Page 13

1 Getting Started The IMAGETEAM™ (IT) 3800 is a high performance linear imaging scanner from HHP. The IT3800 marks a new performance level for hand held scanners. Linear imaging technology is defined by a bright and sharply focused aiming line, high resolution imaging, and fast reading speed. The IT3800 is comfortable to hold, easy to use, rugged, and excellent for all general scanning applications. The IMAGETEAM™ (IT) 3900 is a fixed mount bar code scanner designed for retail kiosks, manufacturing WIP tracking, document processing, or other OEM applications. It is a complete decoded output scanner that is easy to integrate. It communicates with PCs or host terminals via keyboard wedge or a serial RS232 interface. The IT3900 can be used internally or externally. The housing provides protection from dust, dirt, and electrostatic discharge.

Typical Applications for the IT3900 The IT3900 is an ideal scanner for retail kiosks. The bright aiming line and large working range make scanning easy for untrained users. The IT3900 mounted in a stand makes an efficient bar code document reader; it takes up a minimum of counter space and reads and transmits data quickly.

About This Manual This User’s Guide provides installation and programming instructions for the IMAGETEAM 3800/3900. Product specifications, dimensions, warranty, and customer support information are also included. HHP’s bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. An asterisk (*) next to an option indicates the default setting.

1-1

Page 14

Unpacking the Scanner Open the carton. The shipping carton or container should contain: An IMAGETEAM 3800:

or an IMAGETEAM 3900:

• Check to make sure everything you ordered is present. • Save the shipping container for later storage or shipping. • Check for damage during shipment. Report damage immediately to the carrier who delivered the carton.

1-2

Page 15

IT3800 Scanner Identification

IT3900 Scanner Identification IT3900 Scanner Bottom View

1-3

Page 16

Connecting the Scanner When Powered by Host (Keyboard Wedge) A scanner can be connected between the keyboard and PC as a “keyboard wedge,” plugged into the serial port, or connected to a portable data terminal in wand emulation or non decoded output mode. The following is an example of a keyboard wedge connection: 1. Turn off power to the terminal/computer. 2. Disconnect the keyboard cable from the back of the terminal/computer.

Disconnect

3. Connect the appropriate interface cable to the scanner and to the terminal/computer.

3

1

2

4. Turn the terminal/computer power back on. The scanner will beep twice. 5. Verify the scanner operation by scanning a bar code from the back cover of this manual. The scanner will beep once.

1-4

Page 17

2.99

Cable Exit

47.5˚

.89

1.52

.700

.700

2.67

M4 Inserts typ 3 Thread depth 4.7 mm (.185")

.04

B

Note: Measurements are in inches.

Aperture plane 4.64

.65

1.3

5 6 7 8.5

5 mil

9.5

13 mil

TYPICAL PERFORMANCE ON HIGH QUALITY SYMBOLS.

4.1

3.5 (5 mil and 7.5 mil)

3 mil

7.5 mil

.8 Optical center is ± 2" from horizontal. (Angle begins at aperture plane.)

2.5 (13 mil and 15 mil)

1.52 Ref

1.52

1.9

15 mil

3

2˚ Ref typ

4.2

4.9

23˚ typ

Mounting Information for the IMAGETEAM 3900

1-5

Page 18

Mounting Information, continued Specular Zone The IT3900 must be mounted at a 5 degree, or greater, angle to the bar code in order to scan properly:

The scanner is now connected and ready to communicate with your terminal/ PC. You must program the scanner for your interface before bar code data can be transmitted to your terminal/PC. If you are using the scanner as a keyboard wedge, turn to page 2-1. If the scanner is connected via a serial port, turn to page 2-9. If this is a wand emulation application, turn to page 2-16, and for a non decoded output connection, turn to page 6-2.

Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces.

Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.

1-6

Page 19

The most common interface is Keyboard Wedge. The following Keyboard Wedge bar code also programs a carriage return (CR) suffix.

Keyboard Wedge Interface for IBM PC AT and Compatibles

The following Plug and Play bar code for IBM XT and Compatibles also programs a carriage return (CR) suffix.

IBM XT and Compatibles The following Plug and Play bar code for IBM PS-2 and Compatibles also programs a carriage return (CR) suffix.

IBM PS-2 and Compatibles Use Non Decoded Output Laser Emulation when connecting to a secondary terminal with integral decoding. This also sets the transmission rate to 36 scans per second and the polarity to white high.

Non Decoded Output Laser Emulation For most laptops, scanning the Laptop Direct Connect bar code allows operation of the integral keyboard. The following Laptop Direct Connect bar code also programs a carriage return (CR) suffix.

Laptop Direct Connect

1-7

Page 20

The RS-232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS-232 Interface bar code adds a suffix of a CR and LF, and also programs the parameters: Option

Setting

Baud Rate

9600 bps

Parity

Even

Data Format

7 data bits, parity bit, 1 stop bit (8 bit data)

RS-232 Interface In Wand Emulation mode, the scanner decodes the bar code then sends data in the same format as a wand scanner. The Same Code format transmits UPC, EAN, Code 128 and Interleaved 2 of 5 bar codes without any changes, but converts all other symbologies to Code 39.

