The text of a manual · part 2 of 3
SCANTEAM 2380 Wand Programming Menu, pages 10 to 18
Pages 10 to 18 of 26
The original document is the PDF (252 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST2380
Page 10
COMM 1
SCANTEAM 2380 Information and Examples
INTERNATIONAL KEYBOARDS The unit aligns the keyboard layout based on the International Keyboard selected here.
INTERMEC COMPATIBILITY YES – Allows the unit to be compatible with Intermec keyboard function codes. NO – The default keyboard function codes that are in the preamble and postamble remain active at all times.
10
Page 11
COMM 1
SCANTEAM 2380 Programming Menu
USE THIS PAGE To select foreign keyboards. To enable Intermec compatibility scan selections
ENTER
INTERNATIONAL KEYBOARDS (3)
scan scan
DEFAULT
INTERMEC COMPATIBILITY (3)
variables scan scan
France
A
Germany
B
Spain
C
Switzerland
D
Italy
E
USA
F*
Sweden (4)
G
Canada (5)
H
Portugal (5)
I Yes/No* scan
EXIT
Notes: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples. (3) This programming feature is supported for Mask B and above, and only for an AT or VT Series keyboard. (4) Special download software required. (5) Only supported for VT Series keyboards.
11
Page 12
SCANCODE
SCANTEAM 2380 Information and Examples
SELECTION
K2 SCANCODE CAPABILITY Reconfigures the 2380 to use K2 (SCANTEAM 2300) compatible scancodes. If other Welch Allyn wedge products are being used or are planned for future use, it is strongly recommended to program this selection for “YES” and use the function codes found in the Keyboard Function Codes Table 2 and Table 3 in the Appendix A.8 of the 2380Technical Manual. Otherwise, the 2380 will be programmed to use function codes in Keyboard Function Codes Table 1 in the Appendix A.8 of the 2380 Technical Manual.
NEW KEYBOARD SCANCODE TABLE If the SCANTEAM 2380 has been downloaded to contain another scancode table, programming this selection to “YES” will cause the new scancode table to be used, rather than the normal scancode table. This menu selection is applicable for use with terminals not equipped with standard manufacturers’ keyboards (that is, foreign keyboards).
BEEP PC When programmed on, beeps the PC on a good read.
NUMERIC KEYPAD When “main keyboard numbers” is selected, numbers will be sent to the host terminal as if keyed in from the main keyboard. If “numeric keypad” is enabled, numbers will be sent as if keyed in from the numeric keypad.
RX INTERRUPT Occasionally, keyboard activity before a bar code is scanned will cause the wand to beep intermittently or turn off. This selection will prevent this from happening.
12
Page 13
SCANCODE
SCANTEAM 2380 Programming Menu
SELECTION
USE THIS PAGE (3) To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To reconfigure the 2380 to use the 2380 Function Codes. (Applies only to IBM XT, AT, and PS/2’s.) Refer to Appendix A.8 in 2380 Technical Manual for two options. To reconfigure the 2380 to use a new Scancode Table. Only applicable to customers who request new Scancode Table (that is, foreign keyboards).
scan
ENTER scan selections scan variables
K2 SCANCODE CAPABILITY
Yes/No*
NEW KEYBOARD SCANCODE TABLE
Yes/No*
BEEP PC (4, 6)
Yes/No*
NUMERIC KEYPAD (5, 6)
Main Keyboard Numbers Numeric Keypad
DEFAULT scan
RX INTERRUPT (6, 7, 8)
scan scan
A* B Yes/No*
Notes: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples. (3) This page does not apply to SCANTEAM 2380’s with item numbers 022410, 022537, and 022538. (4) “Beep PC” must be disabled (“No”) when “Beep on Reset” (OUTPUT PARAMETERS page) is enabled. (5) The master DEFAULT bar code on this page does not return these parameters to their default setting. (6) This programming feature is not supported in all models/software revisions. (7) RX Interrupt must be enabled before attempting software upgrades. To download new software, enable RX Interrupt, power cycle scanner, then download. (8) Standard 2380 software prior to software revision 33961091 is defaulted ON. Later software revisions are defaulted OFF.
EXIT
13
Page 14
SYMBOLOGY SELECTION
SCANTEAM 2380 Information and Examples
INDUSTRIAL
INDUSTRIAL CODE OUTPUT FORMATS aSX . . . XS bSXX . . XXCS eXX . . . XXC fXX . . . . XX gXX . . . XX hXX . . . XXCC iXX . . . . XX jXX . . . . XX
CODABAR Code 3 of 9 INTERLEAVED 2 of 5 2 of 5 MSI Code 11 Code 93 Code 128 Where: a = Codabar Code ID b = Code 3 of 9 ID e = Interleaved 2 of 5 ID f = 2 of 5 ID g = MSI (Plessey) h = Code 11 ID i = Code 93 ID j = Code 128 ID S = Start/Stop Character X = Data Character C = Checksum Character
NOTE: Proper parameters must be turned on for code identification. Start/stop and Checksum characters to be transmitted. For maximum data security, disable the Codes not used.
