The text of a manual · part 6 of 14

SCANTEAM 2010 Wedge Keyboard Wedge/Commercial Decoder User's Guide, pages 51 to 60

Pages 51 to 60 of 134

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST2010

Page 51 read from a scan by OCR; it may hold reading errors

Country Code Selections

Foreign Keyboard Selection

MI * United States WIN I Belgium Denmark WINN I Finland Norway ANAM ANAM Sweden France WINCH WN Germany, Austria Italy WN WINN

Switzerland

United Kingdom

SCANTEAM 2010 User’s Guide

Page 52

The text of this page cannot be shown here; see it in the PDF.

Page 53 read from a scan by OCR; it may hold reading errors

Keyboard Selections

Keyboard Style Selection

* Style A, Primary Style B, Secondary

Style C, Tertiary Style D, Quaternary

Style F Direct Connect

Enable * Disable

Style G, Auto-Caps Detect

Style H Num-Pad Mode

Enable * Disable

Style | Turbo Mode

Enable * Disable

SCANTEAM 2010 User’s Guide 3-21

Page 54 read from a scan by OCR; it may hold reading errors

Data Formatter Selections

Status Check

Scan the Show Formats bar code to transmit the existing Data Format Editor formats. One format per line will be printed out.

Data Formatter

When data formatter is off, the bar code data will be output to the host as scanned (including preambles and postambles). When data formatter is on, if the input data matches an edited format, the decoder will transmit the input data to the host device in the programmed format. Default = On.

Require Data Format?

When data format is required, all input data must conform to an edited format or the decoder will triple beep and will not transmit the input data to the host device. When data format is not required, any input data matching an edited format will be transmitted to the host device in the programmed format. Default = Don’t Require.

Data Format Editor

This programming selection provides editing of all input (scanned) data. All Industrial and Retail symbologies can be formatted. You may scan the Clear ... Data Format bar code if you are sure you want to delete one or all formats.

To make Data Format Editor selections, you’ll need to know the terminal type, code |.D., code length, and editor commands your application requires. Use the Alpha - numeric bar codes (page 3 - 25) to scan these options. For Hex values of

ASCII characters, refer to the Hex to ASCII Conversion Chart on page 3-5.

Use the Data Format Editor by following the steps below: @ Scan the Enter Data Format bar code to start Format Editor selection.

@ Terminal Type Scan two bar codes that represent the terminal type (00-997, page 3-25). (See Section 2, pages 2 - 10 and 2-12, for terminal |.D. list.)

® Code I.D. Refer to the Symbology chart (page 3 - 5), then scan two bar codes from the “Hex Value” column that represent the Code I.D. of the symbology you want formatted. (“All Symbologies”, hex value 99, is not supported by Data Formatter.)

® Length Scan two bar codes representing the bar code length you require (00-997). Be sure to include all spaces in the bar code length.

@® Editor Command Sequences Refer to the Format Editor Commands chart (page 3-24). Scan two bar codes that represent the command you need.

@_ End Format Scan the End Data Format to end Format Editor selection.

+ 99 is the Universal number, indicating all terminals and all code lengths.

3-22 SCANTEAM 2010 User’s Guide

Page 55

Status Check

Data Formatter

✱

Require Data Format?

✱

Data Format Editor

SCANTEAM 2010 User’s Guide

3–23

Page 56 read from a scan by OCR; it may hold reading errors

Data Formatier Selections

Format Editor Commands C hart

Send Commands

F1

F2

F3

F4

Send all characters followed by “XX” key or function code, starting from current cursor position. Syntax = F1XX (XX = HEX ASCII character or function code 0OO - FE HEX).

Send “NN” characters followed by “XX” key or function code, starting from current cursor position. Syntax = F2NNXX (NN = number of characters OO - 99 DEC, XX = HEX ASCII character or function code 0OO - EF HEX).

Send up to but not including “SS” character (Search and Send) starting from current cursor position, leaving cursor pointing to “SS” character followed by “XX” key or function code. Syntax = F3SSXX (SS = HEX ASCII Character 0O - 7F HEX, XX = HEX ASCII character O0O - 7F HEX).