Wand Emulation Same Code The following Wand Emulation bar code sets the interface to Wand Emulation mode and translates bar code data as Code 39 symbology. It also programs the Transmission Rate to 25 inches per second, and Output Polarity to black high.

Wand Emulation (Code 39 Format)

Note: For the 3800PDF model: When the 3800PDF interface is set to wand emulation, all PDF417 bar code data is transmitted as Code 128. Data from other symbologies follow the rules described above.

1-8

Page 21

IBM 4683 Ports 5B, 9B, and 17 Interface Note: The following Retail “Plug and Play” codes are for use with the 3800LR11 and 3800LR-15 models only. Scan one of the following “Plug and Play” codes to program the IT3800 for IBM 4683 Port 5B, 9B, or 17.

Note: After scanning one of these codes, you must re-boot the cash register.

IBM 4683 Port 5B Interface (Default for -11 Models)

IBM 4683 Port 9B HHBCR-1 Interface

IBM 4683 Port 9B HHBCR-2 Interface

IBM 4683 Port 17 Interface

Each bar code above also programs the following suffixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E Code 39 Interleaved 2 of 5 Code 128

Suffix 0C 16 0D 0A 00 0A 0B 00 0D 0B 00 18 0B

1-9

Page 22

USB Interface Note: The following USB “Plug and Play” codes (IBM SurePOS Hand Held and Tabletop Scanners) are for use with the 3800LX-15 model only. Scan one of the following “Plug and Play” codes to program the IT3800 for IBM SurePos (USB Hand Held scanner) or IBM SurePos (USB Tabletop scanner).

Note: After scanning one of these codes, you must re-boot the cash register.

IBM SurePos (USB Hand Held Scanner) Interface

IBM SurePos (USB Tabletop Scanner) Interface Each bar code above also programs the following suffixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E Code 39 Interleaved 2 of 5 Code 128

1 - 10

Suffix 0C 16 0D 0A 00 0A 0B 00 0D 0B 00 18 0B

Page 23

Note: The following USB “Plug and Play” codes (USB Keyboard - PC , USB Keyboard - Mac, and USB HID) are for use with the 3800LX-14 and 3800LX-15 models. Scan one of the following codes to program the IT3800 for USB PC Keyboard or USB Macintosh Keyboard. Default = USB Keyboard (PC).

* USB Keyboard (PC)

USB Keyboard (Mac) Scan the following code to program the IT3800 for USB HID bar code scanners.

USB HID Bar Code Scanner

USB Converter Note: The USB converter is for use with the 3800-11 and 3800/3900-12 models only. The IT3800-11, -12 and IT3900-12 models use a USB converter to simulate a USB keyboard. Data flows into applications as if entered from the keyboard. The USB converter is compatible with Apple iMac Series and Windows®98 and later PCs. Use cable set 42206062-01 to make the USB port connection. To set up the USB communications, find the terminal ID in the Supported Terminal Chart on page 2-3, and follow the instructions on page 2-2. The PC and scanner automatically connect. Communications start immediately.

1 - 11

Page 24

OCIA Interface Note: The OCIA interfaces are only available on the 3800LR-11 model. Scan one of the following “Plug and Play” codes to program the IT3800 for Generic OCIA, NCR OCIA Short Format (8 bit), NCR OCIA Long Format (9 bit), and Nixdorf OCIA.

Note: After scanning one of these codes, you must re-boot the cash register.

Generic OCIA Interface The Generic OCIA bar code also programs the following prefixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E

Prefix 06 06 06 01 05

NCR OCIA Short Format (8 Bit) Interface

NCR OCIA Short Format (8 Bit) Interface The NCR OCIA Short Format (8 Bit) bar code also programs the following prefixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E

1 - 12

Prefix 0F 0F 0F 0A 0E

Page 25

NCR OCIA Long Format (9 Bit) Interface

NCR OCIA Long Format (9 Bit) Interface The NCR OCIA Long Format (9 Bit) bar code also programs the following prefixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E Code 39 Interleaved 2 of 5 Code 128

Prefix 46 46 46 41 45 42 31 42 32 42 33

Nixdorf OCIA Interface

Nixdorf OCIA Interface The Nixdorf OCIA bar code also programs the following prefixes for each symbology: Symbology EAN/UPC with Addenda Code 39 Interleaved 2 of 5 2 of 5 Code 128

Prefix 44 4B 44 49 44 48 44 47 44 4A

1 - 13

Page 26

Serial Wedge The IT3800/3900 uses true and TTL signal levels to wedge into an RS-232 serial network. Use IT3800/3900 serial wedge cables only to prevent damage to the scanner. Refer to the serial interface programming (pages 2-9 to 2-13) to set the baud rate and communications protocol. To set up the serial wedge terminal ID, find the terminal ID in the Supported Terminal Chart and follow the instructions on page 2-2. Set the port to which you want the scanned data to transmit. Port 1 corresponds to P1 on the output cable and Port 2 corresponds to P2 on the output cable. Choosing Both sends scanned data to P1 and P2. Default = P1.

* P1

P2

Both P1 and P2

1 - 14