Page 91

to:

* Print Results * Calculate "X" * % Decoded/Scanned * Change Settings When the new * appears:

% Decoded/Scanned option is selected, this screen Symbol Grade: -------% Scans Decoded ---% Scans Passed Decoded nnn of nnn

An example of this completed screen would be:

Symbol Grade: A-3.8 100% Scans Decoded 95% Scans Passed Decoded 20 of 30 Symbol Grade is the running average grade of the symbol being tested based upon the average of the individual scan grades for the scans decoded within the total run of scans. The individual scan grades are weighted as shown below: A = 4.0 B = 3.0 C = 2.0 D = 1.0 F = 0.0 The numeric average mapping to the displayed grade is shown below: 3.5 ≤ A ≤ 4.0 2.5 ≤ B ≤ 3.5 1.5 ≤ C ≤ 2.5 0.5 ≤ D ≤ 1.5 0.0 ≤ F ≤ 0.5

% Scans Decoded is the percent of scans successfully decoded out of the total number of scans that were made. % Scans Passed is the percent of decoded scans that met or exceeded the minimum required ISO/IEC grade set in the unit. Decoded is the total number of scans successfully decoded compared to the total number of scans made. The maximum number of scans that will be made is based on the number of scans set in the * #Scans/Symbol: line option found in the menu chain:

Quick Check® 600/800 Series User’s Guide

8-3

Page 92

* Change Settings * Test Criteria * #Scans/Symbol: nnn Since the Scan Profile output capability does not exist with the QC3800V connected, the Printer Output screen also changes. The program sequence for that display is:

* Change Settings * Output Options * Printout Options * Printer Type: HSP * Printout: Long * AutoPrint/Stor On

8-4

Quick Check® 600/800 Series User’s Guide

Page 93

9 Error, Application, and Type Messages Type

Display Message

Printout Message

GENERAL

BAD # System

BAD Number System

BAD 2nd Chek

BAD 2nd Check Chr

BAD Addm Chk

BAD Addendum Check

BAD AlphaNum

BAD AlphanumericField

BAD Char Seq

BAD Char Sequence

BAD CheckChr

BAD Symbol Check Chr or Check Charctr Fails BAD or ModCheck Fails BAD

BAD CtrGuard

BAD Center Guard Patrn

BAD LH Guard

BAD Left Guard Pattern

BAD Msg Chek

BAD Message Check

BAD Numbers

BAD Numeric Field

BAD RH Guard

BAD Right Guard Pattrn

BAD Separatr

BAD Seperator

BAD User Chk

BAD User Check Chr

ILLEGAL Chr

ILLEGAL Character

MISSING S/S

MISSING Start/Stop

No Check Charctr

No Check Character

OK Check Chr

Check Charctr Passes OK! or ModCheck Passes OK!

SHORT LH Q-Z

BAD Left Quiet Zone

SHORT RH Q-Z

BAD Right Quiet Zone

UNRECOGNIZED

UNRECOGNIZED symbology

WIDE I-C Gap

WIDE I-C Gaps

% Mag Factor

U.P.C.:(or EAN:) xxx% Mag Factor

Quick Check® 600/800 Series User’s Guide

9-1

Page 94

Type

Display Message

Printout Message

DATABASE

Match

Match

NOT in DBase

NOT in Database

AdvShipmnt

Adv Shipmnt Notice

Authoriz #

Authorization #

BAD ID Char.

BAD ID Character

BAD UnitMeas

BAD Unit of Measure

Bookland

Bookland

DestPostCd

Dest. Postal code

EAN ITF-14

EAN ITF-14

EAN-13

EAN-13

Package ID

Package ID

Product ID

Product ID

PurOrder #

Purchase Order #

Qty/UofMes

Quantity/UofMeas

SupID/Prt#

Supl ID / Part #

SupID/Ser#

Supl ID / Serial#

Supplier ID

ID Code (Supl)

UCC/EAN128

UCC/EAN-128

UPC-A

UPC-A

Actual Wgt

Actual Weight

BAD ID Char

BAD ID Character

BAD Source

BAD Source Code

BAD Trace Fd

BAD Trace Field

Container

Container Type

Cust Part #

Part # (Cust)

CustmrDefn

Customer Defined

CustOrder#

Order # (Cust)

CustProdID

Product ID (Cust)

CustTrace#

Trace # (Cust)

ABCD

AIAG

9-2

Quick Check® 600/800 Series User’s Guide

Page 95

Type

Display Message

Printout Message

ECV /VCVS

ECV /VCVS

Emissn Test

Emissions Test

Employee#

Employee Pass ID

EngrChgLv1

Engr change Level

Gross Amt.

Gross Amount

HeatProcss

Heat/Process #

Internal

Internal Only!

