Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string:

Prefix 1-10 alpha numeric characters

Scanned Data variable length

Suffix 1-10 alpha numeric characters

Points to Keep In Mind • It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. Default prefix = None. Default suffix = CR/LF. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the "Decimal to Hex to ASCII Conversion Chart" on page 2-36, plus Code I.D. and Aim I.D. • You can string together several entries for several symbologies at one time. • Enter prefixes and suffixes in the order in which you want them to appear on the output.

2 - 31

Page 52

Adding a Prefix or Suffix 1. Scan the Add Prefix (page 2-34) or Add Suffix symbol (page 2-34). 2. Determine the 2 digit Hex value from the "Symbology Chart" on page 2-35 for the symbology to which you want to apply the prefix or suffix. 3. Scan the 2 hex digits from the Programming Chart inside the back cover or scan 9, 9 for all symbologies. 4. Determine the hex value from the "Decimal to Hex to ASCII Conversion Chart" on page 2-36 for the prefix or suffix you wish to enter. 5. Scan the 2 digit hex value from the Programming Chart inside the back cover.

Note: Repeat Steps 4 and 5 for every prefix or suffix character. Note: To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C. 6. Scan Save to exit and save, or scan Discard to exit without saving. Repeat Steps 1-6 to add a prefix or suffix for another symbology. Example: Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for UPC only: 1. Scan Add Suffix. 2. Determine the 2 digit hex value from the "Symbology Chart" on page 2-35 for UPC. 3. Scan 6, 3 from the Programming Chart (inside back cover). 4. Determine the hex value from the "Decimal to Hex to ASCII Conversion Chart" on page 2-36 for the CR (carriage return). 5. Scan 0, D from the Programming Chart (inside back cover). 6. Scan Save, or scan Discard to exit without saving.

Clearing One or All Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. 1. Scan the Clear One Prefix symbol. 2. Determine the 2 digit Hex value from the "Symbology Chart" on page 2-35 for the symbology from which you want to clear the prefix or suffix. 3. Scan the 2 digit hex value from the Programming Chart inside the back cover or scan 9, 9 for all symbologies. Your change is automatically saved.

2 - 32

Page 53

Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a Carriage Return/Line Feed Suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.

Add CR/LF Suffix All Symbologies

Add a Code I.D. Prefix to All Symbologies This selection allows you to turn on (or off) transmission of a Code I.D. before the decoded symbology. (See the "Symbology Chart" on page 2-35 for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies.

Add Code ID Prefix All Symbologies

Add an AIM I.D. Prefix to All Symbologies This selection allows you to turn on (or off) transmission of an AIM I.D. before the decoded symbology. (See the "Symbology Chart" on page 2-35 for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs an AIM I.D. prefix for all symbologies.

Add AIM ID Prefix All Symbologies (See AIM Guidelines on Symbology Identifiers for more information on the AIM symbology ID characters.)

2 - 33

Page 54

Prefix Entries

Clear One Prefix †

Add Prefix †

Clear All Prefixes

Suffix Entries

Add Suffix †

Clear One Suffix †

Clear All Suffixes † One or more two digit numbers and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).

Exit Selections

Save

2 - 34

Discard

Page 55

Symbology Chart Symbology

Code AIM ID ID

Hex ID

Symbology

Code AIM ID ID

Hex ID

Australian 4 State

A

]X

41

Interleaved 2 of 5 e

]l

65

Aztec Code z

]z

7A

Japanese Postal

J

]X

4A

BC412** g

]X

67

Kix (Dutch) Postal

K

]X

4B

BPO 4 State

B

]X

42

Maxicode x

]U

78

Canadian 4 State

C

]X

43

Micro PDF417

R

]L

52

Codabar a

]F

61

MSI g

]M0

67

Codablock-F q

]O

71

No Read

Code 11 h

]H0

68

OCR o

]Y

6F

Code 39 b

]A

62

PDF417 r

]L

72

Code 49 l

]T

6C

Planet Code

L

]X

4C

Code 93 i

]G

69

Postnet

P

]X

50

Code 128 j

]C

6A

QR Code s

]Q

73

Code Z** u

]X

75

RSS/Composites y

]e

79

Data Matrix w

]d

77

UPC c

]E

63

EAN d

]E

64

Vericode** v

]V

IATA 2 of 5 f

]R

66

All Symbologies †

9C

76

99

Note: Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Note: † All Symbologies: Prefix/Suffix programming only! Note: ** Not available in standard product. Only available when ordered in custom firmware

