Page 10

COMM 1

SCANTEAM 2380 Information and Examples

INTERNATIONAL KEYBOARDS The unit aligns the keyboard layout based on the International Keyboard selected here.

INTERMEC COMPATIBILITY YES – Allows the unit to be compatible with Intermec keyboard function codes. NO – The default keyboard function codes that are in the preamble and postamble remain active at all times.

10

Page 11

COMM 1

SCANTEAM 2380 Programming Menu

USE THIS PAGE To select foreign keyboards. To enable Intermec compatibility scan selections

ENTER

INTERNATIONAL KEYBOARDS (3)

scan scan

DEFAULT

INTERMEC COMPATIBILITY (3)

variables scan scan

France

A

Germany

B

Spain

C

Switzerland

D

Italy

E

USA

F*

Sweden (4)

G

Canada (5)

H

Portugal (5)

I Yes/No* scan

EXIT

Notes: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples. (3) This programming feature is supported for Mask B and above, and only for an AT or VT Series keyboard. (4) Special download software required. (5) Only supported for VT Series keyboards.

11

Page 12

SCANCODE

SCANTEAM 2380 Information and Examples

SELECTION

K2 SCANCODE CAPABILITY Reconfigures the 2380 to use K2 (SCANTEAM 2300) compatible scancodes. If other Welch Allyn wedge products are being used or are planned for future use, it is strongly recommended to program this selection for “YES” and use the function codes found in the Keyboard Function Codes Table 2 and Table 3 in the Appendix A.8 of the 2380Technical Manual. Otherwise, the 2380 will be programmed to use function codes in Keyboard Function Codes Table 1 in the Appendix A.8 of the 2380 Technical Manual.

NEW KEYBOARD SCANCODE TABLE If the SCANTEAM 2380 has been downloaded to contain another scancode table, programming this selection to “YES” will cause the new scancode table to be used, rather than the normal scancode table. This menu selection is applicable for use with terminals not equipped with standard manufacturers’ keyboards (that is, foreign keyboards).

BEEP PC When programmed on, beeps the PC on a good read.

NUMERIC KEYPAD When “main keyboard numbers” is selected, numbers will be sent to the host terminal as if keyed in from the main keyboard. If “numeric keypad” is enabled, numbers will be sent as if keyed in from the numeric keypad.

RX INTERRUPT Occasionally, keyboard activity before a bar code is scanned will cause the wand to beep intermittently or turn off. This selection will prevent this from happening.

12

Page 13

SCANCODE

SCANTEAM 2380 Programming Menu

SELECTION

USE THIS PAGE (3) To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To reconfigure the 2380 to use the 2380 Function Codes. (Applies only to IBM XT, AT, and PS/2’s.) Refer to Appendix A.8 in 2380 Technical Manual for two options. To reconfigure the 2380 to use a new Scancode Table. Only applicable to customers who request new Scancode Table (that is, foreign keyboards).

scan

ENTER scan selections scan variables

K2 SCANCODE CAPABILITY

Yes/No*

NEW KEYBOARD SCANCODE TABLE

Yes/No*

BEEP PC (4, 6)

Yes/No*

NUMERIC KEYPAD (5, 6)

Main Keyboard Numbers Numeric Keypad

DEFAULT scan

RX INTERRUPT (6, 7, 8)

scan scan

A* B Yes/No*

Notes: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples. (3) This page does not apply to SCANTEAM 2380’s with item numbers 022410, 022537, and 022538. (4) “Beep PC” must be disabled (“No”) when “Beep on Reset” (OUTPUT PARAMETERS page) is enabled. (5) The master DEFAULT bar code on this page does not return these parameters to their default setting. (6) This programming feature is not supported in all models/software revisions. (7) RX Interrupt must be enabled before attempting software upgrades. To download new software, enable RX Interrupt, power cycle scanner, then download. (8) Standard 2380 software prior to software revision 33961091 is defaulted ON. Later software revisions are defaulted OFF.

EXIT

13

Page 14

SYMBOLOGY SELECTION

SCANTEAM 2380 Information and Examples

INDUSTRIAL

INDUSTRIAL CODE OUTPUT FORMATS aSX . . . XS bSXX . . XXCS eXX . . . XXC fXX . . . . XX gXX . . . XX hXX . . . XXCC iXX . . . . XX jXX . . . . XX

CODABAR Code 3 of 9 INTERLEAVED 2 of 5 2 of 5 MSI Code 11 Code 93 Code 128 Where: a = Codabar Code ID b = Code 3 of 9 ID e = Interleaved 2 of 5 ID f = 2 of 5 ID g = MSI (Plessey) h = Code 11 ID i = Code 93 ID j = Code 128 ID S = Start/Stop Character X = Data Character C = Checksum Character

NOTE: Proper parameters must be turned on for code identification. Start/stop and Checksum characters to be transmitted. For maximum data security, disable the Codes not used.

