The text of a manual · part 26 of 26
Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser: Default Chart
Pages 219 to 232 of 232, from Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST2070, HHP ST3870 and HHP ST5770
Page 219
12 Default Chart The following chart lists the factory default settings (indicated by an asterisk (*) on the programming pages). Parameter
Default Setting
Page
United States
2-8
Country Code Selections Keyboard Country
Keyboard & Delays Selection Keyboard Style
Regular
2-9
Control + ASCII Mode Off
2-10
Turbo Mode Off
2-10
Numeric Keypad Mode Off
2-10
Auto Direct Connect Off
2-11
Intercharacter Delay
00 (x5mS)
2-11
Interfunction Delay
00 (x5mS)
2-11
Intermessage Delay
00 (x5mS)
2-11
Keyboard Style Modifiers
Output Delays
Wand Emulation Selections Transmission Rate
25 ips
2-12
Output Polarity
Black High
2-13
Base Low Power Mode
Off
2-14
Battery Conservation Mode
No Timeout
2-15
Baud Rate
38400
3-2
Parity
None
3-3
Power Settings
Host Port Communications
12 - 1
Page 220
Parameter
Default Setting
Page
Word Length Data Bits
8
3-3
Word Length Stop Bits
1
3-4
Hardware Flow Control
Off
3-7
Serial Wedge Output
None (RS-232)
3-5
Host ACK
Off
3-7
Decode Beep
Off
3-10
Auxiliary Port Communications Baud Rate
38400
3-11
Parity
None
3-12
Word Length Data Bits
8
3-12
Word Length Stop Bits
1
3-13
Hardware Flow Control
Off
3-13
Protocol
Record
3-16
SOR (Start of Record)
00 (NUL)
3-17
EOR (End of Record)
0D (CR)
3-17
SOB (Start of Block)
00 (NUL)
3-17
EOB (End of Block)
04 (EOT)
3-17
Aux Prefix (Incoming Data)
None
3-18
Aux Suffix (Incoming Data)
None
3-18
Aux Prefix (Outgoing Data)
None
3-18
Aux Suffix (Outgoing Data)
CR
3-18
Aux Prefix (On/Off)
On
3-22
Aux Suffix (On/Off)
On
3-22
Data Character
Aux Prefix/Suffix
12 - 2
Page 221
Parameter
Default Setting
Page
Aux Port I.D. Transmit
Off
3-22
On, But Not Required
3-28
Aux Data Formatter Aux Data Formatter
Output Selections (User Feedback) Application Work Group
Group 0
5-11
Font Size Preference
VeryClear Small
5-9
Display Language Preference
English
5-10
Beeper Volume
High
5-11
Beeper Pitch
Medium
5-11
Scanner Voting
Voting Normal
5-12
Laser Marker Beam
Off
5-13
AIM I.D. Prefix
Off
5-13
Code I.D. Prefix
Off
5-14
Prefix
None
5-18
Suffix
CR
5-18
Prefix On/Off
On
5-20
Suffix On/Off
On
5-21
Data Formatter
On
5-26
Require Data Format
Not Required
5-27
Decode Beep
Off
5-28
On
6-2
Prefix/Suffix Selections
Data Formatter Selections
Codabar Selections Codabar
12 - 3
Page 222
Parameter
Default Setting
Page
Start/Stop Characters
Don’t Transmit
6-2
Codabar Message Length
Min = 4, Max = 60
6-3
Check Character
No Check Character Encoded
6-4
Concatenation
Allowed, But Not Required
6-4
Code 39
On
6-6
Start/Stop Characters
Don’t Transmit
6-6
Code 39 Message Length
Min = 0, Max = 48
6-7
Check Character
No Check Character Encoded
6-8
Full ASCII
On
6-9
Append
Off
6-10
Code 93
On
6-11
Code 93 Message Length
Min = 0, Max = 64
6-12
Interleaved 2 of 5
On
6-13
Interleaved 2 of 5 Message Length
Min = 4, Max = 80
6-14
Check Digit
No Check Digit Encoded
6-15
Code 2 of 5
On
6-16
Code 2 of 5 Message Length
Min = 4, Max = 80
6-17
Matrix 2 of 5
