The text of a manual · part 9 of 24
IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide: Symbologies, pages 80 to 88
Pages 80 to 88 of 216, from IMAGETEAM 4410/4710 2D Series Hand Held Imager User's Guide
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT4410 and HHP IT4710
Page 80
Linear Symbologies Interleaved 2 of 5, continued Check Digit When Check Digit is set to Validate, But Don’t Transmit, the unit will only read Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate, And Transmit, the scanner will only read Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data.
* No Check Digit
Validate, But Don’t Transmit
3 - 10
Validate, And Transmit
Page 81
Linear Symbologies IATA 2 of 5 < Default All IATA 2 of 5 Settings >
IATA 2 of 5
On
* Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3 - 11
Page 82
Linear Symbologies MSI < Default All MSI Settings >
MSI
On
* Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3 - 12
Page 83
Linear Symbologies MSI, continued Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
Transmit Check Digit
* Don’t Transmit Check Digit
3 - 13
Page 84
Linear Symbologies Code 93 < Default All Code 93 Settings >
Code 93
On
* Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3 - 14
Page 85
Linear Symbologies Code 128 < Default All Code 128 Settings >
Code 128
* On
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Maximum Message Length Message Length The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3 - 15
Page 86
Linear Symbologies ISBT Scan the On code below if you wish to decode ISBT bar codes. (ISBT codes are a combination of multiple linear symbols used to mark blood bags.)
On
3 - 16
* Off
Page 87
Linear Symbologies EAN/JAN 8 < Default All EAN/JAN 8 Settings >
EAN/JAN 8
On
* Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
Transmit Check Digit
* Don’t Transmit Check Digit
3 - 17
Page 88
Linear Symbologies EAN/JAN 8 Addenda You can add 2 or 5 digits to the end of all scanned EAN/JAN 8 data.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN 8 Addenda Required When Addenda Required is used, the scanner will only read EAN/JAN 8 bar codes that have addenda.
Required
* Not Required
EAN/JAN 8 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space.
Space
3 - 18
* No Space