FULL ASCII CODE 3 OF 9 CHARACTERS If full ASCII Code 3 of 9 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN and /C will be decoded as the ASCII character #. FULL ASCII CODE 3 OF 9 CHART NUL %U SOH $A STX $B ETX $C EOT $D ENQ $E ACK $F BEL $G BS $H HT $I LF $J VT $K FF $L CR $M SO $N SI $O

DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

$P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E

SP ! ” # $ % & ’ ( ) * + , – . /O

SPACE /A /B /C /D /E /F /G /H /I /J /K /L – . /

0 1 2 3 4 5 6 7 8 9 : ; < = > ?

0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J

@ A B C D E F G H I J K L M N O

%V A B C D E F G H I J K L M N O

P Q R S T U V W X Y Z [ \ ] ^ _

P Q R S T U V W X Y Z %K %L %M %N %0

‘ a b c d e f g h i j k l m n o

%W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O p +P q +Q r +R s +S t +T u +U v +V w +W x +X y +Y z +Z { %P | %Q } %R ~ %S DEL %T%X%Y%Z

Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.

MIN/MAX LENGTH These variables are used to require that bar code symbols contain a character count within a certain range. Bar codes with counts outside this range will not be decoded. EXAMPLE: Decode only those bar codes with a count of 9–20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

14

Page 15

SYMBOLOGY

SCANTEAM 2380 Programming Menu

SELECTION

(CODES)

USE THIS PAGE To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To specify desired bar code symbologies. To select symbology options.

selections scan

CODABAR

CODE 39 scan (ID = a)

(ID = b)

I

II

ENTER scan

UPC

(ID =c )

III

DEFAULT

EAN

(ID = d)

IV

UPC and/or EAN INTERLEAVED (ID = e) 2 OF 5

V

CODE 2 OF 5 (ID = f)

VI

MSI CODE 93 CODE 128

CODE 11 (3)

(ID = g) (ID = i) (ID = j)

(ID = h)

VII VIII IX

X variables Enable Minimum Length Maximum Length S/S Xmit

EXIT scan

A B C

*Yes/No *01–MAX Min–48* *Yes/No

Enable Minimum Length Maximum Length S/S Xmit Check Char. Req’d Xmit Check Char. Full ASCII Append Option

D E F G

*Yes/No *00–MAX Min–48* Yes/No* Yes/No* Yes/No* *Yes/No Yes/No*

Version A

A

*Yes/No

Version E (Version E Expand) Number System Xmit Check Digit Xmit

B C D E

*Yes/No Yes/No* *Yes/No Yes/No*

EAN/JAN 13 EAN/JAN 8

A B

*Yes/No *Yes/No

2–Digit Addenda 5–Digit Addenda

F G

*Yes/No *Yes/No

Enable Minimum Length (2) Maximum Length 6, 14 & 16 Only Check Digit Req’d Xmit Check Char.

A B C D E

*Yes/No 02–MAX Min–64* Yes/No* Yes/No* Yes/No*

Enable Minimum Length (2) Maximum Length

A B

*Yes/No 02–MAX Min–64*

Enable Minimum Length Maximum Length

A B

*Yes/No *04–MAX Min–48*

Enable Minimum Length Maximum Length

A B

*Yes/No *00–MAX Min–60*

Enable (All Modes) Mode A Mode B Mode C Minimum Length Maximum Length Leading <FNC1> Req’d.

A B C D E F

*Yes/No *Yes/No *Yes/No *Yes/No *00–Max Min–80* Yes/No*

A

Yes/No*

Xmit Check Char.

B

Yes/No*

Minimum Length Maximum Length

C D

*01–MAX Min–48*

A B C

Enable 2 Check Digits (N=1)

scan scan

*Yes/No

Notes: (1) * Designates DEFAULT selections. (2) The DEFAULT Minimum Length for 2/5 codes is 4 Characters. (3) This programming feature is not supported in all models/software revisions.

