Page 83
Auxiliary Port Input Communications Aux Prefix Selection
Add Aux Prefix1
Default Aux Prefix (none)
Clear All Aux Prefixes
Aux Suffix Selection
Add Aux Suffix1
Default Aux Suffix (CR)
Clear All Aux Suffixes 1. Scan 7 and 2 and then one or more two-digit numbers and Save after scanning this programming bar code. Refer to the Programming Chart (inside back cover).
Exit Selection for Aux Prefix / Suffix
Save
Discard
3 - 21
Page 84
Auxiliary Port Input Communications Aux Prefix On/Off The following selections allow you to turn on and off the Aux Prefix and Suffix formatting. These codes are used when you want to toggle between turning on and off the prefix and/or suffix formatting.
*On
Off
Aux Suffix On/Off
*On
Off
Aux Port I.D. Transmit Selection This will attach the Aux Port identifier (which is the letter “r”) to the incoming data at the Auxiliary Port and will send it along with the data to the host device.
On
*Off
3 - 22
Page 85
Auxiliary Port Input Communications Aux Data Format Editor Selections The Aux Data Format Editor selections are used to edit incoming data to the aux port. For example, you can use the Aux Data Format Editor to insert characters at certain points in bar code data as it is scanned. It is not necessary to use the Aux Data Format Editor. A set of defaults for the aux data format is already programmed in the base. The selections in the following pages are used only if you wish to alter the default settings. Default Aux Data Format setting = none. If you have changed aux data format settings, and wish to clear all formats and return to the defaults, scan the Default Aux Data Format code. To Add an Aux Data Format Step 1. Scan the Enter Aux Data Format symbol (page 3-27). Step 2. Primary/Alternate Format Determine if this will be your primary aux data format, or one of 3 alternate formats. (Alternate formats allow you “single shot” capability to scan one bar code using a different aux data format. After the one bar code has been read, the scanner reverts to the primary aux data format. See page 3-28.) If you are programming the primary format, scan 0. If you are programming an alternate format, scan 1, 2, or 3, depending on the alternate format you are programming. Step 3. Terminal Type Refer to the Supported Terminals Chart (page 2-6) and locate the Terminal ID number for your PC. Scan 3 numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an IBM AT.
Note: To apply a format to all terminal types, a universal code of 099 is used. Step 4. Code I.D. Scan 7 then 2 from the Programming Chart. (This is the hex value for “r,” the aux port I.D.) Step 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the 4 digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to the Format Editor Commands (page 3-25). Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format. Step 7. Scan Save to save your entries.
3 - 23
Page 86
Auxiliary Port Input Communications Other Programming Selections • Clear One Aux Data Format This deletes one aux data format for one symbology. If you are clearing the primary aux format, scan 0. If you are clearing an alternate format, scan 1, 2, or 3, depending on the alternate format you are clearing. Scan the Terminal Type (refer to the Supported Terminals Chart on page 2-6), then 7, 2 (for the aux port I.D.), and the length of the format you want to delete. That length aux data format for that symbology is deleted and all other formats are unaffected. • Save This exits, saving any Aux Data Format changes. • Discard This exits without saving any Aux Data Format changes.
Aux Data Formatter Example Five digit data is sent to the Auxiliary Port, however the host system can only accept eight digit data. Three zeroes must be added to the beginning of the Aux Port data. Received Must send 12345 00012345 Refer to the Aux Format Editor Commands on page 3-25 to format the following example. The programming bar codes on page 3-27 and the alphanumeric bar codes on the inside back cover are used to program the aux data formatter. • Scan the Enter Aux Data Format bar code (page 3-27). • Scan 0 (primary) or 1 or 2 or 3 (for alternates). • Scan 0 9 9 (all terminal types). • Scan 7 2 (the hex value for the aux port). • Scan 0 0 0 5 (the data length).