FULL ASCII CODE 3 OF 9 CHARACTERS If full ASCII Code 3 of 9 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN and /C will be decoded as the ASCII character #. FULL ASCII CODE 3 OF 9 CHART NUL %U SOH $A STX $B ETX $C EOT $D ENQ $E ACK $F BEL $G BS $H HT $I LF $J VT $K FF $L CR $M SO $N SI $O
DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
$P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E
SP ! ” # $ % & ’ ( ) * + , – . /O
SPACE /A /B /C /D /E /F /G /H /I /J /K /L – . /
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J
@ A B C D E F G H I J K L M N O
%V A B C D E F G H I J K L M N O
P Q R S T U V W X Y Z [ \ ] ^ _
P Q R S T U V W X Y Z %K %L %M %N %0
‘ a b c d e f g h i j k l m n o
%W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O p +P q +Q r +R s +S t +T u +U v +V w +W x +X y +Y z +Z { %P | %Q } %R ~ %S DEL %T%X%Y%Z
Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.
MIN/MAX LENGTH These variables are used to require that bar code symbols contain a character count within a certain range. Bar codes with counts outside this range will not be decoded. EXAMPLE: Decode only those bar codes with a count of 9–20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
14
Page 15
SYMBOLOGY
SCANTEAM 2380 Programming Menu
SELECTION
(CODES)
USE THIS PAGE To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To specify desired bar code symbologies. To select symbology options.
selections scan
CODABAR
CODE 39 scan (ID = a)
(ID = b)
I
II
ENTER scan
UPC
(ID =c )
III
DEFAULT
EAN
(ID = d)
IV
UPC and/or EAN INTERLEAVED (ID = e) 2 OF 5
V
CODE 2 OF 5 (ID = f)
VI
MSI CODE 93 CODE 128
CODE 11 (3)
(ID = g) (ID = i) (ID = j)
(ID = h)
VII VIII IX
X variables Enable Minimum Length Maximum Length S/S Xmit
EXIT scan
A B C
*Yes/No *01–MAX Min–48* *Yes/No
Enable Minimum Length Maximum Length S/S Xmit Check Char. Req’d Xmit Check Char. Full ASCII Append Option
D E F G
*Yes/No *00–MAX Min–48* Yes/No* Yes/No* Yes/No* *Yes/No Yes/No*
Version A
A
*Yes/No
Version E (Version E Expand) Number System Xmit Check Digit Xmit
B C D E
*Yes/No Yes/No* *Yes/No Yes/No*
EAN/JAN 13 EAN/JAN 8
A B
*Yes/No *Yes/No
2–Digit Addenda 5–Digit Addenda
F G
*Yes/No *Yes/No
Enable Minimum Length (2) Maximum Length 6, 14 & 16 Only Check Digit Req’d Xmit Check Char.
A B C D E
*Yes/No 02–MAX Min–64* Yes/No* Yes/No* Yes/No*
Enable Minimum Length (2) Maximum Length
A B
*Yes/No 02–MAX Min–64*
Enable Minimum Length Maximum Length
A B
*Yes/No *04–MAX Min–48*
Enable Minimum Length Maximum Length
A B
*Yes/No *00–MAX Min–60*
Enable (All Modes) Mode A Mode B Mode C Minimum Length Maximum Length Leading <FNC1> Req’d.
A B C D E F
*Yes/No *Yes/No *Yes/No *Yes/No *00–Max Min–80* Yes/No*
A
Yes/No*
Xmit Check Char.
B
Yes/No*
Minimum Length Maximum Length
C D
*01–MAX Min–48*
A B C
Enable 2 Check Digits (N=1)
scan scan
*Yes/No
Notes: (1) * Designates DEFAULT selections. (2) The DEFAULT Minimum Length for 2/5 codes is 4 Characters. (3) This programming feature is not supported in all models/software revisions.
