Page 51

4 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string:

Prefix 1-10 alpha numeric characters

Scanned Data variable length

Suffix 1-10 alpha numeric characters

Points to Keep In Mind • It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the ASCII chart (page 4-6 ), plus Code I.D. and Aim I.D. • You can string together several entries for several symbologies at one time. • Enter prefixes and suffixes in the order in which you want them to appear on the output.

4-1

Page 52

To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-4). Step 2. Determine the 2 digit Hex value from the Symbology Chart (page 4-5) for the symbology to which you want to apply the prefix or suffix. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover or scan 9, 9 for all symbologies. Step 4. Determine the hex value from the Decimal to Hex to ASCII Conversion Chart (page 4-6) for the prefix or suffix you wish to enter. Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover. Step 6. Repeat Steps 4 and 5 for every prefix or suffix character. Step 7. To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C. Step 8. Scan Save to exit and save, or scan Discard to exit without saving. Repeat Steps 1-6 to add a prefix or suffix for another symbology.

Example: Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for UPC only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Chart (page 4-5) for UPC. Step 3. Scan 6, 3 from the Programming Chart (inside back cover). Step 4. Determine the hex value from the Decimal to Hex to ASCII Conversion Chart (page 4-6) for the CR (carriage return). Step 5. Scan 0, D from the Programming Chart (inside back cover). Step 6. Scan Save, or scan Discard to exit without saving.

4-2

Page 53

To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (page 4-5) for the symbology from which you want to clear the prefix or suffix. Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover or scan 9, 9 for all symbologies. Your change is automatically saved.

To Add a Carriage Return Suffix to all Symbologies Scan the following bar code if you wish to add a Carriage Return Suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.

Add CR Suffix All Symbologies

4-3

Page 54

Prefix Selections

Add Prefix

Clear One Prefix

Clear All Prefixes

Suffix Selections

Add Suffix

Clear One Suffix

Clear All Suffixes

Save

Discard

4-4

Page 55

Symbology Chart Symbology

Code AIM ID ID

Hex ID

Symbology

Code AIM ID ID

Hex ID

China Postal q

]X0

71

Interleaved 2 of 5 e

]l0

65

Codabar a

]F0

61

Matrix 2 of 5 m

]X0

6D

Code 2 of 5 f

]S0

66

MicroPDF417

R

]L0

52

Code 11 h

]H0

68

MSI g

]M0

67

Code 39 b

]A0

62

PDF417 r

]L0

72

Code 39 PARAF w

]X0

77

Plessey n

]P0

6E

Code 93 i

]G0

69

RSS-14 y

]e0

79

Code 128 j

]C0

6A

Telepen t

]B0

74

UPC c

]E0

EAN/JAN d

]E0

64

EAN•UCC Composite y

]e0

79

IATA 2 of 5 f

]R0

66

All Symbologies †

63 99

Note: Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. † All Symbologies: Prefix/Suffix programming only!

4-5

Page 56

Decimal to Hex to ASCII Conversion Chart Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

SP ! “ # $ % & ‘ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

@ A B C D E F G H l J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

‘ a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL

4-6

Page 57

Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Section 10, Supported Interface Keys. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.

* Enable

Disable

Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each).

4-7

Page 58

Intercharacter Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each character of scanned data. You can program up to 99 steps (of 5 ms each). Scan the Intercharacter Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Intercharacter Delay bar code, scan the correct digits, and Save again. Prefix

Scanned Data 1

2

3

4

Suffix 5

Intercharacter Delay

Intercharacter Delay To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover.

4-8

Page 59

User Specified Intercharacter Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed after the transmission of a particular character of scanned data. You can program up to 99 steps (of 5 ms each) to follow the character you specify. Scan the Delay Length bar code below, then the number of steps for the delay, and the SAVE bar code from the inside back cover. Next, scan the Character to Trigger Delay bar code, then the 2 digit hex value for the ASCII character that will trigger the delay (refer to the Decimal to Hex to ASCII conversion chart on page 4-5). Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the inside back cover, scan the Character to Trigger Delay bar code, scan the correct digits, and Save again.

Delay Length

Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of steps to 00. Scan the SAVE bar code from the inside back cover.

4-9

Page 60

Interfunction Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each segment of the message string. You can program up to 99 steps (of 5 ms each). Scan the Interfunction Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the inside back cover, scan the Interfunction Delay bar code, scan the correct digits, and Save again. Prefix STX

1

Scanned Data HT

2 3 4 5

Suffix CR

LF

Interfunction Delays

Interfunction Delay To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover.

Intermessage Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between each scan transmission. You can program up to 99 steps (of 5 ms each). Scan the Intermessage Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the inside back cover, scan the Intermessage Delay bar code, scan the correct digits, and Save again.

1st Scan Transmission 2nd Scan Transmission Intermessage Delay

Intermessage Delay To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover.

4 - 10