15

Page 16

SYMBOLOGY SELECTION

SCANTEAM 2380 Information and Examples

RETAIL

RETAIL CODE OUTPUT FORMATS Non–Zero Suppressed UPC–A and UPC–E Output Format cNXXXXXXXXXXC UPC–A cNXXXXXXXXXXC–SS UPC–A with 2 digit supplemental cNXXXXXXXXXXC–SSSSS UPC–A with 5 digit supplemental cNXXXXXXXXXXC UPC–E cNXXXXXXXXXXC–SS UPC–E with 2 digit supplemental cNXXXXXXXXXXC–SSSSS UPC–E with 5 digit supplemental Zero Suppressed UPC–A and UPC–E Output Format cNXXXXXXXXXXC UPC–A cNXXXXXXXXXXC–SS UPC–A with 2 digit supplemental cNXXXXXXXXXXC–SSSSS UPC–A with 5 digit supplemental cNXXXXXX UPC–E cNXXXXXX–SS UPC–E with 2 digit supplemental cNXXXXXX–SSSSS UPC–E with 5 digit supplemental EAN/JAN Output Format EAN/JAN–13 EAN/JAN–13 with 2 digit supplemental EAN/JAN–13 with 5 digit supplemental EAN/JAN–8 EAN/JAN–8 with 2 digit supplemental EAN/JAN–8 with 5 digit supplemental dffXXXXXXXXXXC dffXXXXXXXXXX–SS dffXXXXXXXXXX–SSSSS dffXXXXXC dffXXXXXC–SS dffXXXXXC–SSSSS

Where: c = UPC Code ID d = EAN/JAN Code ID N = Number System Character f = Identification Flag X = Data Character C = Checksum Character – = Space S = Supplemental Character NOTE: Proper parameters must be turned on for code identification, number system, checksum and supplemental characters to be transmitted. For maximum data security, disable the Codes not used.

UPC/EAN LENGTH CHART Basic Length

W/out Ck. Digit

W/out # Sys. Digit

W/2 Digit Addendum

W/5 Digit Addendum

UPCA

12

–01

–01

+02

+05

UPCE [w/ 0’s suppressed]

8

–01

–01

+02

+05

UPCE [expanded]

12

–01

–01

+02

+05

UPCD1

14

–01

–01

+02

+05

UPCD2

20

–02

–01

+02

+05

UPCD3

24

–02

–01

+02

+05

UPCD4

28

–03

–01

+02

+05

UPCD5

32

–03

–01

+02

+05

EAN8

8

–01

N/A

+02

+05

EAN13

13

–01

N/A

+02

+05 selections

16

TOTAL

Page 17

SYMBOLOGY

SCANTEAM 2380 Programming Menu

SELECTION

(CODES)

USE THIS PAGE To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To specify desired bar code symbologies. To select symbology options.

selections scan scan CODABAR

ENTER

CODE 39

(ID = a)

(ID = b)

I

II scan

DEFAULT

UPC

EAN

(ID =c )

(ID = d)

III

IV

UPC and/or EAN INTERLEAVED (ID = e) 2 OF 5

V

CODE 2 OF 5 (ID = f)

VI

MSI CODE 93 CODE 128

CODE 11 (3)

(ID = g) (ID = i) (ID = j)

(ID = h)

VII VIII IX

X variables Enable Minimum Length Maximum Length S/S Xmit

EXIT scan

A B C

*Yes/No *01–MAX Min–48* *Yes/No

Enable Minimum Length Maximum Length S/S Xmit Check Char. Req’d Xmit Check Char. Full ASCII Append Option

D E F G

*Yes/No *00–MAX Min–48* Yes/No* Yes/No* Yes/No* *Yes/No Yes/No*

Version A

A

*Yes/No

Version E (Version E Expand) Number System Xmit Check Digit Xmit

B C D E

*Yes/No Yes/No* *Yes/No Yes/No*

EAN/JAN 13 EAN/JAN 8

A B

*Yes/No *Yes/No

2–Digit Addenda 5–Digit Addenda

F G

*Yes/No *Yes/No

Enable Minimum Length (2) Maximum Length 6, 14 & 16 Only Check Digit Req’d Xmit Check Char.

A B C D E

*Yes/No 02–MAX Min–64* Yes/No* Yes/No* Yes/No*

Enable Minimum Length (2) Maximum Length

A B

*Yes/No 02–MAX Min–64*

Enable Minimum Length Maximum Length

A B

*Yes/No *04–MAX Min–48*

Enable Minimum Length Maximum Length

A B

*Yes/No *00–MAX Min–60*

Enable (All Modes) Mode A Mode B Mode C Minimum Length Maximum Length Leading <FNC1> Req’d.

A B C D E F

*Yes/No *Yes/No *Yes/No *Yes/No *00–Max Min–80* Yes/No*

A

Yes/No*

Xmit Check Char.

B

Yes/No*

Minimum Length Maximum Length

C D

*01–MAX Min–48*

A B C

Enable 2 Check Digits (N=1)

scan scan

*Yes/No

Notes: (1) * Designates DEFAULT selections. (2) The DEFAULT Minimum Length for 2/5 codes is 4 Characters. (3) This programming feature is not supported in all models/software revisions.

17

Page 18

USER’S NOTES

18

SCANTEAM 2380 Programming Menu