On
6-18
Matrix 2 of 5 Message Length
Min = 4, Max = 80
6-19
Code 39 Selection
Code 93 Selection
Interleaved 2 of 5 Selection
Code 2 of 5 Selection
Matrix 2 of 5 Selection
12 - 4
Page 223
Parameter
Default Setting
Page
Code 11
On
6-20
Check Digits Required
2 Check Digits
6-20
Code 11 Message Length
Min = 4, Max = 80
6-21
Code 128
On
6-22
Code 128 Message Length
Min = 0, Max = 80
6-23
<GS> Substitution
On
6-24
ISBT128
Off
6-24
Telepen
On
6-25
Telepen Message Length
Min = 1, Max = 60
6-26
Telepen Output
Numeric Only
6-26
Code 11 Selection
Code 128 Selection
Telepen Selection
China Post Code Selection (IT3870/IT3875 only) China Post Code
Off
6-27
China Post Code Message Length
Min = 4, Max = 80
6-28
RSS-14 Selection (IT3870/IT3875 only) RSS-14
Off
6-29
RSS Limited
Off
6-29
RSS Expanded
Off
6-29
RSS Message Length
Min = 4, Max = 74
6-30
PDF417 Selection (IT3870PDF/IT3875PDF only) PDF417
On
6-31
PDF417 Message Length
Min = 1, Max = 2750
6-32
12 - 5
Page 224
Parameter
Default Setting
Page
Show GLI Blocks
Don’t Show GLI Blocks
6-33
Macro PDF417
Buffer
6-34
Show Macro Control Blocks
Don’t Show Control Blocks
6-34
Scan Diagnostics
Off
6-35
PDF Learn Mode
Off
6-35
MicroPDF417 Selection (IT3870PDF/IT3875PDF only) MicroPDF417
Off
6-36
MicroPDF417 Message Length
Min = 1, Max = 366
6-37
EAN•UCC Composite Symbology Selection (IT3870PDF/ IT3875PDF only) EAN•UCC Composite Symbology
Off
6-38
Enable UPC/EAN Version
Off
6-38
EAN•UCC Composite Symbology Message Length
Min = 1, Max = 2400
6-39
EAN / JAN 8
On
6-40
Check Digit
Transmit
6-41
EAN / JAN 13
On
6-41
Check Digit
Transmit
6-41
ISBN
Off
6-41
UPC A
On
6-42
Check Digit
Transmit
6-43
Number System
Transmit
6-43
EAN / JAN 8 Selection
EAN / JAN 13 Selection
UPC A Selection
12 - 6
Page 225
Parameter
Default Setting
Page
UPC E0
On
6-44
Check Digit
Transmit
6-44
Number System
Transmit
6-44
Version E Expand
Don’t Expand
6-45
Off
6-45
UPC E0 Selection
UPC E1 Selection UPC E1
EAN/UPC Addenda Selection EAN/UPC Addenda
Don’t Require
6-46
EAN Two Digit Addenda
Off
6-46
EAN Five Digit Addenda
Off
6-46
UPC Two Digit Addenda
Off
6-47
UPC Five DIgit Addenda
Off
6-47
12 - 7
Page 226
12 - 8
Page 227
Page 228
Sample Symbols UPC A
0 123456 7890
Interleaved 2 of 5
Code 128
1234567890
Code 128
Code 39
BC321
Code 11 with 2 Check Characters
0123456789
EAN 13
9 780330 290951
Codabar
A13579B
Page 229
Sample Symbols PDF417
MicroPDF417
PDF417 Test Message
MicroPDF417 Test Message
Matrix 2 of 5
6543210
Code 93
Code 2 of 5
123456-9$
RSS-14 123456
(01)00123456789012
EAN•UCC Composite Symbology with RSS Limited
(01)12345678901231(10)123456789(11)001205(3202)001234
Page 230
Programming Chart This programming chart contains alphanumeric bar codes used for setting additional programming options, such as the digits representing Symbology Message Length. Scan the programming selection bar code first, and then scan the bar code(s) representing the option you want to set.
0
1
2
3
4
5
6
7
8
9
Page 231
Programming Chart
TUL A MAT B MA Cc MN D MTN
E
F
Discard Current Changes
Save
Page 232
HiR
Upgrade your image.
700 Visions Drive P.O. Box 208 Skaneateles Falls, NY 13153-0208