Page 21
2 Programming Introduction Use this section to program the hand-held or fixed mount Imager. This programming section contains the following menuing selections: • General Selections • Terminal Interface Selections • Keyboard Selections • Communication Settings • Imager Selections • Output Selections • Prefix/Suffix Selections • Data Formatter Selections • Output Sequence Selections
2-1
Page 22
Reset Factory Settings All operating parameters are stored in nonvolatile memory resident in the Imager, where they are permanently retained in the event of a power interruption. When you receive your Imager, certain operating parameters have already been set. These are the factory defaults, indicated by the symbol “✱” on the programming menu pages (beneath the default programming symbol). Default charts begin on page 5-1.
Default
Status Check Read the Show Software Revision symbol to transmit the software revision level to the host terminal. The software revision will be printed out as “REV_SW:$ProjectRevision:1.xx$;REV_WA:31204960-xxx.” Read the Show Data Formats symbol to transmit the existing Data Format Editor formats. One format per line will be printed out.
Show Software Revision
Show Data Formats
All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code.
All Symbologies On
2-2
All Symbologies Off
Page 23
Revision Selections Both the following programming codes would not normally be needed unless you have a problem with the unit. An Application Support Representative may request the boot code or power PC revision information in order to trouble shoot a problem.
Power PC Revision
Boot Code Revision
2-3
Page 24
Terminal Interface IMAGETEAM 4410 and IMAGETEAM 4710 scanners are factory programmed for a keyboard wedge interface to an IBM PC AT with a USA keyboard. If this is your interface and you do not need to modify the settings, skip to "Power Saving Mode" on page 2-16 to begin programming the scanner. If your interface is not a standard PC AT, refer to the "Supported Terminals Chart" on page 2-5 and locate the Terminal ID number for your PC. Scan the Terminal ID bar code below, then scan the numeric bar code(s) on the inside back cover of this manual to program the scanner for your terminal ID> Scan Save to save your selection. For example, an IBM PS/2 terminal has a Terminal ID of 002. You would scan the Terminal ID bar code, then 0, 0, 2 from the inside back cover, then Save. If you make an error while scanning the digits (before scanning Save), scan the Discard code on the back cover and scan the digits and the Save code again.
Note: Factory Default for Keyboard Wedge units = 003 Note: Factory Default for True RS-232 units = 000
Terminal ID
2-4
Save
Page 25
Supported Terminals Chart Terminal
Model(s)
DEC PC433 SE (Portable PC) DELL Latitude (Portable PC) DTK 486 SLC (Portable PC) Fujitsu Stylistic (Portable PC) HHLC (Code 128 Emulation) IBM PC XT IBM PS/2 25, 30, 77DX2 AT, PS/2 30-286, 50, 55SX, 60, 70, IBM 70-061, 70-121, 80 AT Compatibles Keyboard Emulation IBM (Non-wedge) Thinkpad 360 CSE, 34, 750 IBM (Portable PC) Thinkpad 365, 755 CV IBM (Portable PC) IBM AT Thinkpad Midwest Micro Elite TS 30 PS (Portable PC) Mitak 4022 (Portable PC) Olivetti M19, M24, M28, M200 Olivetti M240, M250, M290, M380, P500 Reliasys TR 175 RS-232 TTL Televideo 990, 995, 9060 Texas Instruments Extensa 560CD (Portable PC) Toshiba 2600 (Portable PC) Toshiba Satellite T1960, T2130, CS (Portable PC) Zenith Z-note (Portable PC)
Terminal I.D. 003 003 003 003 089 001 002 003 003 097 003 106 003 003 001 003 003 000 002 003 003 003 003
2-5
Page 26
Keyboard Country Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from the inside back cover, then the Save bar code to program the keyboard for your country. As a general rule, the following characters are not supported by the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~
Keyboard Country
Country Code Scan Belgium..................... 1 Czechoslovakia ........ 15 Denmark ................... 8 Finland...................... 2 France ...................... 3 French Canadian ...... 18 Germany/Austria....... 4 Great Britain ............. 7 Greece...................... 17 Netherlands .............. 11 Hungary .................... 19 Israel......................... 12 Italy ........................... 5
Country Code Scan Latin America .........14 Norway...................9 Poland....................20 Portugal .................13 Romania ................25 Russia ....................26 Slovakia .................22 Spain......................10 Sweden ..................23 Switzerland ............6 Turkey Q ................24 Turkey F.................27 USA (Default) .........0
Save
2-6
Page 27
Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. Default = Regular.
Regular is used when you normally have the Caps Lock key off. Caps Lock is used when you normally have the Caps Lock key on. Shift Lock is used when you normally have the Shift Lock key on. (Not common to U.S. keyboards.) Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED which notes the Caps Lock status.
* Regular
Caps Lock
Shift Lock
Automatic Caps Lock
Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). To connect to a laptop, you must scan the Emulate External Keyboard bar code below, then scan "Automatic Direct Connect Mode On" on page 2-8. After scanning these codes, you must re-boot your laptop.
Emulate External Keyboard
2-7
Page 28
Keyboard Modifiers This modifies special keyboard features, such as CTRL+ ASCII codes and Turbo Mode.
Control + ASCII Mode On - The scanner sends key combinations for ASCII control characters for values 00-1F. Refer to "Keyboard Function Relationships" on page 2-9 for CTRL+ ASCII Values. Default = Off
Control + ASCII Mode On
* Control + ASCII Mode Off
Turbo Mode - The scanner sends characters to an IBM AT terminal faster. (For use with IBM AT only.) If the terminal drops characters, do not use Turbo Mode. Default = Off
Turbo Mode On
* Turbo Mode Off
Numeric Keypad Mode - Sends numeric characters as if entered from a numeric keypad. Default = Off
Numeric Keypad Mode On
* Numeric Keypad Mode Off
Automatic Direct Connect - Use this selection if you are using a laptop whose keyboard is disabled when you plug in the scanner. This selection can also be used if you have an IBM AT style terminal and the system is dropping characters. After scanning these codes, you must re-boot your computer. Default = Off
Automatic Direct Connect Mode On
2-8
* Automatic Direct Connect Mode Off
Page 29
Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Full ASCII “CTRL” + 2 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] 6 -
2-9
Page 30
Communication Settings <Default All RS-232 Communication Settings>
Parity Parity provides a means of checking character bit patterns for validity. The Imager can be configured to operate under Mark, Space, Odd, Even, or No (None) parity options. The host terminal must be set up for the same parity as the Imager, to ensure reliable communication.
Mark
Space
Odd
Even
* None
2 - 10