Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 14

SCANTEAM 2010 Wedge Keyboard Wedge/Commercial Decoder User's Guide, pages 61 to 70

Pages 61 to 70 of 134

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST2010

Page 61

✱ Default All RS-232 Port 1 Settings ✱

CTS Check Selection

✱

Baud Rate Selection

✱

SCANTEAM 2010 User’s Guide

4–3

Page 62

The text of this page cannot be shown here; see it in the PDF.

Page 63

Word Length Data Bits Selection

-

✱ -

Word Length Stop Bits Selection

- -

✱ - -

Parity Selection

-

✱

SCANTEAM 2010 User’s Guide

4–5

Page 64 read from a scan by OCR; it may hold reading errors

RS-232D Port 1 (Auxiliary Data Input)

Protocol

This programming selection allows you to program the decoder for whichever protocol your application requires. The protocol is a set of rules concerning the exchange of data between serially communicating devices. The decoder supports Record, Burst, Ack / Nak Record, and Ack / Nak Burst protocols when receiving data from an RS-232 device. Default = Record.

When Record Protocol is enabled, the decoder accepts a data record of variable length up to a maximum of 253 characters including preamble, postamble, and a one character delimiter. The incoming data record must end with an End of Record (EOR) character that matches the EOR character programmed into the decoder. If a Start of Record character is programmed, the decoder won't accept data until that SOR is detected.

When Burst Protocol is enabled, the decoder accepts one or more data records of variable lengths. Each data record must end with the EOR character programmed into the decoder. The decoder stops accepting data when an End of Block (EOB) character is received. Start of Block (SOB) and SOR characters may be programmed.

The decoder can be programmed to receive data in one of two ACK/NAK protocols, Ack / Nak Record mode or Ack / Nak Burst mode. Both are similar to the protocols described above (record = one data record, burst = one or more data records). The difference is that, in Ack / Nak mode, the decoder issues an ACK (acknowledge) when it receives a data record successfully. If an error is encountered in the data record(s), the decoder issues a NAK (not acknowledge) to the RS-232D transmitting device.

Data Characters

This programming selection allows you to select the serial output data characters that may be required by the RS-232D protocol.

The Start of Record Character (SOR) is one of the characters 01h - 7Fh that indicates the start of an RS-232D data record. Default SOR character = 00.

The End of Record Character (EOR) is one of the characters 01h - 7Fh that marks the end of an RS-232D data record. Default EOR character = OD (which is CR, a carriage return).

The Start of Block Character (SOB) is one of the characters 01h - 7Fh that indicates the start of a block of data within an RS-232D data block. Default SOB character = 00.

The End of Block Character (EOB) is one of the characters 01h - 7Fh that indicates the end of a block of data within an RS-232D data block. Default EOB character= 04 (which is EOT, End of Text).

Note: SOB, EOB, SOR, and EOR characters are not considered data, and, therefore, are not sent to the terminal. Refer to the Hex ASCII chart (page 3-16) for the two-digit Hex representation of the ASCII data character you wish to program.

4-6 SCANTEAM 2010 User’s Guide

Page 65 read from a scan by OCR; it may hold reading errors

RS-232D Port 1 (Auxiliary Data Input)

Protocol Selection

* Record Burst

Ack / Nak Record Ack / Nak Burst

Data Character Selection +

Start of Record End of Record

Start of Block End of Block

+ A two-digit number is required after scanning this programming bar code. Please scan your selection on the Programming Chart (inside back cover).

SCANTEAM 2010 User’s Guide 4-7

Page 66

Default All Serial Communications Selections $#

CTS Check

Default = Disable.

Baud Rate

-# # " $ " Default = 9600 bps.

A pinout chart is shown in Section 8, Product Specifications and Pinouts.

4–8

SCANTEAM 2010 User’s Guide

Page 67

✱ Default All RS-232 Port 2 Settings ✱

CTS Check Selection

✱

Baud Rate Selection

✱

SCANTEAM 2010 User’s Guide

4–9

Page 68

The text of this page cannot be shown here; see it in the PDF.

Page 69

Word Length Data Bits Selection

-

✱ -

Word Length Stop Bits Selection

- -

✱ - -

Parity Selection

-

✱

SCANTEAM 2010 User’s Guide

4–11

Page 70 read from a scan by OCR; it may hold reading errors

Notes...

Notes: 4p

The space below may be used for notes. ...

4-12 SCANTEAM 2010 User’s Guide