The text of a manual · part 1 of 3
SCANTEAM 2380 Wand Programming Menu, pages 1 to 9
Pages 1 to 9 of 26
The original document is the PDF (252 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST2380
Page 1
Welch Allyn: SCANTEAM® 2380 WAND
Programming Menu
Page 2
SCANTEAM 2380 Programming Menu
NOTES
Please Note: The programming features on each menu page are not supported in all models and software revisions of the SCANTEAM 2380. Notations are included if the feature is available only in certain models. Contact your Welch Allyn Sales Coordinator for the revision/model to fit your needs. The SAMPLE BAR CODES page (near the end of the programming menu) contains bar code symbols that you may use to verify that you have programmed your SCANTEAM 2380 correctly.
Disclaimer
Welch Allyn reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Welch Allyn to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Welch Allyn. Welch Allyn shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Welch Allyn, Incorporated. 1999 Welch Allyn, Inc. All rights reserved. Data Collection Web Addresss: http://dcd.welchallyn.com
Page 3
STATUS
SCANTEAM 2380/PM Programming Menu
CHECK
SHOW FIRMWARE REVISION LEVEL Scan the bar code below to display the revision level of the SCANTEAM 2380 firmware.
For example: After scanning the Firmware Revision Level bar code, “(C) WA93C” is output to the terminal/host device. The “C” at the end indicates the firmware is at revision level C.
Firmware Revision Level
SHOW SOFTWARE NUMBER Scan the bar code below to display the SCANTEAM 2380 software number. The resulting information will show if there is a special or custom download program resident in the scanner.
For example: After scanning the Software Number bar code, “33961001” is output to the terminal/host device. That number is the software number.
Software Number
SCANNER LABELING The drawing below shows the serial number label that is attached to the scanner cord. The top number shows the SCANTEAM 2380 model number. This may also be a special 6 digit part number (custom orders). The serial number is on the second line. The “C” after the serial number indicates that the firmware Mask revision is C.
2380/B–211DX J01 1234C
3
Page 4
USER’S NOTES
4
SCANTEAM 2380 Programming Menu
Page 5
SYSTEM
SCANTEAM 2380/PM Programming Menu
GUIDE
USE THIS PAGE As a general overview of the programming menu. The programming menu consists of two basic components as shown below. SELECTION II (RETAIL) USE THIS PAGE
BAR CODE CHART
Programming Menu
CODE
Programming Menu
USE THIS PAGE In combination with the adjoining menu pages to program the unit. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.
ROMAN NUMERALS
LETTERS
DIGITS
OTHERS
To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To enable or disable listed code selections.
scan
I selections
ENTER
UPC ID = c (HEX 63)
scan scan
DEFAULT
EAN ID = d (HEX 64) UPC & EAN Addenda Req’d. MSI ID = g (HEX 67) Plessey ID = n (HEX 6E)
variables scan scan
Version A Version D(2) Version E0 Version E1 Check Digit Xmit Number System Xmit Version E Expand 2–Digit Addenda 5–Digit Addenda
A B C D E F G H I
*Yes/No No* *Yes/No *Yes/No *Yes/No *Yes/No Yes/No* *Yes/No *Yes/No
EAN/JAN 13 EAN/JAN 8 Check Digit Xmit 2–Digit Addenda 5–Digit Addenda
A B C D E
*Yes/No *Yes/No *Yes/No *Yes/No *Yes/No
Enable
Yes/No*
Enable Minimum Length Maximum Length
A B
Yes/No* *04–Max Min–48*
Enable Minimum Length Maximum Length
A B
Yes/No* *04–Max Min–48*
A XI
II
B XII
III
C
IV
D 3 E XV
VI
4 F
XVI VII
5 G
XVII VIII
6 H
XVIII IX
EXIT
X
7 I
XIX
8 J
XX
SAMPLE MENU PAGE
EXIT 2
XIV scan
DEFAULT 1 (NO)
XIII
V
Notes: (1) * Designates DEFAULT selections. (2) UPC Version D is not supported at this time.
