The text of a manual · part 5 of 24
IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide: Programming, pages 41 to 50
Pages 41 to 50 of 216, from IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT4410 and HHP IT4710
Page 41
The figure below illustrates the default top, bottom, left, and right pixel positions. The position of the pixels is measured from the top and the left side of the imager’s field of view with the field of view being 640 by 480 pixels. 290
350
0
640
Top
210
Bottom
Default Center
270
Left Right 480
2 - 21
Page 42
Top of Centering Window
Top of Centering Window Default (210)
Bottom of Centering Window
Bottom of Centering Window Default (270)
Left of Centering Window
Left of Centering Window Default (290)
Right of Centering Window
Right of Centering Window Default (350)
2 - 22
Page 43
In the example below, the gray area is the full imager field of view and the white area is the centering window. Bar Code 1 will not be read, while Bar Code 2 will be. Bar Code 1
Bar Code 2
AutoTrigger Two AutoTrigger Modes are available: Scan Stand and Presentation Mode. When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol. (See Scan Stand Symbol that follows.) When a different code is presented, the Imager is triggered to read the new code.
Note: The scanner automatically adjusts the illumination LEDs to the lowest light level possible to maintain a good lock on the Scan Stand symbol. Presentation mode is for those applications where a scan stand will not work, i.e., when large packages must be scanned. To program the device for presentation mode, refer to "Presentation Mode" on page 2-24.
2 - 23
Page 44
Scan Stand This selection programs the Imager to work in a Scan Stand.
* Off
On
Scan Stand Symbol Note: Scan Stand mode does not work when scanner is programmed for the HHLC interface. When a unit is in Scan Stand mode, the LEDs shine at the Scan Stand symbol on the base of the stand which tells it to remain idle. When the Scan Stand symbol is covered, the imager turns the LEDs on at the configured power level (Default High) and attempts to find and decode bar codes in its field of view.
Scan Stand Symbol
Presentation Mode Note: Presentation Mode does not work when scanner is programmed for the HHLC interface. This programs the scanner to work in Presentation Mode.
* Off
On
Presentation Re-trigger Delay This sets the time period before the scanner can re-trigger for another read attempt. Setting a re-trigger delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads at POS (point of sale). Use shorter delays in applications where repetitive bar code
2 - 24
Page 45
scanning is required. Entries are in milliseconds, from 1 to 10,000. Scan the Presentation Re-trigger Delay bar code below, then scan the number of milliseconds and the Save bar code from the inside back cover. Default = 200.
Presentation Re-trigger Delay
Presentation Lights When using the scanner in presentation mode, the illuminating LEDs can be programmed on or off. If there is sufficient ambient light, the LEDs can be turned off by scanning the Lights Off bar code below. When a bar code is presented to the scanner, the illuminating LEDs turn on to scan the bar code and then turn off when the bar code has been read. Default = Presentation Mode Lights On.
* On
Off
Presentation Default Defaults all presentation mode settings. Defaults = Presentation Mode Off, Presentation Reread Delay 200 ms.
Presentation Default
2 - 25
Page 46
Fast Omni Mode Normally, the imager searches throughout its whole field of view to determine if a bar code is present. Fast omni-directional mode provides a reduced search pattern that increases the scan rate of the imager. When fast omni mode is enabled, the imager only tries to locate bar codes in the center area of the image. Consequently, the user is required to center the aiming line over the bar code he wants to read. When a portion of the bar code is in the center area of the image, the imager locates and decodes the bar code. The entire bar code does not need to be in the center area, only a portion of it. Bar codes that are not in the center area of the image will not be found.
Note: Fast Omni Mode is not recommended when scanning Data Matrix codes.
* Normal, Full Search Mode
Reduced Omnidirectional Mode
Beeper Volume
2 - 26
Off
Low
Medium
* High
Page 47
Power Up Beeper
* On
Off
Output Sequence Beeper If you are using an Output Sequence (see "Output Sequence Overview" on page 2-43), you may want to hear a beep after each bar code as it is read. Scan Output Sequence Beeper On to enable this feature, or Off to disable it.
Off
* On
Beep On Decode If you want the scanner to beep each time it reads a bar code, leave this setting On. If you don’t want it to beep on each read, but do want it to beep for other events, such as error conditions, set this selection to Off.
Off
* On
Beeper Default Defaults all beeper settings. Defaults = Beeper Volume High, Power Up Beeper On, Output Sequence Beeper On, Beep On Read On.
Beeper Default
2 - 27
Page 48
Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data increasing data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each).
Intercharacter Delay Note: This selection is valid for keyboard wedge interfaces only. This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each character of scanned data. You can program up to 99 steps (of 5 ms each). Scan the Intercharacter Delay bar code below, then scan the number of steps, and the Save bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again. Prefix
Scanned Data 1
2
3
4
Suffix 5
Intercharacter Delay
Intercharacter Delay To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 00. Scan the Save bar code from the inside back cover.
User Specified Intercharacter Delay Note: This selection is valid for keyboard wedge interfaces only. This is a delay of up to 495 milliseconds (in multiples of 5) placed after the transmission of a particular character of scanned data. You can program up to 99 steps (of 5 ms each) to follow the character you specify. Scan the Delay Length bar code below, then scan the number of steps for the delay, and the Save bar code from the inside back cover.
2 - 28
Page 49
Next, scan the Character to Trigger bar code, then the 2 digit hex value for the ASCII character that trigger the delay (refer to the "Decimal to Hex to ASCII Conversion Chart" on page 2-36).Note:If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again.
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length bar code, then set the number of steps to 00. Scan the Save bar code from the inside back cover.
Interfunction Delay Note: This selection is valid for keyboard wedge interfaces only. This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each segment of the message string. You can program up to 99 steps (of 5 ms each). Scan the Interfunction Delay bar code below, then scan the number of steps, and the Save bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again. Prefix STX
1
Scanned Data HT
2 3 4 5
Suffix CR
LF
Interfunction Delays
Interfunction Delay To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 00. Scan the Save bar code from the inside back cover.
Intermessage Delay Note: This selection is valid for keyboard wedge interfaces only.
2 - 29
Page 50
This is a delay of up to 495 milliseconds (in multiples of 5) placed between each scan transmission. You can program up to 99 steps (of 5 ms each). Scan the Intermessage Delay bar code below, then scan the number of steps, and the Save bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again.
1st Scan Transmission
2nd Scan Transmission
Intermessage Delay
Intermessage Delay To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 00. Scan the Save bar code from the inside back cover.
2 - 30