2 - 35

Page 56

Decimal to Hex to ASCII Conversion Chart Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

SP ! “ # $ % & ‘ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

@ A B C D E F G H l J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

‘ a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL

2 - 36

Page 57

Data Format Editor Overview The Data Format Editor selections are used to edit scanned data. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. It is not necessary to use the Data Format Editor. A set of defaults for the data format is already programmed in the scanner. The selections in the following pages are used only if you wish to alter the default settings. Default Data Format setting = none. If you have changed data format settings, and wish to clear all formats and return to the defaults, scan the Default Data Format code. To Add a Data Format 1. Scan the Enter Data Format symbol (page 2-40). 2. Primary/Alternate Format Determine if this will be your primary data format, or one of 3 alternate formats. (Alternate formats allow you “single shot” capability to scan one bar code using a different data format. After the one bar code has been read, the scanner reverts to the primary data format. See "Alternate Data Formats" on page 2-42.) If you are programming the primary format, scan 0. If you are programming an alternate format, scan 1, 2, or 3, depending on the alternate format you are programming. 3. Terminal Type Refer to the "Supported Terminals Chart" on page 2-5 and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge.

Note: The wildcard for all terminal types is 099. 4. Code I.D. On page 2-35, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart. 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) 6. Editor Commands Refer to the "Format Editor Commands" on page 2-38. Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format. 7. Scan Save to save your entries.

2 - 37

Page 58

Other Programming Selections • Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0. If you are clearing an alternate format, scan 1, 2, or 3, depending on the alternate format you are clearing. Scan the Terminal Type (refer to the "Supported Terminals Chart" on page 2-5), Code I.D. and the length of the format you want to delete. That length data format for that symbology is deleted and all other formats are unaffected. • Save This exits, saving any Data Format changes. • Discard This exits without saving any Data Format changes.

Format Editor Commands Send Commands F1 Send all characters followed by “xx” key or function code, starting from current cursor position. Syntax = F1xx (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 236.) F2 Send “nn” characters followed by “xx” key or function code, starting from current cursor position. Syntax = F2nnxx (nn stands for the numeric value (00-99) for the number of characters and xx stands for the hex value for an ASCII code. See "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) F3 Send up to but not including “ss” character (Search and Send) starting from current cursor position, leaving cursor pointing to “ss” character followed by “xx” key or function code. Syntax = F3ssxx (ss and xx both stand for the hex values for ASCII codes, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36, and nn is the numeric value (00-99) for the number of times it should be sent.) E9 Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (nn is the numeric value (00-99) for the number of characters that will not be sent at the end of the message.) Move Commands F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved ahead.) F6 Move the cursor back “nn” characters from current cursor position. Syntax = F6nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved back.) F7 Move the cursor to the beginning of the data string. Syntax = F7. EA Move the cursor to the end of the data string. Syntax = EA

2 - 38

Page 59

Search Commands F8 Search ahead for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F8xx (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) F9 Search back for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F9xx (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) E6 Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non ”xx” character. Syntax = E6xx (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) E7 Search back for the first non “xx” character from the current cursor position, leaving cursor pointing to non ”xx” character. Syntax = E7xx (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) Miscellaneous Commands FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number suppress characters in the list and xxyy .. zz is the list of characters to be suppressed. (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) FC Disable suppress filter and clear all suppressed characters. Syntax = FC. E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. E5 Terminates character replacement. Syntax = E5. FE Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see "Decimal to Hex to ASCII Conversion Chart" on page 2-36.) EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC. ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED.

2 - 39

Page 60

Data Format Editor See page 2-37 through page 2-39 for a description of Data Format selections and commands.

Enter Data Format †

Default Data Format (none)

Clear One Data Format †

Clear All Data Formats

Exit Selections

Save Current Data Format Changes

Discard Current Data Format Changes † One or more two digit numbers and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).