ESCAPE 0 (YES)
9
BAR CODE CHART
MENU PAGE Each menu page represents one section of the programming menu. Use individual menu pages in combination with the bar code chart on the back page foldout to program the decoder. USE THIS PAGE – is a summary of the programming options (parameters) of each menu page. ENTER – Each menu page has its own unique ENTER bar code; scan this bar code to activate desired menu page. DEFAULT – Most menu pages have a DEFAULT bar code which allows the user to independently default menu pages to astericked (*) values without affecting, in any way, the rest of the programming menu. Default values can be easily selected from the desired menu pages by scanning the bar code sequence ENTER, DEFAULT, EXIT. Individual defaults for a specific selection can be made by scanning ENTER, ROMAN NUMERAL, DEFAULT, EXIT. EXIT – To move from one menu page to another, scan the EXIT bar code. This bar code must be scanned to end programming selection on each menu page before beginning to program on a different menu page. SELECTIONS/VARIABLES – Lists all of the options available on each menu page. Following each option are symbols in shaded areas. These symbols correspond to bar codes on the adjoining bar code chart. NOTES – are provided to call out any unusual situations and/or refer you to necessary information or examples elsewhere in the menu or manual.
MENU PAGE FACING (Not Shown) The page facing the menu is often used to supplement or clarify the material presented on the front of each menu page. The information and examples found here are specific to the individual menu page and contain, in some cases, charts and diagrams that must be used in order to determine the correct programming sequence.
BAR CODE DATA CHART The bar codes on this chart are assigned to a ROMAN NUMERAL, DIGIT, LETTER OR YES/NO symbol. These bar codes correspond to the symbols in shaded areas on the menu pages and are scanned in various combinations to enter programming sequences to the decoder. Bar codes on this page are meaningless unless an ENTER bar code from one of the menu pages is first scanned. When an ENTER bar code is scanned, the bar code chart becomes specific to that menu page and remains so until the EXIT bar code is scanned or another menu page is selected.
ESCAPE Use this bar code to cancel current programming sequence. All parameters remain as they were. Scan ESCAPE.
5
Page 6
TERMINAL
SCANTEAM 2380 Information and Examples
SELECTION
DIRECT CONNECT ENABLE When enabled, this programming selection allows the wand scanner to replace the keyboard. The scanner will respond the the PC keyboard initialization commands upon power up. This selection is for an AT keyboard only with a terminal ID of 03.
LOW POWER When enabled, this programming selection puts the wand scanner in a low power mode. The LED will be pulsed to conserve power and will “wake up” when a transition from black to white is seen.
6
Page 7
TERMINAL
SCANTEAM 2380 Programming Menu
SELECTION
USE THIS PAGE To select the terminal type. To enable the AT Direct Connect feature. To enable the Low Power feature.
scan scan ENTER terminal selection
IBM
PC/XT PS/2 model 30 PC/AT, PS/2 50–80 PS/2 30–286
OLIVETTI scan 01 02 03
3196/97, 3476/77 3191/92, 3471/72 (102 Keyboards)
07
3196/97, 3476/77 (122 Keyboards)
08
3191/92, 3471/72 (122 Keyboards)
09
M19, M24, M28
01
M200, M240, M250, M290, M380, P500
03
TELEX
078/079/080/191
09
DEC
VT220, 320, 340 VT400 Series through V1.4
04
VT400 Series V2.0 and above (5)
AT DIRECT CONNECT
Enable (3, 4)
LOW POWER
Enable (4)
05 Yes/No* Yes/No* scan
EXIT
Notes: (1) For proper installation to selected terminal the proper 2380 “Y interface cable must be used. Cable part numbers are listed on the facing page. (2) No default parameters are programmed for this page. (3) Only for a terminal ID of 03. (4) Available for Mask C only. (5) Terminal ID of 05 not supported by standard 2380 software. Must order via special 6 digit part number. Contact your Sales Representative for ordering information.
7
Page 8
OUTPUT PARAMETERS
SCANTEAM 2380 Information and Examples
& FORMAT SELECTIONS PREAMBLE/POSTAMBLE
Preambles and Postambles are characters added by the 2380 to scanned bar code data. These characters are sent with the bar code data to the terminal. Use the Hex–ASCII table below to find the alpha–numeric code to be used for programming a particular Preamble or Postamble. NOTE: The 2380 will translate characters 00–1F (keyboard function codes) into keyboard “function keys.” The assigned translation is dependent upon the terminal being used. Refer to the 2380 Technical Manual to determine the assigned translation.
PROGRAMMING EXAMPLE To program a Carriage Return (CR) Postamble: Scan: Enter, II, A, 0, D, EXIT. NOTE: To clear Pre/Postamble Scan: Enter, I (or II), Default, and then EXIT.