Send “XX” character “NN” times (Insert) leaving cursor in current cursor position. Syntax = F4XXNN_ (XX = HEX ASCII character 0O - 7F HEX, NN = number of characters 00O - 99 DEC).

Move Commands

F5

F6

F7

Move cursor ahead “NN” characters from current cursor position. Syntax = F5NN (NN = number of characters 00-99 DEC).

Move cursor back “NN” characters from current cursor position. Syntax = F6NN (NN = number of characters 00-99 DEC).

Move cursor to the beginning of the data string. Syntax = F7.

Search Commands

F8

FQ

Search ahead for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F8XX (XX = HEX ASCII character 00- - 7F).

Search back for “XX” character from current cursor position, leaving cursor pointing to “XX” character. Syntax = F9XX (XX = HEX ASCII character 00 - 7F).

Misc ellaneous Commands

FA

FB

FC

FE

EC

ED

EE

Leading zero suppress on. Suppress leading zeroes from current cursor position until first non - zero character. Syntax = FA.

Suppress “XX” character(s) (up to three) starting from current cursor position until suppress disable command “FC” or end of format. Syntax = FBXXFB, FBXXXXFB, FBXXXXXXFB (XX = ASCII character 00 - 7F).

Disable suppress filter and clear all suppressed characters. Syntax = FC.

Compare character in current cursor position to the character “XX.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FEXX (XX = HEX ASCII character 00, 7F).

Check for numeric character at current cursor position. If true, then continue format. If false, then no format. Syntax = EC.

Check for non-numeric character at current cursor position. If true, then continue format. If false, then no format. Syntax = ED.

Leading space suppress on. Suppress leading spaces from current cursor position until first non - space character. Syntax = EE.

3-24 SCANTEAM 2010 User’s Guide

Page 57 read from a scan by OCR; it may hold reading errors

Data Formatter Selections

Hl Hil 0 1 Hil Hl 2 3 Hii HiIl 4 5 Hil Hil 6 7 MMI wiih 8 9 Il tii A B MMI II Cc D

E F

SCANTEAM 2010 User’s Guide

3-25

Page 58 read from a scan by OCR; it may hold reading errors

Data Formatter Selections

Data Formatter Example

You are using an IBM PC AT and are scanning a UPC A bar code with a five digit addenda (shown below). The bar code has a total of 18 characters, including the number system, the check digits, and a space between the main bar code data and the addenda bar code data.

UPC A with 5 digit addenda

5 67890 5

For your application, you don’t want the space between the main bar code data and the addenda bar code data transmitted. You also want the bar code data followed by a carriage return (CR).

Using the programming bar codes on pages 3-23 and 3-25, and referring to the Format Editor Commands Chart on page 3 - 24; scan the following to format the bar code data for your application:

= Scan the Enter Data Format bar code (page 3-23).

= Scan the 03 bar codes on Data Formatter Selections (page 3 - 25) for PC AT Terminal Type.

= Scan the 63 bar codes on Data Formatter Selections (page 3-25), the Hex value for UPC symbology.

= Scan the 18 bar codes on Data Formatter Selections (page 3 - 25) for the bar code length.

(The following are the Editor Command Sequences:)

= Scan the FB (suppress characters command) bar codes on Data Formatter Selections (page 3 - 25), scan 20 (the Hex value for a space), and then scan FB to frame (complete) the command.

= Scan the F7 bar codes on Data Formatter Selections (page 3 - 25) to move the cursor back to the beginning of the bar code data.

= Scan the F1 and OD bar codes on Data Formatter Selections (page 3-25) to send all the characters followed by a carriage return (CR= OD in Hex value).

= Scan the End Data Format bar code on Data Formatter Selections (page 3 - 23) to end Format Editor selection.

+ The bar code length includes all spaces.

3-26 SCANTEAM 2010 User’s Guide

Page 59

The text of this page cannot be shown here; see it in the PDF.

Page 60

Default All Serial Communications Selections $#

CTS Check

Default = Disable.

Baud Rate

-# # " $ " Default = 2400 bps.

-

A pinout chart is shown in Section 8, Product Specifications and Pinouts.

4–2

SCANTEAM 2010 User’s Guide