Len /Weight

Length/theor.Wgt

MastrSerl#

Serial # (Master)

MixedSerl#

Serial # (MixedLd)

Net Amount

Net Amount

NO Separator

Missing Separator

Part# cont

Part# (cont)

Quantity

Quantity

ReturnCode

Return Code

Serl#(Itm)

Serial # (Item)

Serl#Pkg

Serail # (Pack)

Stock Locn

Stocking Location

Supl Part#

Part# (Supl)

Supl&Part#

Supplier .Part #

SuplOrder#

Order # (Supl)

SuplTrace#

Trace# (Supl)

Suppl Defn

Supplier Defined

Suppl (Cus)

Supplier (Cust)

Suppl (Sup)

Supplier (Supl)

Trans Defn

Transport Defined

UnlistedID

Unlisted ID Char

UofMeasure

Unit of Measure

“VIN” #

Vehicle ID Number

Quick Check® 600/800 Series User’s Guide

9-3

Page 96

Type

Display Message

Printout Message

BOOKLAND

Andorra

Andorra

Argentna

Argentina

BAD Publsh #

BAD Publisher #

Bangldsh

Banglasdesh

Botswana

Botswana

Brazil

Brazil

Bulgaria

Bulgaria

Caribben

Caribbean

Chile

Chile

China

China

Colombia

Colombia

CostaRic

Costa Rica

Croatia

Croatia

Cuba

Cuba

Cyprus

Cyprus

Czechlov

Czechoslovakia

Denmark

Denmark

Egypt

Egypt

EnglSpkg

English Speaking

Equador

Equador

Finland

Finland

FrenSpkg

French Speaking

Gambia

Gambia

GermSpkg

German Speaking

Ghana

Ghana

Greece

Greece

HongKong

Hong Kong

9-4

Hungary

Hungary

Iceland

Iceland

Quick Check® 600/800 Series User’s Guide

Page 97

Type

Display Message

Printout Message

India

India

Indonesa

Indonesia

Israel

Israel

Italy

Italy

Japan

Japan

Kenya

Kenya

Korea

Korea

Lesotho

Lesotho

Malawi

Malawi

Malaysia

Malaysia

Maldives

Maldives

Malta

Malta

Mauritis

Mauritius

Mexico

Mexico

Morocco

Morocco

N.Antils

Neth.Antilles

Namibia

Namibia

Netherld

Netherlands

Message on Display

Message on Printout

Nigeria

Nigeria

Norway

Norway

NOT Bookland

NOT Bookland

Pakistan

Pakistan

PapNGuna

Papua N.Guinea

Philppns

Philippines

Poland

Poland

Romania

Romania

RussSpkg

Russian Speaking

S.Pacifc

S.Pacific

Quick Check® 600/800 Series User’s Guide

9-5

Page 98

Type

CCBBA

9-6

Display Message

Printout Message

Singpore

Singapore

Slovinia

Slovinia

Spain

Spain

SriLanka

Sri Lanka

Suriname

Suriname

Sweden

Sweden

Taiwan

Taiwan

Tanzania

Tanznaia

Thailand

Thailand

Tunesia

Tunesia

Turkey

Turkey

Unesco

Unesco

Uruguay

Uruguay

Venzuela

Venezuela

Yugoslav

Yugoslavia

Zambia

Zambia

Attribute

Attribute

Autol Use

AutologusUse Only

BAD CtrlCode

BAD Control Code

BAD GroupCod

BAD Grouping Code

Biohazard

Biohazard

BloodProd

Blood Product

Dir Donor

Directed Donor

Donation#

Donation #

EmergyUse

Emergency Use Only

ExpirDate

Expiration Date

FDA Reg#

FDA Regis. #

GroupLbl

Grouping Label

Hold!

Hold for procsng

Quick Check® 600/800 Series User’s Guide

Page 99

Type

HIBCC

Display Message

Printout Message

Hospital#

Hospital #

Irradiatd

Irradiated

NegAntCMV

Neg for Anti-CMV

NotTransf

Not For Transfn

Obsolete Fmt

Obsolete Format

PatientID

Pat ID (Blood Bg)

PatientID

Pat ID (Sample)

PatientID

Pat ID (Wrist)

PersonlID

Personnel ID#

PrimryBag

Primary Col Bag

ThPhlebty

Frm TherPhlebtmy

TrnsfrBag

Transfer Bag

Type A

Blood Type A

Type A+

Blood Type A+

Type A-

Blood Type A-

Type AB

Blood Type AB

Type AB+

Blood Type AB+

Type AB-

Blood Type AB-

Type B

Blood Type B

Type B+

Blood Type B+

Type B-

Blood Type B-

Type O

Blood Type O

Type O+

Blood Type O+

Type O-

Blood Type O-

Alternat*

Alternate*

Alternate

Alternate

AltSecndry

Alter.Secondary

BAD # System

BAD # System

BAD Date

BAD Date

Quick Check® 600/800 Series User’s Guide

9-7

Page 100

Type

Display Message

Printout Message

BAD Descrptr

BAD Descriptor

BAD Flags

BAD Flags

BAD Indus.ID

BAD Industry ID

BAD Quantity

BAD Quantity

BAD UnitMeas

BAD Unit of Measure

(EAN ITF)

(SCS /ITF)

Prim/Sec*

Primary/Secondary*

Prim/Secd

Primary/Secondary

Primary

Primary

Primary*

Primary*

Provider

Provider

Provider*

Provider*

Secondary

Secondary

Secondry*

Secondary*

(UPC/EAN)

(UPC/EAN)

Messages with an asterisk (*) indicate the symbol was created in Code 128. LOGMARS

LOGMARS:-OK!

LOGMARS:-OK!

SISAC

BAD Descrpter

BAD Descriptor

BAD ISSN

BAD “ISSN”

BAD Version#

BAD Version #

Ver 1 ‘92

Ver “1” (1992)

Ver O ‘87

Ver “O” (1987)

BAD LogVarnt

BAD Logis. Variant

BAD Prefix

BAD Prefix

FixdCon

Fixed Content

ITF-14

ITF-14

ITF-16

ITF-16

UCC/EAN-ITF

9-8