Data Formatter When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes).
* On/Not Required
Off
Require Data Format When Data Formatter is Required, all input data must conform to an edited format or the scanner does not transmit the input data to the host device.
Required
Show Data Formats Read the Show Data Formats bar code to transmit the existing data formats. One format per line is printed out.
Show Data Formats
2 - 41
Page 62
Alternate Data Formats Alternate formats allow you “single shot” capability to scan one bar code using a different data format than your primary format. When data formats are programmed (see page 2-37), you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3. An alternate format is initiated by scanning one of the 3 alternate format bar codes below. The scanner will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format.
Alternate Data Format 1
Alternate Data Format 2
Alternate Data Format 3
2 - 42
Page 63
Output Sequence Overview Output Sequence Editor This programming selection allows you to program the Imager to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the Imager to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol.
Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires. Use the Alphanumeric symbols (inside back cover) to read these options. To Add an Output Sequence 1. Scan the Enter Sequence symbol (see "Output Sequence Editor" on page 2-46). 2. Code I.D. On the "Symbology Chart" on page 2-35, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) 4. Character Match Sequences On the "Decimal to Hex to ASCII Conversion Chart" on page 2-36, find the Hex value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters. (99 is the Universal number, indicating all characters.) 5. End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology, or Save Current Output Sequence Changes to save your entries.
Other Programming Selections • Discard Current Output Sequence Changes This exits without saving any Output Sequence changes.
Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.
2 - 43
Page 64
Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93 You would set up the sequence editor with the following command line: SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below: SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39, 9999 = all lengths 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128, 9999 = all lengths 42 start character match for Code 128, 42h = “B” FF termination string for second code 69 code identifier for Code 93 9999 code length that must match for Code 93, 9999 = all lengths 43 start character match for Code 93, 43h = “C” FF termination string for third code
2 - 44
Page 65
Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence, but if it cannot, the scanner transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the scanner decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Required
On/Not Required
Off
2 - 45
Page 66
Output Sequence Editor
Enter Sequence †
Default Sequence
Exit Selections
Save Current Output Sequence Changes
Discard Current Output Sequence Changes
Note: If you want the scanner to beep after each bar code is read, please see "Output Sequence Beeper" on page 2-27. † One or more two digit numbers and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
2 - 46
Page 67
Multiple Symbols Note: This feature does not work when the Imager is in Low Power mode. When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the Imager’s trigger. If you press and hold the trigger, aiming the Imager at a series of symbols, it reads unique symbols once, beeping (if turned on) for each read. Data is output as the imager finds and decodes the symbols. The imager attempts to find and decode new symbols as long as the trigger is pulled. When this programming selection is turned Off, the Imager will only read the symbol closest to the aiming beam.
On
* Off
No Read With No Read turned On, the Imager notifies you if a code cannot be read. In the Quick*View Scan Data Window (see "Scan Data Window" on page 7-4), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear.
On
* Off
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message using the Data Formatter (see page 2-37). The hex code for the No Read symbol is 9C.
2 - 47
Page 68
Print Weight Print Weight is used to adjust the way the scanner reads Matrix symbols. If a scanner will be seeing consistently heavily printed matrix symbols, then a print weight of 6 may improve the reading performance. For consistently light printing, a print weight of 2 may help. A value from 0 to 7 may be used to adjust the print weight. The default print weight is 4.
† Set Print Weight
* Default
† A one digit number from 1 to 7 is required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Chapter 9, Supported Interface Keys. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.
* On
2 - 48
Off
Page 69
Video Reverse Video Reverse is used to allow the imager to read bar codes that are inverted. The “Off” bar code below is an example of this type of bar code. If additional menuing is required, Video Reverse must be disabled to read the menu bar codes and then re-enabled after menuing is completed.
Note: Images downloaded from the unit will not be reversed. This is a setting for decoding only.
On * Off
2 - 49
Page 70
2 - 50