Baud Rate This sets the baud rate from 300 bits per second to 115,200 bits per second (see next page). Programming baud rate causes the data to be sent at the specified rate. The host terminal must be set to the same baud rate as the Imager to ensure reliable communication.
300
600
1200
2400
4800
9600
19200
* 38400
2 - 11
Page 32
Baud Rate, continued
57600
115200
Word Length Data Bits You can set the Word Length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.
7 Data Bits
* 8 Data Bits
Word Length Stop Bits Word Length can be set to one or two stop bits.
* 1 Stop Bit
2 - 12
2 Stop Bits
Page 33
Hardware Flow Control When hardware flow control is On, the software checks for a CTS signal before sending data. This option is useful when your application supports the CTS signal.
On
* Off
Software Flow Control This allows control of data transmission from the Imager using software commands from the host device. When this feature is turned Off, no data flow control is used. When Data Flow Control is turned On, the host device suspends transmission by sending the XOFF character (DC3, hex 13) to the Imager. To resume transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off when XOFF was sent.
On
* Off
2 - 13
Page 34
Serial Triggering This provides a means of sending a serial trigger command to start and stop decoding. When this feature is turned Off, the Imager will not respond to serial trigger commands. When serial triggering is turned On, the Imager requires a serial trigger character to activate scanning and decoding. The unit continues to scan and decode until the Trigger Off character turns off the scanner, a time out occurs, or a bar code is decoded. On the "Decimal to Hex to ASCII Conversion Chart" on page 2-36, find the hex characters you want to use to turn the trigger on and off. Locate the decimal values for those characters and scan the 2 digits for each one from the Programming Chart in the back of this manual.
When Serial Triggering is On, the default Trigger On decimal character is 18 (hex 12, DC2), and the default Trigger Off decimal character is 20 (hex 14, DC4).
On
* Off
Trigger On ‡
Trigger Off ‡
* Trigger Defaults
Note: ‡ A one to three digit decimal number and Save are required after reading this programming symbol. See "Decimal to Hex to ASCII Conversion Chart" on page 2-36, and the Programming Chart (inside back cover).
2 - 14
Page 35
Trigger Timeout Use this selection to set a timeout (in quarter seconds) of the Imager’s trigger. Once the imager has timed out, it must be triggered again either serially (see "Serial Triggering" on page 2-14), or manually. Set the Trigger Timeout to 00 if you don’t want a Trigger Timeout. Default setting = 120 seconds
Set Timeout ‡
Note: ‡ A one- to three digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
2 - 15
Page 36
Power Saving Mode This provides control of the Imager’s power consumption, as follows:
Low Power draws low (50%) LED current during image capture, allowing one read attempt only for each trigger pull. The Imager is less tolerant of hand movement during the read attempt, and powers down after the image capture is complete. Medium Power draws a normal LED current during image capture which enhances motion tolerance. Medium Power attempts to read as long as the trigger is pulled, going into a “doze” (low power) state after each read attempt. The Imager powers down ten seconds after the image capture is complete. Normal Power draws a normal LED current, attempting to read as long as the trigger is pulled or a decode is in process. The Imager doesn’t go into a “doze” state after each read attempt, but will power down after two minutes if Power Hold Mode is turned Off.
Low Power
Medium Power
* Normal Power
2 - 16
Page 37
Power Hold Mode Power Hold On keeps the Imager in a ready to read state. To conserve power, this selection may be turned Off and the unit will power down if not used within two minutes. When you are ready to use the Imager again, restore power by pressing the trigger.
On
* Off
LED Power Level This selection allows you to adjust LED brightness.
Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting.
Off
Low
* High
2 - 17
Page 38
LED Flashing When LED Flashing is On, the LEDs and aiming light alternately flash until a symbol is decoded or the trigger is released. If LED Flashing is turned Off, the average current draw is increased and the aiming light won’t illuminate while the scanner reads a bar code. The LEDs remain on while the scanner is reading.
Off
* On
Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken. Use these codes to set the time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over.
200 milliseconds
400 milliseconds
* Off (no delay)
2 - 18
Page 39
Aimer Interval Aimer Interval turns off the aiming light, or programs the aimer to come on at certain intervals when reading symbols with the scanner. You may program the scanner to use the aimer Every Read, Every Second Read, or Every Third Read. You may also program the scanner to use the aimer every “x” reads, by entering a number from 0 to 999 to indicate “x.”
Off
* Every Read
Every Second Read
Every Third Read
Every “x” Reads ‡
Note: ‡ A one- to three digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
2 - 19
Page 40
Centering Use the centering feature to narrow the imager’s field of view to make sure that the imager reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. When centering is turned on, the imager only reads codes that intersect the centering window set up by the user. The centering window must intersect the center of the image. If a bar code is not within the predefined window, it will not be decoded or output by the scanner. If centering is turned on by scanning the On bar code below, the default centering window is a 60 pixel square area in the center of the imager’s field of view. The position of the window may be changed by scanning the top, bottom, left, and right centering bar codes that follow and the appropriate pixel value, if other than the default, from the Programming Chart in the back of this manual. The defaults are listed in the table below. Window Position
Default
Minimum
Maximum
Serial Command
Top of centering window
210
000
239
DECTPYxxx
Bottom of centering window
270
240
479
DECBTYxxx
Left of centering window
290
0
319
DECTPXxxx
Right of centering window
350
320
639
DECBTXxxx
The centering function can be used in conjunction with the Aimer Delay feature (page 2-18) for the most error-free operation in applications where multiple codes are spaced closely together. Using the Aimer Delay and Centering features, the imager can emulate the operation of older systems, such as linear laser bar code scanners.
On
2 - 20
* Off