HEX – ASCII CHART NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F
DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
SP ! ” # $ % & ’ ( ) * + , – . /
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ A B C D E F G H I J K L M N O
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F
P Q R S T U V W X Y Z [ \ ] ^ _
50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
‘ a b c d e f g h i j k l m n o
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F
CODE IDENTIFICATION YES – Adds a lower case letter preamble to the bar code data sent to the terminal to denote the bar code symbology scanned. This preamble will follow any preamble programmed in I. NO – Does not add lower case preamble. Lower Case Preamble Symbology Lower Case Preamble Symbology a Codabar h Code 11 b Code 3 of 9 i Code 93 c UPC j Code 128 d EAN k AMES e I 2 of 5 m Matrix 2 of 5 f 2 of 5 n Plessey g MSI
FUNCTION CODES YES – The 2380 translates characters 00–1F (keyboard function codes) that may be contained within bar code data into “function keys.” These function keys will be sent to the terminal along with the other characters in the bar code data. NO – The 2380 does not translate characters 00–1F into “function keys.” Instead, characters 00–1F are stripped from the bar code data. NOTE: Keyboard function codes that are programmed in the postamble and preamble remain active at all times.
KEYBOARD TYPE (If terminal is not listed, then no secondary type keyboard is supported.) Primary Secondary Terminal Type Type
Tertiary* Type
Quaternary Type
IBM PC, PC/XT
XT
CAPS LOCK
CTRL +
SHIFT LOCK
IBM PS/2 (50–80)
NORM
CAPS LOCK
CTRL +
SHIFT LOCK
DEC
NORM
CTRL +
* ASCII function codes (00–1F) are sent to the terminal via a ”CTRL+” sequence (i.e. ’CR’=CTRL+M)
INTERCHARACTER DELAY INTERFUNCTION DELAY INTERMESSAGE DELAY Intercharacter Delay – When enabled, an intercharacter delay of between 01 and 99 (x5) milliseconds can be programmed. Incoming messages may not have an intercharacter delay greater than (10 byte time at the programmed baud rate. Interfunction Delay – The time delay between ”function key” characters output by the 2380. EXAMPLE: 2380 programmed as follows: Intercharacter delay=10ms Interfunction delay=50ms Postamble=field exit and transmit When a bar code symbol containing the characters 123 is scanned, the 2380 will output to the terminal as follows: 1 10ms 2 3 Field Exit 10ms 10ms 50ms Transmit delay delay delay delay Intermessage Delay – The time delay between bar code data output by the 2380. Beeper – This programming selection provides control of the Beeper. When “Beep on Reset” is enabled, the Beeper will beep each time the system is reset. If “Beep on Good Read” is enabled, the Beeper will beep following a scan when the data has been accepted by the Host. Append Buffer – Controls state of Append Buffer. This buffer must be enabled if Code 3 of 9 symbology with Append Option has been selected.
8
Page 9
OUTPUT PARAMETERS
& FORMAT SELECTION
SCANTEAM 2380 Programming Menu scan
USE THIS PAGE To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To add preambles and/or postambles to the bar code. To select function transmit enable. To select keyboard type. To set intercharacter, interfunction, and intermessage delays to specific values. To control scanning indicators or enable function records feature. To enable the Append Buffer when Code 3 of 9 with append option is enabled.
selections scan variables scan
Code ID Other ASCII
A B A scan
ENTER
PREAMBLE (3) (up to 5 chars max)
I scan
POSTAMBLE (4) (up to 5 chars max)
II
ASCII values
FUNCTION XMIT
III
Enable
*Yes/No
KEYBOARD TYPE
IV
Primary
01*
Secondary
02
DEFAULT scan
00–7F None* 00–7F None*
Tertiary
03
Quaternary
04
V x5msecs
*00–99
VI x5msecs
*00–99 *00–99
INTERCHARACTER DELAY INTERFUNCTION DELAY INTERMESSAGE DELAY BEEPER (5, 6)
VII x5msecs
VIII
Beep on Reset
A
Beep on Good Read (7)
B
APPEND BUFFER
IX
*Yes/No
FUNCTION RECORDS (8)
X
*Yes/No
*Yes/No *Yes/No
Notes: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples. (3) To delete preambles Scan I then either another selection (roman numeral) or Exit. (4) To delete postambles Scan II then either another selection (roman numeral) or Exit. (5) Default is NO if Beep PC is enabled. (6) This programming feature has been changed for Mask C. Refer to the cable labeling to determine which firmware you have. (7) This programming feature is not supported in all models/software revisions. (8) Available for Mask C only.
EXIT
9