The text of a manual · part 4 of 10
SCANTEAM 3400 PDF User's Guide, pages 31 to 40
Pages 31 to 40 of 96
The original document is the PDF (823 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the HHP ST3400
Page 31
Output Selections
Scan Voting Selection
When Scan Voting is enabled, the scanner requires three (3) identical, consecutive scans before the bar code data will be accepted and transmitted to the terminal. When this selection is disabled, the bar code data will be transmitted following one (1) valid scan.
)
Enable * Disable | Code LD. Transmit Selection |
This selection allows you to enable or disable transmission of a Code |.D. before the decoded bar code symbology. (See the Symbology Chart on page 2-6 for the single character code that identifies each symbology.)
Enable * Disable | AIM LD. Transmit Selection |
This selection allows you to enable or disable transmission of an AIM |.D. before the decoded bar code symbology. (See AIM Guidelines on Symbology Identifiers for more information on the AIM symbology ID characters.) Default
= Disable.
Enable * Disable
Function Code Transmit Selection |
When this selection is enabled, and function codes are contained within the scanned data, the scanner transmits the key code (which corresponds to the decoded ASCII function code) to the terminal. ASCII function codes are represented by the HEX values 00 - 1F. (Charts of these function codes are shown in Section 6, Supported Interface Keys.)
SCANTEAM 3400PDF User’s Guide 2-11
* Enable Disable
Page 32
✱ Default All Serial Communication Settings ✱
CTS Check Selection *"' &"
- *"'$ !"& - Default = Disable.
✱
Baud Rate Selection
&"
&" -& '%& '# %- -% &" Default = 9600 bps.
2–12
✱
-
SCANTEAM 3400PDF User’s Guide
Page 33
Serial Communication Settings RS-232 Word Length Selection
This selection allows you to set the RS-232 word length at seven or eight bits of data per character. The number of start and stop bits is fixed at one each. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.
* 7 Data, 1 Stop
7 Data, 2 Stop 8 Data, 1 Stop
SCANTEAM 3400PDF User’s Guide 2-13
Page 34
Serial Communication Settings
Parity Selection
This selection provides a means of checking character bit patterns for validity. The scanner can be configured to operate under Even, Odd, Mark / None, or Space parity options. The host terminal must be set up for the same parity as the scanner, to ensure reliable communication.
None
Mark Space
Odd * Even
| Protocol Selection |
This selection allows you to program the scanner for the protocol required by your application. The protocol is a set of rules concerning the exchange of data between serially communicating devices. The scanner supports Record, Xon / Xoff, and Ack / Nak protocols when receiving data from an RS-232 device.
| | | ™ | il | | |
Xon / Xoff Ack / Nak
2-14 SCANTEAM 3400PDF User’s Guide
Page 35
Data Formatter Selections
Data Format Editor
Note: The Data Formatter option may be used with linear codes only.
This selection provides editing of all input (scanned) data. All Industrial and Retail symbologies can be formatted. You may scan the Clear Data Format bar code if you are certain you want to delete or clear all formats.
To make Data Format Editor selections, you must know the terminal type, code 1.D., code length, and editor commands your application requires. Use the Alpha-numeric bar codes on the Programming Chart on the next page to scan these options.
Use the Data Format Editor by following the steps below:
@ Scan the Enter Data Format bar code.
@ Terminal Type Scan two bar codes that represent the terminal type (00-99, see page 1 - 9 for Terminal I.D. list.)
® Code I.D. Refer to the Symbology chart (page 2 - 6), then scan two bar codes from the “Hex Value” column that represent the Code I.D. of the symbology you want formatted. (“All Symbologies”, hex value 99, is not supported by Data Formatter.)
® Length Scan two numeric bar codes on the next page for the bar code length you require (00-99}). Be sure to include spaces.
@® Editor Command Sequences Refer to the Format Editor Commands chart (page 2 - 18). Scan two bar codes that represent the command you need.
@_ End Format (FF) Scan “F” twice to end Data Format Editor programming.
+ 99 is the Universal number, indicating all terminals and all code lengths.
