Page 91
Telepen, continued EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the 2-digit value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-60. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum (Default =1)
Maximum (Default =60)
7 - 21
Page 92
UPC A <Default All UPC A Settings>
UPC A
* On
Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
* On
Off
Number System The numeric system digit of a UPC symbol is normally transmitted, but the unit can be programmed so it will not transmit it. Default = On.
* On
Off
7 - 22
Page 93
UPC A, continued Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data. Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
Addenda Required When Addenda Required is set to on, the scanner will only read UPC A bar codes that have addenda. Default = Off.
On
* Off
7 - 23
Page 94
UPC A, continued Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On.
* On
Off
UPC Strict Decoding When UPC Strict Decoding is used, the scanner only reads bar codes that are close to spec. This reduces the number of misreads, but also reduces the tolerance for bar codes that are slightly out of spec.
On
* Off
7 - 24
Page 95
UPC E <Default All UPC E Settings>
UPC E0 and UPC E1 Most UPC bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes that lead with the 1 number system, use the UPC E1 selection. Default = On (UPC E0) and Off (UPC E1).
* UPC E0 On
UPC E0 Off
UPC E1 On
* UPC E1 Off
UPC E Expand UPC E Expand expands the UPC E code to the 12 digit, UPC A format. Default = Off.
On
* Off
7 - 25
Page 96
UPC E, continued Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
* On
Off
Number System The numeric system digit of a UPC symbol is normally transmitted, but the unit can be programmed so it will not transmit it. Default = On.
* On
Off
7 - 26
Page 97
UPC E, continued Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data. Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
Addenda Required When Addenda Required is set to on, the scanner will only read UPC E bar codes that have addenda. Default = Off.
On
* Off
7 - 27
Page 98
UPC E, continued Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On.
* On
Off
7 - 28
Page 99
EAN/JAN 13 <Default All EAN/JAN Settings>
EAN/JAN 13
* On
Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
* On
Off
7 - 29
Page 100
EAN/JAN 13, continued Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data. Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar codes that have addenda. Default = Off.
On
* Off
7 - 30