Page 209

10 Maintenance and Troubleshooting Maintenance !

Warning:

Do not submerge the cordless scanner or the cordless base in water. Their housings are not water-tight. Do not use abrasive wipers or tissues on the scan window: abrasive wipers may scratch the window. Never use solvents (alcohol or acetone) on the housings or the window: solvents may damage the finish or the window. Do not open the cordless scanner or the cordless base. There are no serviceable parts inside. The cordless scanning system provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation:

Cleaning the Scan Window of the Cordless Scanner Scanning performance may degrade if the cordless scanner’s scan window is not clean. If the window is visibly dirty, or if the scanner isn’t scanning well, clean the scan window with a soft cloth or facial tissue dampened with water (or a mild detergent-water solution). If a detergent solution is used, rinse with a clean tissue dampened with water only. The cordless scanner and base housings may also be cleaned the same way.

Inspecting Cords and Connectors Inspect the cordless base’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with operation. Contact your Hand Held Products distributor for information about cable replacement. Cable replacement instructions are on page 10-2.

Examining the Cordless Scanner and Cordless Base Housings Routinely examine the cordless scanner and cordless base housings for signs of damage. A damaged housing may cause the internal components to move and may result in a malfunctioning unit.

10 - 1

Page 210

Care and Handling of the Charge Pack Proper handling of the batteries while recharging extends the useful life of the batteries. New charge packs are shipped uncharged. In order to break in the new battery, we suggest that you fully charge and discharge the packs two times so they can be conditioned for full capacity and longer life. If the charge pack is left plugged in for extended periods of time (for instance, several weeks) the contacts between the prongs may become dirty, causing charging problems. Clean the prongs with a cotton swab and rubbing alcohol to remove any accumulation of dirt.

Replacing the Interface Cable The standard host interface cable is attached to the cordless base with a 15-pin D-type receptacle connector. Tighten the holding screws to properly seat the interface connector. The cable is designed to be field replaceable. Auxiliary Port cables use a 10-position modular plug. To remove the Aux Port cable, depress the dimple located on the bottom of the base unit underneath the Aux Port and pull the cable from the unit.

Note: Order replacement cables from Hand Held Products or from an authorized distributor. When ordering a replacement cable, specify the cable part number of the original interface cable.

Recharging and Replacing the Cordless Scanner’s Charge Pack To maintain the maximum charge capacity, batteries should be allowed to fully discharge prior to charging. It is recommended that you establish a process where a battery is used until it is fully discharged and fully charged before its next use. See "Charging Your Charge Pack" on page 1-5 for instructions on recharging and replacing the cordless scanner charge pack.

To Reset Factory Settings If you are unsure of the programming options that have been set up in your cordless system, or you’ve changed some options and now want the factory settings restored, refer to “Reset Factory Settings” on page 2-17 and scan the appropriate Factory Default Settings bar code.

10 - 2

Page 211

Troubleshooting The cordless system automatically performs self-tests whenever you turn it on. If your cordless scanner or cordless base is not functioning properly, review the following Troubleshooting Guide to isolate the problem.

Troubleshooting Guide Is the power on? Is the Scanner’s red illuminated beam on? If the red scan beam on the cordless scanner isn’t illuminated, check that: 1. the charge pack is connected properly to the cordless scanner. 2. the charge pack is not low on power (check the low battery LED).

Is the cordless system having trouble reading your bar codes? If the cordless system isn’t reading bar codes well, check that: 1. the bar codes aren’t smeared, rough, scratched, or exhibiting voids. 2. the bar codes aren’t coated with frost or water droplets on the surface. 3. the bar code symbology is enabled (see Chapter 6, Symbology Menu). 4. the cordless scanner window is clean.

Is the bar code displayed but not “entered”? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example). You need to program a suffix. Programming a suffix enables the cordless system to output the scanned bar code plus the key you need (such as a “CR” carriage return) to enter the bar code into your application. (See Suffix Selection in Chapter 5, Application Work Group Menu.)

Does the cordless system read your bar code incorrectly? If the cordless system reads a bar code (one beep for a good read), but the bar code is not displayed correctly on the host screen: 1. The cordless system may not be programmed for the appropriate terminal interface. Example: You scan “12345 ” and the host displays “@es%”. Reprogram the cordless system with the correct “Plug and Play” or Terminal Selection bar code (see Chapter 1).

10 - 3

Page 212

2. The cordless system may not be programmed to output your bar code properly. Example: You scan “12345 ” and the host displays “A12345B ”. Reprogram the cordless system with the proper Symbology selections (see Chapter 5, Symbology Menu).

The cordless system won’t read your bar code at all? If the cordless system will not read your bar code: 1. Try scanning the Sample Bar Codes (found near the back of this manual). If the cordless system reads the Sample Bar Codes, check that your bar code is readable. (See “Is the cordless system having trouble reading your bar codes?” on page 10-3.) Verify that your bar code symbology is enabled. (See Chapter 5, Symbology Menu.) If the cordless system does not read the Sample Bar Codes either, continue to #2, below. 2. If the cordless system won’t read the Sample Bar Codes either: Verify that the bar code symbologies are enabled. (Chapter 5, Symbology Menu.) Scan the “Default All...” bar code on each symbology menu page in Chapter 5, Symbology Menu to enable most symbologies.

10 - 4