Page 21

2 Programming

Introduction Use this section to program the hand-held Imager. This programming section contains the following menuing selections: • General Selections • Terminal Interface Selections • Keyboard Selections • Communication Settings • Imager Selections • Output Selections • Prefix/Suffix Selections • Data Formatter Selections • Output Sequence Selections

2-1

Page 22

Reset Factory Settings All operating parameters are stored in nonvolatile memory resident in the Imager, where they are permanently retained in the event of a power interruption. When you receive your Imager, certain operating parameters have already been set. These are the factory defaults, indicated by the symbol “✱” on the programming menu pages (beneath the default programming symbol). Default charts begin on page 5-1. Depending on your model, scan one of the following bar codes to set the imager to the original factory settings, clearing any programming changes you may have made.

HD

HD10

LR

Status Check Read the Show Software Revision symbol to transmit the software revision level to the host terminal. The software revision will be printed out as “REV_SW:$ProjectRevision:1.xx$;REV_WA:31204734-xxx.” Read the Show Data Formats symbol to transmit the existing Data Format Editor formats. One format per line will be printed out.

Show Software Revision

2-2

Show Data Formats

Page 23

All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code.

All Symbologies On

All Symbologies Off

Revision Selections Both the following programming codes would not normally be needed unless you have a problem with the unit. An Application Support Representative may request the boot code or power PC revision information in order to trouble shoot a problem.

Power PC Revision

Boot Code Revision

2-3

Page 24

Terminal Interface IMAGETEAM 4400 and 4700 scanners are factory programmed for a keyboard wedge interface to an IBM PC AT with a USA keyboard. If this is your interface and you do not need to modify the settings, skip to page 2-16 for Imager Selections. If your interface is not a standard PC AT, refer to the "Supported Terminals Chart" on page 2-5 and locate the Terminal ID number for your PC. Scan the Terminal ID bar code below, then scan the numeric bar code(s) on the inside back cover of this manual to program the scanner for your terminal ID. Scan Save to save your selection. For example, an IBM PS/2 terminal has a Terminal ID of 002. You would scan the Terminal ID bar code, then 0, 0, 2 from the inside back cover, then Save. If you make an error while scanning the digits (before scanning Save), scan the Discard code on the back cover and scan the digits and the Save code again.

Factory Default = 03

Terminal ID

2-4

Save

Page 25

Supported Terminals Chart Terminal

Model(s)

Terminal I.D.

DEC DELL DTK Fujitsu

PC433 SE (Portable PC) Latitude (Portable PC) 486 SLC (Portable PC) Stylistic (Portable PC)

003 003 003 003

HHLC (Code 128 Emulation) IBM IBM IBM IBM IBM IBM IBM Midwest Mitak Olivetti Olivetti Reliasys RS-232 TTL Televideo Texas Instruments Toshiba Toshiba Zenith

PC X PS/2 25, 30, 77DX2 AT, PS/2 30-286, 50, 55SX, 60, 70, 003, 70-061, 70-121, 80 AT Compatibles Keyboard Emulation (Non-wedge) Thinkpad 360 CSE, 34, 750 (Portable PC) Thinkpad 365, 755 CV (Portable PC) AT Thinkpad Micro Elite TS 30 PS (Portable PC) 4022 (Portable PC) M19, M24, M28, M200 M240, M250, M290, M380, P500 TR 175 990, 995, 9060 Extensa 560CD (Portable PC) 2600 (Portable PC) Satellite T1960, T2130, CS (Portable PC) Z-note (Portable PC)

089* 001 002

003 097 003 106 003 003 001 003 003 000 002 003 003 003 003

* This capability is not available for the IT4700. Contact the factory if this capability is needed for the IT4700.

Note: These interfaces are available only for units that have 1 megabyte of program memory. The software revision indicates the memory size. If you are not certain of your unit’s memory, please contact Welch Allyn’s Application Support (see page 10-5).

2-5

Page 26

Keyboard Country Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from the inside back cover, then the Save bar code to program the keyboard for your country. As a general rule, the following characters are not supported by the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~

Keyboard Country

Country Code Scan Belgium..................... 1 Denmark ................... 8 Finland...................... 2 France ...................... 3 Germany/Austria....... 4 Great Britain ............. 7

Country Code Scan Italy ........................5 Norway...................9 Spain......................10 Switzerland ............6 USA (Default) .........0

Save

2-6

Page 27

Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. Default = Regular.

Regular is used when you normally have the Caps Lock key off. Caps Lock is used when you normally have the Caps Lock key on. Shift Lock is used when you normally have the Shift Lock key on. (Not common to U.S. keyboards.) Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED which notes the Caps Lock status. Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent), but should not be used for laptops. To connect the scanner to a laptop, use "Automatic Direct Connect Mode On"on page 2-8.

* Regular

Caps Lock

Shift Lock

Automatic Caps Lock

Emulate External Keyboard

2-7

Page 28

Keyboard Modifiers This modifies special keyboard features, such as CTRL+ ASCII codes and Turbo Mode.

Control + ASCII Mode On - The scanner sends key combinations for ASCII control characters for values 00-1F. Refer to "Keyboard Function Relationships" on page 2-9 for CTRL+ ASCII Values. Default = Off

Control + ASCII Mode On

* Control + ASCII Mode Off

Turbo Mode - The scanner sends characters to an IBM AT terminal faster. (For use with IBM AT only.) If the terminal drops characters, do not use Turbo Mode. Default = Off

Turbo Mode On

* Turbo Mode Off

Numeric Keypad Mode - Sends numeric characters as if entered from a numeric keypad. Default = Off

Numeric Keypad Mode On

* Numeric Keypad Mode Off

Automatic Direct Connect - Use this selection if you are using a laptop whose keyboard is disabled when you plug in the scanner. This selection can also be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off

Automatic Direct Connect Mode On

2-8

* Automatic Direct Connect Mode Off

Page 29

Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Full ASCII “CTRL” + 2 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] 6 -

2-9

Page 30

Connecting the Scanner to a Serial Port 6. Turn off power to the terminal/computer. 7. Connect the interface cable to the scanner. 8. Connect the interface cable to the 5 or 14 VDC power supply and plug in the power supply. The scanner will beep twice. 9. Connect the interface cable to the terminal/computer.

Power Supply

2 3

Interface Cable

1

10. Turn the terminal/computer power back on. 11. Verify the scanner operation by scanning a bar code from the back cover of this manual. The scanner will beep once. The scanner is now connected and ready to communicate with your terminal/PC. Turn to "Communication Settings" on page 2-11 to program the communication parameters for a serial interface.

2 - 10