SCANTEAM 3400PDF User’s Guide 2-15
Page 36
Programming Chart
HI 0 IMM 2 I IMI 6 IMM 8 Iti A Hil Cc IM E
4
Ia 1 Hi 3 Hil 5 Mi IM 9 Hh B Hh D IM F
7
SCANTEAM 3400PDF User’s Gu ide
Page 37
Data Formatter Selections
Status Check
Scan the Show Formats bar code to transmit the existing Data Format Editor formats. One format per line will be printed out.
Show Formats Require Data Format
When disabled, the bar code data will be output to the host as scanned (including prefixes and suffixes). When enabled, all input data must conform to an edited format or the scanner will not transmit the input data to the host device.
Enable * Disable | Data Format Editor
See pages 2 - 15 and 2 - 18 through 2 - 19 for a description of this selection and examples.
Enter Data Format Clear All Data Formats
SCANTEAM 3400PDF User’s Guide 2-17
Page 38
Format Editor Commands Chart Send Commands F1 Send all characters followed by key or function code, starting from current cursor position. Syntax = F1XX (XX = HEX ASCII character or function code 00-FE HEX). F2 Send characters followed by key or function code, starting from current cursor position. Syntax = F2NNXX (NN = number of characters 00-99 DEC, XX = HEX ASCII character or function code 00-EF HEX). F3 Send up to but not including character (Search and Send) starting from current cursor position, leaving cursor pointing to character followed by key or function code. Syntax = F3SSXX (SS = HEX ASCII Character 00-7F HEX, XX = HEX ASCII character 00-7F HEX). F4 Send character times (Insert) leaving cursor in current cursor position. Syntax = F4XXNN (XX = HEX ASCII character 00-7F HEX, NN = number of characters 00-99 DEC).
Move Commands F5 Move cursor ahead characters from current cursor position. Syntax = F5NN (NN = number of characters 00-99 DEC). F6 Move cursor back characters from current cursor position. Syntax = F6NN (NN = number of characters 00-99 DEC). F7 Move cursor to the beginning of the data string. Syntax = F7.
Search Commands F8 Search ahead for character from current cursor position, leaving cursor pointing to character. Syntax = F8XX (XX = HEX ASCII character 00-7F). F9 Search back for character from current cursor position, leaving cursor pointing to character. Syntax = F9XX (XX = HEX ASCII character 00-7F).
Miscellaneous Commands FA Leading zero suppress on. Suppress leading zeroes from current cursor position until first non-zero character. Syntax = FA. FB Suppress character(s) (up to three) starting from current cursor position until suppress disable command or end of format. Syntax = FBXXFB, FBXXXXFB, FBXXXXXXFB (XX = ASCII character 00-7F). FC Disable suppress filter and clear all suppressed characters. Syntax = FC. FE Compare character in current cursor position to the character If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FEXX (XX = HEX ASCII character 00 -7F).
2–18
SCANTEAM 3400PDF User’s Guide
Page 39
Data Formatter Selections
Data Formatter Example
You are using an IBM PC AT and are scanning a UPC A bar code with a five digit addenda (shown below). The bar code has a total of 18 characters, including the number system, the check digits, and a space between the main bar code data and the addenda bar code data.
UPC A with 5 digit addenda
0 12345 67890 5
For your application, you don’t want the space between the main bar code data and the addenda bar code data transmitted. You also want the bar code data followed by a carriage return (CR).
Refer to the Format Editor Commands Chart on page 2-18 to format the following example. The programming bar codes on pages 2-17, and the alpha-numeric bar codes on the inside back cover are used to program the data formatter.
= Scan the Enter Data Format bar code (page 2-17).
Scan the 03 bar codes for PC AT Terminal Type.
Scan the 63 bar codes, the Hex value for UPC symbology. Scan the 18 bar codes for the bar code length.
The following are the Editor Command Sequences: = Scan the FB (suppress characters command) bar codes, scan 20 (the Hex value for a space), and then scan FB to frame (complete) the command.
= Scan the F7 bar codes to move the cursor back to the beginning of the bar code data.
= Scan the F1 and OD bar codes to send all the characters followed by a carriage return (CR= OD in Hex value).
m= Scan the FF bar codes to end Format Editor selection.
SCANTEAM 3400PDF User’s Guide 2-19
Page 40
2–20
SCANTEAM 3400PDF User’s Guide