15
Page 16
SYMBOLOGY SELECTION
SCANTEAM 2380 Information and Examples
RETAIL
RETAIL CODE OUTPUT FORMATS Non–Zero Suppressed UPC–A and UPC–E Output Format cNXXXXXXXXXXC UPC–A cNXXXXXXXXXXC–SS UPC–A with 2 digit supplemental cNXXXXXXXXXXC–SSSSS UPC–A with 5 digit supplemental cNXXXXXXXXXXC UPC–E cNXXXXXXXXXXC–SS UPC–E with 2 digit supplemental cNXXXXXXXXXXC–SSSSS UPC–E with 5 digit supplemental Zero Suppressed UPC–A and UPC–E Output Format cNXXXXXXXXXXC UPC–A cNXXXXXXXXXXC–SS UPC–A with 2 digit supplemental cNXXXXXXXXXXC–SSSSS UPC–A with 5 digit supplemental cNXXXXXX UPC–E cNXXXXXX–SS UPC–E with 2 digit supplemental cNXXXXXX–SSSSS UPC–E with 5 digit supplemental EAN/JAN Output Format EAN/JAN–13 EAN/JAN–13 with 2 digit supplemental EAN/JAN–13 with 5 digit supplemental EAN/JAN–8 EAN/JAN–8 with 2 digit supplemental EAN/JAN–8 with 5 digit supplemental dffXXXXXXXXXXC dffXXXXXXXXXX–SS dffXXXXXXXXXX–SSSSS dffXXXXXC dffXXXXXC–SS dffXXXXXC–SSSSS
Where: c = UPC Code ID d = EAN/JAN Code ID N = Number System Character f = Identification Flag X = Data Character C = Checksum Character – = Space S = Supplemental Character NOTE: Proper parameters must be turned on for code identification, number system, checksum and supplemental characters to be transmitted. For maximum data security, disable the Codes not used.
UPC/EAN LENGTH CHART Basic Length
W/out Ck. Digit
W/out # Sys. Digit
W/2 Digit Addendum
W/5 Digit Addendum
UPCA
12
–01
–01
+02
+05
UPCE [w/ 0’s suppressed]
8
–01
–01
+02
+05
UPCE [expanded]
12
–01
–01
+02
+05
UPCD1
14
–01
–01
+02
+05
UPCD2
20
–02
–01
+02
+05
UPCD3
24
–02
–01
+02
+05
UPCD4
28
–03
–01
+02
+05
UPCD5
32
–03
–01
+02
+05
EAN8
8
–01
N/A
+02
+05
EAN13
13
–01
N/A
+02
+05 selections
16
TOTAL
Page 17
SYMBOLOGY
SCANTEAM 2380 Programming Menu
SELECTION
(CODES)
USE THIS PAGE To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To specify desired bar code symbologies. To select symbology options.
selections scan scan CODABAR
ENTER
CODE 39
(ID = a)
(ID = b)
I
II scan
DEFAULT
UPC
EAN
(ID =c )
(ID = d)
III
IV
UPC and/or EAN INTERLEAVED (ID = e) 2 OF 5
V
CODE 2 OF 5 (ID = f)
VI
MSI CODE 93 CODE 128
CODE 11 (3)
(ID = g) (ID = i) (ID = j)
(ID = h)
VII VIII IX
X variables Enable Minimum Length Maximum Length S/S Xmit
EXIT scan
A B C
*Yes/No *01–MAX Min–48* *Yes/No
Enable Minimum Length Maximum Length S/S Xmit Check Char. Req’d Xmit Check Char. Full ASCII Append Option
D E F G
*Yes/No *00–MAX Min–48* Yes/No* Yes/No* Yes/No* *Yes/No Yes/No*
Version A
A
*Yes/No
Version E (Version E Expand) Number System Xmit Check Digit Xmit
B C D E
*Yes/No Yes/No* *Yes/No Yes/No*
EAN/JAN 13 EAN/JAN 8
A B
*Yes/No *Yes/No
2–Digit Addenda 5–Digit Addenda
F G
*Yes/No *Yes/No
Enable Minimum Length (2) Maximum Length 6, 14 & 16 Only Check Digit Req’d Xmit Check Char.
A B C D E
*Yes/No 02–MAX Min–64* Yes/No* Yes/No* Yes/No*
Enable Minimum Length (2) Maximum Length
A B
*Yes/No 02–MAX Min–64*
Enable Minimum Length Maximum Length
A B
*Yes/No *04–MAX Min–48*
Enable Minimum Length Maximum Length
A B
*Yes/No *00–MAX Min–60*
Enable (All Modes) Mode A Mode B Mode C Minimum Length Maximum Length Leading <FNC1> Req’d.
A B C D E F
*Yes/No *Yes/No *Yes/No *Yes/No *00–Max Min–80* Yes/No*
A
Yes/No*
Xmit Check Char.
B
Yes/No*
Minimum Length Maximum Length
C D
*01–MAX Min–48*
A B C
Enable 2 Check Digits (N=1)
scan scan
*Yes/No
Notes: (1) * Designates DEFAULT selections. (2) The DEFAULT Minimum Length for 2/5 codes is 4 Characters. (3) This programming feature is not supported in all models/software revisions.
17
Page 18
USER’S NOTES
18
SCANTEAM 2380 Programming Menu