Page 31

Communication Settings <Default All RS-232 Communication Settings>

Parity Parity provides a means of checking character bit patterns for validity. The Imager can be configured to operate under Mark, Space, Odd, Even, or No (None) parity options. The host terminal must be set up for the same parity as the Imager, to ensure reliable communication.

Mark

Space

Odd

Even

* None

2 - 11

Page 32

Baud Rate This sets the baud rate from 300 bits per second to 115,200 bits per second (see next page). Programming baud rate causes the data to be sent at the specified rate. The host terminal must be set to the same baud rate as the Imager to ensure reliable communication.

2 - 12

300

600

1200

2400

4800

9600

19200

* 38400

Page 33

Baud Rate, continued

57600

115200

Word Length Data Bits You can set the Word Length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications requiring use of the full ASCII set, select 8 data bits per character.

7 Data Bits

* 8 Data Bits

Word Length Stop Bits Word Length can be set to one or two stop bits.

* 1 Stop Bit

2 Stop Bits

2 - 13

Page 34

Hardware Flow Control When hardware flow control is on, the software checks for a CTS signal before sending data. This option is useful when your application supports the CTS signal.

On

* Off

Software Flow Control This allows control of data transmission from the Imager using software commands from the host device. When this feature is turned off, no data flow control is used. When Data Flow Control is turned on, the host device suspends transmission by sending the XOFF character (DC3, hex 13) to the Imager. To resume transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off when XOFF was sent.

On

2 - 14

* Off

Page 35

Serial Triggering This provides a means of sending a serial trigger command to start and stop decoding. When this feature is turned off, the Imager will not respond to serial trigger commands. When serial triggering is turned on, the Imager requires a serial trigger character to activate scanning and decoding. The unit continues to scan and decode bar codes until the Trigger Off character turns off the scanner, or a time out occurs. On the "Decimal to Hex to ASCII Conversion Chart" on page 2-34, find the hex characters you want to use to turn the trigger on and off. Locate the decimal values for those characters and scan the 2 digits for each one from the Programming Chart in the back of this manual.

When Serial Triggering is On, the default Trigger On decimal character is 18 (hex 12, DC2), and the default Trigger Off decimal character is 20 (hex 14, DC4).

On

* Off

Trigger On ‡

Trigger Off ‡

* Trigger Defaults

‡

A one to three digit decimal number and Save are required after reading this programming symbol. See "Decimal to Hex to ASCII Conversion Chart" on page 2-34, and the Programming Chart (inside back cover).

2 - 15

Page 36

Power Saving Mode This provides control of the Imager’s power consumption, as follows:

Low Power draws low LED current during image capture, allowing one read attempt only for each trigger pull. The Imager is less tolerant of hand movement during the read attempt, and powers down after the image capture is complete. Medium Power draws a normal LED current during image capture which enhances motion tolerance. Medium Power attempts to read as long as the trigger is pulled, going into a “doze” (low power) state after each read attempt. The Imager powers down ten seconds after the image capture is complete. Normal Power draws a normal LED current, attempting to read as long as the trigger is pulled. The Imager doesn’t go into a “doze” state after each read attempt, but may power down after two minutes if Power Hold Mode is turned Off.

Low Power

Medium Power

* Normal Power

Power Hold Mode Power Hold On keeps the Imager in a ready to read state. To conserve power, this selection may be turned Off and the unit will power down if not used within two minutes. When you are ready to use the Imager again, restore power by pressing the trigger.

On

2 - 16

* Off

Page 37

LED Power Level This selection allows you to adjust LED brightness.

Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting.

Off

Low

* High

LED Flashing If LED Flashing is turned off, the average current draw is increased and the aiming light won’t illuminate while the scanner reads a bar code.

Off †

†

* On

If LED Flashing is turned off, the average current draw is increased and the view finder won’t illuminate during the reading phase.

2 - 17

Page 38

Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken. Use these codes to set the time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over.

400 milliseconds

200 milliseconds

* Off (no delay)

Aimer Timeout Use this selection to set a timeout (in seconds) of the Imager’s aiming light when the device is not reading a bar code. Default setting = 60 seconds

Set Timeout ‡

‡

2 - 18

A one- to three digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).

Page 39

Aimer Interval Aimer Interval turns off the aiming light, or programs the aimer to come on at certain intervals when reading symbols with the scanner. You may program the scanner to use the aimer Every Read, Every Second Read, or Every Third Read. You may also program the scanner to use the aimer every “x” reads, by entering a number from 0 to 999 to indicate “x.”

Off

* Every Read

Every Second Read

Every Third Read

Every “x” Reads ‡

‡

A one- to three digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).

2 - 19

Page 40

AutoTrigger Two AutoTrigger Modes are available: Scan Stand and Presentation Mode. When a unit is in Scan Stand mode, the LED shines at the symbol on the base of the stand which tells it to remain idle. When a different code is presented, the Imager is triggered to read the new code. Presentation mode is for those applications where a scan stand will not work, i.e., when large packages must be scanned. To program the device for presentation mode, refer to "Presentation Mode" on page 2-21.

Scan Stand This selection programs the Imager to work in a Scan Stand.

* Off

On

Scan Stand LED Intensity This sets the idle LED intensity when the Imager is in Scan Stand mode. When a unit is in Scan Stand mode, the LED shines at the symbol on the base of the stand which tells it to remain idle. When a different code is presented, the Imager is triggered to read the new code. If the Imager has difficulty going back to reading the Scan Stand’s fixed code, for instance, in a low lighting situation, you may want to adjust the Scan Stand LED Intensity. A two digit number between 15 and 75 must be input after the Scan Stand LED Intensity programming code is scanned. A 15 corresponds to the lowest intensity level, and a 75 corresponds to the highest intensity level. 15 is the default setting. Note that when the unit is triggered to read a code, the unit uses the LED power level specified through "LED Power Level" on page 2-17.

Set Scan Stand LED Intensity

2 - 20