Page 101
Type
UCC/EAN-128
Display Message
Printout Message
Suffix
Suffix
VariCon
Variable Count
Volume
Volume
Width
Width
Area
Area
BAD Appl.ID
BAD Appli.ID
BAD Data Chk
BAD Data Checksum
BAD Start CD
BAD Start Code
Batch #
Batch #
Bill To
Bill To
Buy From
Buy From
Cell.ESN
Cellular ESN
Depth
Depth
EAN SCS
EAN SCS
FreeText
Free Text
GrossVol
Gross Volume
GrossWgt
Gross Weight
HIBCC AS
HIBCC Alt Sec
Internal
Internal
Length
Length
LONG Field
LONG Field
Lot #
Lot #
Max Date
Max Durable Date
Min Date
Min Durable Date
Multiple
Multiple
Net Wgt.
Net Weight
P.O. #
P.O.#
Pkg Date
Package Date
Prod Var
Product Variant
Quick Check® 600/800 Series User’s Guide
9-9
Page 102
Type
9 - 10
Display Message
Printout Message
ProdDate
Production Date
Quantity
Quantity
RollProd
Roll Product
Serial#
Serial #
Ship To
Ship To
SHORT Field
SHORT Field
Symbol LONG!
Symbol Too Long
UCC Serl
UCC Serial SCS
SHORT Field
SHORT Field
Symbol LONG!
Symbol Too Long
UCC Serl
UCC Serial SCS
Volume
Volume
Width
Width
Quick Check® 600/800 Series User’s Guide
Page 103
Quick Check® 600/800 Series User’s Guide tum on unit
¥
Quick
Check
-600-
OxXnm, XXmil Wand
If Printer If Printer is " Available Available J
PRINT BUFFER XX% Full XXXX Scans *Continue * Clear
NO PRINTER ATTACHED] NO PRINTER ATTACHED * Continue w/Auto Star| off on
Flow Charts
XX % Full XXXX Scans XX % Full XXXX Scans *Continue * Clear * Continue w/AutoStor PRINT BUFFER
* Continue_w/Auto Stor *Clear _* Change XX% Full _ any selection any selection [Press XXXX Scans/Prfls == Db, *Cont*Prnt*Clr ~~
Owe
¥ &t Quick | Press SELECT | ° Print Results---- Highlight & press Low Battery, or -600- ” | = Reflectometer_- rd
Recalibrate, or . an Application name, or * Change Settings--
XXX nm, XX mil Wand or DATABASE see page 2 see page 3 see page 2
10-1
Page 104
10-2
Quick Check® 600/800 Series User’s Guide
If Ext. Acc.
TYP: 200000000000000 EXTENDED Accuracy XX
Scans to Go, >
Acc. satisfied
Scan Symbo!
TYP: x2x30000000000XX Dim Ref Fmt
Upper Result Line X ower Result Line
If ANSI criteria selected, after additional scan grades obtained
TYP: ,000000000000Kx SYMBOL GRADE
X.X/06/660 xX 05 of 10 scans
TYP: 2000000000XXXXX FINAL SYMBOL GRD
X.X/06/660 xX 10 of 10 scans
Print Results Selected
If Printer not Available
If Printer is Available
OOPS! No Printer Connected -Store- Instead? (Select = "Yes')
Print... * All Stored Results * Latest Result Only * (Clear Buffer ?)
| When # Scans/Symboi satisfied
Page 105
‘ if Highlight Calculate "X" { Highlight Reflectometer | Highlight Change
Settings & Press & Press SELECT & Press SELECT SELECT
* Specifications
Symbol Measures 00% : aod : © Test Criteria 0.000 Inches -OoOoO- © Scanning Optior Reflectence -OOO- ¢ Output Option
Enter measured size & If metric unit, select "Centim" Press SELECT see
Quick Check® 600/800 Series User’s Guide page Symbol Measures 4 X.XXX Inches or “Centim" => "X"=X.XXXX in. AvgBar=+X.XXXX in.
see page
10-3
Page 106
10-4
Highlight Specifications & press SELECT
+ ak biked < Symbologies >| = UPC/EAN ON [> mites cocneecnestneneennee *Code39 ON nabled? Yes i" ABCD ** * Supple r * Int 2/5 ON ** Mag Factor: 100% * LOGMARS Le, mt *Code 128 ON Expand UPC-EO? No i UCC/EAN-ITF * Customer *Codabar ON * UCC/EAN-128 *Code 11 ON Code 39 * HIBCC ‘ee UCC/EAN-ITF- *Code 16K OFF eee *Enabled? Yes * CCBBA > *Code 49 OFF * Check Character * SISAC Mag Factor: xx% *MSI Code OFF
BOOKLAND * Fixed W/N OFF
* DATABASE in *Fixed Len OFF
--None--
-BOOKLAND-, Code 128
Mag Factor: 0% * Enabled? Yes ag Factor: xx* * Fixed Message Length * Modes Shown? Y
* Symbgy: -None- v * Length: 010 Chrs
Re
* Fixed W/N Ratio Select Option : ip} * Symbgy: -None-
* Append DBase Msg * Ratio: >
: XChange Msg w Scan atio; 2.5 + 0. Verify Only
%¥e=Highlight & press SELECT
Quick Check® 600/800 Series User’s Guide
Page 107
Quick Check® 600/800 Series User’s Guide
10-5
__Y
Highlight Highlight Test Criteria & Scanning press SELECT Options & press SELECT
* Passing: ANSI "C" * Decodability: ANSI * Grades: Letters
* #Scans/Symbol: 10
* Beeper Pitch 16 * Extended Accur Off * Decoding: BothWays|
Highlight Output Options & press SELECT
Vv Highlight & press nt . SELECT |* UpperLine: Default Display Options |- - - - - P|- LowerLine: Default
+ Dy . * Error Override: Y Printout Options * LEDs: P/F Criteria
Highlight & press SELECT
* Printer Type: HSP * Printout: Long Pi * AutoPrint/Stor On * w/Profile? No
Page 108
10 - 6
Quick Check® 600/800 Series User’s Guide
Page 109
Single-Scan-to-Result Codes (SSTR) Parameter SSTR Codes
Average Bar Error W/N Ratio Decodability R (1): R(d)
P.C.S.
Symbol Contrast Rmin/Rmax Modulation
EC (min) Defects Symbol Type Message Length
Quick Check® 600/800 Series User’s Guide
Custom SSTR Codes
Default Instal] Upper Line Instal]} Lower Line Save Settings
Il-1 q
SSTR Codes
Page 110
11 - 2
Quick Check® 600/800 Series User’s Guide