The text of a manual · part 6 of 23
IMAGETEAM 4400/4700 2D Series Hand Held Imager User's Guide: Programming, pages 41 to 50
Pages 41 to 50 of 182, from IMAGETEAM 4400/4700 2D Series Hand Held Imager User's Guide
The original document is the PDF (3.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT4400
Page 41
Scan Stand Lights You can turn off the scanner light when the imager is in idle mode in a scan stand.
Off
* On
Presentation Mode This programs the scanner to work in Presentation Mode. Default = Off.
* Off
On
Presentation Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads at POS (point of sale). Use shorter delays in applications where repetitive bar code scanning is required. Entries are in milliseconds, up to 10,000. Default = 500.
Presentation Reread Delay
Presentation Default Defaults all presentation mode settings. Defaults = Presentation Mode Off, Presentation Reread Delay 500 ms (1/2 sec.), Presentation Aimer On.
Presentation Default
2 - 21
Page 42
Presentation Aimer You can turn on or off the scanner’s aiming light when the device is not reading a bar code.
Off
* On
Zoom Use Zoom to zoom in and read smaller matrix codes. The zoom selection does not affect reading of linear bar codes. The factory default setting is Off. (High Density scanners are programmed with the zoom turned on when shipped from the factory. If you scan the LR Factory Default Settings code on page 2-2, the zoom will be turned off.)
On
2 - 22
* Off
Page 43
Zoom Placement This lets you position the read area (crosshairs) of the Imager when it is in zoom mode. The Zoom Vertical moves the crosshairs vertically, and the Zoom Horizontal move them horizontally, as illustrated below:
Note: When zoom is turned on, the field of view of the Imager is reduced, making it more difficult for the Imager to read large matrix symbols.
Zoom Vertical
Zoom Horizontal 3 4 5 6 3 4 5 6
After the Zoom Placement code below is scanned, you must scan a 1 digit code (inside back cover) to enter the zoom position you want. The default for both vertical and horizontal placement is 4, which centers the crosshairs in the field of view.
Zoom Vertical
Zoom Horizontal
Note: The default setting for the HD Imager is a Zoom Vertical of 6 and, for the HD10, the default setting is a Zoom Vertical of 5.
2 - 23
Page 44
Beeper Volume
Off
Low
Medium
* High
Power Up Beeper
* On
Off
Output Sequence Beeper If you are using an Output Sequence (see "Output Sequence Overview" on page 2-41), you may want to hear a beep after each bar code as it is read. Scan Output Sequence Beeper On to enable this feature, or Off to disable it.
* On
2 - 24
Off
Page 45
Beep On Decode If you want the scanner to beep each time it reads a bar code, leave this setting On. If you don’t want it to beep on each read, but do want it to beep for other events, set this selection to Off.
Off
* On
Beeper Default Defaults all beeper settings. Defaults = Beeper Volume High, Power Up Beeper On, Output Sequence Beeper On, Beep On Read On.
Beeper Default
2 - 25
Page 46
Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, which increases data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each).
Intercharacter Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each character of scanned data. You can program up to 99 steps (of 5 ms each). Scan the Intercharacter Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again. Prefix
Scanned Data 1
2
3
4
Suffix 5
Intercharacter Delay
Intercharacter Delay To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover.
2 - 26
Page 47
Interfunction Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each segment of the message string. You can program up to 99 steps (of 5 ms each). Scan the Interfunction Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again. Prefix STX
1
Scanned Data HT
2 3 4 5
Suffix CR
LF
Interfunction Delays
Interfunction Delay To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover.
2 - 27
Page 48
Intermessage Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between each scan transmission. You can program up to 99 steps (of 5 ms each). Scan the Intermessage Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover and scan the correct digits and Save again.
1st Scan Transmission
2nd Scan Transmission
Intermessage Delay
Intermessage Delay To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover.
2 - 28
Page 49
Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string:
Prefix 1-10 alpha numeric characters
Scanned Data variable length
Suffix 1-10 alpha numeric characters
Points to Keep In Mind • It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the "Decimal to Hex to ASCII Conversion Chart" on page 2-34, plus Code I.D. and Aim I.D. • You can string together several entries for several symbologies at one time. • Enter prefixes and suffixes in the order in which you want them to appear on the output.
2 - 29
Page 50
Adding a Prefix or Suffix 1. Scan the Add Prefix (page 2-32) or Add Suffix symbol (page 2-32). 2. Determine the 2 digit Hex value from the "Symbology Chart "on page 2-33 for the symbology to which you want to apply the prefix or suffix. 3. Scan the 2 hex digits from the Programming Chart inside the back cover or scan 9, 9 for all symbologies. 4. Determine the hex value from the "Symbology Chart "on page 2-33 for the prefix or suffix you wish to enter. 5. Scan the 2 digit hex value from the Programming Chart inside the back cover.
Note: Repeat Steps 4 and 5 for every prefix or suffix character. Note: To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C. 6. Scan Save to exit and save, or scan Discard to exit without saving. Repeat Steps 1-6 to add a prefix or suffix for another symbology. Example: Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for UPC only: 1. Scan Add Suffix. 2. Determine the 2 digit hex value from the "Symbology Chart" on page 2-33 for UPC. 3. Scan 6, 3 from the Programming Chart (inside back cover). 4. Determine the hex value from the "Decimal to Hex to ASCII Conversion Chart" on page 2-34 for the CR (carriage return). 5. Scan 0, D from the Programming Chart (inside back cover). 6. Scan Save, or scan Discard to exit without saving.
Clearing One or All Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. 1. Scan the Clear One Prefix or symbol. 2. Determine the 2 digit Hex value from the "Symbology Chart "on page 2-33 for the symbology from which you want to clear the prefix or suffix. 3. Scan the 2 digit hex value from the Programming Chart inside the back cover or scan 9, 9 for all symbologies. Your change is automatically saved.
2 - 30