Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 24

IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide: Symbologies, pages 71 to 79

Pages 71 to 79 of 216, from IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP IT4410 and HHP IT4710

Page 71

3 Symbologies Introduction Use this section to program the hand-held Imager. This programming section contains the following menuing selections: • Linear Symbology Selections • Stacked Symbology Selections • Postal Symbology Selections • 2D Matrix Symbology Selections • Diagnostics

3-1

Page 72

Linear Symbologies Codabar <Default All Codabar Settings>

Codabar

* On

Off

Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters.

Start/Stop Transmit

* Don’t Transmit Start/Stop

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3-2

Page 73

Linear Symbologies Codabar, continued Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, But Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate, And Transmit, the scanner will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.

* No Check Character

Validate, But Don’t Transmit

Validate, And Transmit

3-3

Page 74

Linear Symbologies Code 39 < Default All Code 39 Settings >

Code 39

* On

Off

Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters.

Transmit

* Don’t Transmit

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Maximum Message Length Message Length The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3-4

Page 75

Linear Symbologies Code 39, continued Full ASCII If Full ASCII Code 39 decoding is turned on, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. NUL %U

DLE $P

SP

SPACE 0

0

@

%V

P

P

‘

W p

+P

SOH $A

DC1 $Q

!

/A

1

1

A

A

Q

Q a

+A q

+Q

STX $B

DC2 $R

“

/B

2

2

B

B

R

R b

+B r

+R

ETX $C

DC3 $S

#

/C

3

3

C

C

S

S c

+C s

+S

EOT $D

DC4 $T

$

/D

4

4

D

D

T

T d

+D t

+T

ENQ $E

NAK $U

%

/E

5

5

E

E

U

U e

+E u

+U

ACK $F

SYN $V

&

/F

6

6

F

F

V

V f

+F v

+V

BEL $G

ETB $W

‘

/G

7

7

G

G

W

W g

+G w

+W

BS

$H

CAN $X

(

/H

8

8

H

H

X

X h

+H x

+X

HT

$I

EM

$Y

)

/I

9

9

I

I

Y

Y i

+I y

+Y

LF

$J

SUB $Z

*

/J

:

/Z

J

J

Z

Z j

+J z

+Z

VT

$K

ESC %A

+

/K

;

%F

K

K

[

%K k

+K

{

%P

FF

$L

FS

%B

,

/L

<

%G L

L

\

%L l

+L

|

%Q

CR

$M

GS

%C

-

-

=

%H

M

M

]

%M m

+M

}

%R

SO

$N

RS

%D

.

.

>

%I

N

N

^

%N n

+N

~

%S

SI

$O

US

%E

/

/O

?

%J

O

O

_

%O o

+O

DEL %T

Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.

Full ASCII On

* Full ASCII Off

3-5

Page 76

Linear Symbologies Code 39, continued Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, But Don’t Transmit, the unit will only read Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate, And Transmit, the scanner will only read Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data.will transmit this character at the end of the scanned data.

* No Check Character

Validate, But Don’t Transmit

3-6

Validate, And Transmit

Page 77

Linear Symbologies Code 11 < Default All Code 11 Settings >

Code 11

On

* Off

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3-7

Page 78

Linear Symbologies Code 11, continued Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes.

One Check Digit

3-8

* Two Check Digits

Page 79

Linear Symbologies Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings >

Interleaved 2 of 5

* On

Off

Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15

Minimum Message Length

Maximum Message Length

The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3-9