Changes

Discard Current Prefix or Suffix Changes

] One or more two-digit numbers are required after scanning this programming bar code. Scan your selection on the Programming Chart (inside back cover).

SCANTEAM 5700 User’s Guide

2–5

Page 30

Prefix and Suffix Examples Example 1: Add Suffix for Specific Symbology You want to send a CR (carriage return) Suffix for UPC only. H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value of UPC is “63”. Scan 6 and 3 on the Programming Chart (inside back cover). H A “CR” is equivalent to “0D” (see the Hex ASCII Chart). Scan 0 and D on the Programming Chart. H Scan the Save Current Suffix Changes Exit Selection bar code.

Example 2: Add Suffix for ALL Symbologies You want to send a CR (carriage return) Suffix for all symbologies. H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value for All Symbologies is “99”. Scan 9 and 9 on the Programming Chart. H A “CR” is equivalent to “0D”. Scan 0 and D on the Programming Chart. H Scan the Save Current Suffix Changes Exit Selection bar code.

Example 3: Add Prefix for Specific Symbology / Suffix for ALL Symbologies You want to send a HT (tab) Prefix for UPC only and a CR / LF (carriage return / line feed) Suffix for all symbologies. H Scan the Add Prefix Prefix Selection bar code. H The Symbology Chart indicates that the Hex value of UPC is “63”. Scan 6 and 3 on the Programming Chart. H An “HT” is equivalent to “09”. Scan 0 and 9 on the Programming Chart. H Scan the Add Suffix Suffix Selection bar code. H The Symbology Chart indicates that the Hex value for All Symbologies is “99”. Scan 9 and 9 on the Programming Chart. H A “CR” is equivalent to “0D” and an “LF” is “0A”. Scan 0, D, 0, and A on the Programming Chart. H Scan the Save Current Prefix / Suffix Changes Exit Selection bar code.

Example 4: To Clear a Specific Prefix Entry You’ve programmed the scanner to send a CR / LF (carriage return / line feed) Prefix for all symbologies (Hex value, 99). This is one Prefix entry. You’ve also programmed a “#” Prefix for UPC (Hex, 63). You decide that you want to clear the UPC entry, but not the Prefix entry for all symbologies. H Scan the Clear Specific Prefix Prefix Selection bar code. H The Symbology Chart indicates that the Hex value for UPC is “63”. Scan 6 and 3 on the Programming Chart.

2–6

SCANTEAM 5700 User’s Guide