3 - 24
Page 87
Auxiliary Port Input Communications The Aux Data Editor Commands are: • Scan F 4 (see page 3-25 for a description). • Scan 3 0 (hex value for 0). • Scan 0 3 (indicating the 0 should be sent 3 times). • Scan F 1 to send the data, then 0 0 (the hex value for NUL). • Scan Save to end the Aux Data Formatting.
Aux Format Editor Commands Send Commands F1 Send all characters followed by “xx” key or function code, starting from current cursor position. Syntax = F1xx (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.) F2 Send “nn” characters followed by “xx” key or function code, starting from current cursor position. Syntax = F2nnxx (nn stands for the numeric value (00-99) for the number of characters and xx stands for the hex value for an ASCII code. See Hex to ASCII Conversion chart, page 3-20.) F3 Send up to but not including “ss” character (Search and Send) starting from current cursor position, leaving cursor pointing to “ss” character followed by “xx” key or function code. Syntax = F3ssxx (ss and xx both stand for the hex values for ASCII codes, see Hex to ASCII Conversion chart, page 320.) F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20, and nn is the numeric value (00-99) for the number of times it should be sent.) E9 Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (nn is the numeric value (00-99) for the number of characters that will not be sent at the end of the message.)
Move Commands F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved ahead.) F6 Move the cursor back “nn” characters from current cursor position. Syntax = F6nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved back.) F7 Move the cursor to the beginning of the data string. Syntax = F7. EA Move the cursor to the end of the data string. Syntax = EA.
Search Commands F8 Search ahead for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F8xx (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.)
3 - 25
Page 88
Auxiliary Port Input Communications F9 Search back for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F9xx (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.) E6 Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. Syntax = E6xx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 3-20.) E7 Search back for the last instance of “xx” character from the current cursor position, then increment cursor. Syntax = E7xx (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.)
Miscellaneous Commands FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number suppress characters in the list and xxyy .. zz is the list of characters to be suppressed. (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.) FC Disable suppress filter and clear all suppressed characters. Syntax = FC. E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. E5 Terminates character replacement. Syntax = E5. FE Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see Hex to ASCII Conversion chart, page 3-20.) EC Check to make sure there is a numeric character at the current cursor position. If character is not numeric, format is aborted. Syntax = EC. ED Check to make sure there is a non-numeric character at the current cursor position. If character is numeric, format is aborted. Syntax = ED. EF Inserts a delay of up to 196,605 milliseconds (in multiples of 5). Syntax = EFnnnn where nnnn is a 4-digit hex format count of the number 5 ms delays, up to FFFF.
3 - 26
Page 89
Auxiliary Port Input Communications Aux Data Format Editor See through page 3-23 through page 3-26 for a description of Aux Data Format selections and commands.
Enter Aux Format
Default Aux Data Format
Clear One Aux Data Format
Clear All Aux Data Formats
Save Current Changes
Discard Current Changes
3 - 27
Page 90
Aux Data Formatter When Aux Data Formatter is turned off, the data coming into the aux port is output to the host as received (including prefixes and suffixes). When Aux Data Formatter is required, all incoming data must conform to an edited format or the base does not transmit the input data to the host device. If this occurs, the data is discarded. Default = Aux Data Formatter On, but Not Required.
*Aux Data Formatter On, but Not Required Aux Data Formatter Off
*Aux Data Formatter On and Required
Alternate Aux Data Formats Alternate formats allow you “single shot” capability to edit incoming data using a different aux data format than your primary aux format. When aux data formats are programmed (see page 3-18), you must input whether you are programming the primary aux format, or an alternate format numbered 1, 2, or 3. An alternate aux format is initiated by scanning one of the 3 alternate aux format bar codes below. The base will edit the incoming data, formatting the data with the selected alternate aux format, then revert immediately to the primary aux format.
Alternate Aux Data Format 1
Alternate Aux Data Format 2
Alternate Aux Data Format 3
3 - 28