The text of a manual · part 5 of 10
Image Kiosk/WinCE 5.0 Power Tools User's Guide, pages 41 to 50
Pages 41 to 50 of 94
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IK8560 and HHP IK8570
Page 41
If there is more than one bar code in the package, EZConfig Client decodes the bar code, records that one bar code has been read, and waits for the next scan.
5. Scan all the bar codes in the package. Bar codes can be scanned in any order. 6. When all bar codes in the package have been scanned, the EZConfig Client deploys the data.
Configuration File Processing After decoding, EZConfig Client saves all configuration files to the location on the IK8560/8570 selected in the Remote Path (page 2-18) field on the Bar Codes Tab (page 2-18). (If the Temporary, page 2-20, option is selected in the bar code, EZConfig Client does not save the configuration file.) There are two types of configuration files: configuration documents and registry documents. EZConfig Client processes each type of configuration file differently. Configuration Documents If the configuration file was associated with an application, EZConfig Client launches and deploys the data to that application for processing.
Note:
Registry Documents
DeviceConfig.exm file is a configuration document that must be associated with DeviceConfig.exe to be processed appropriately. After decoding the bar code, EZConfig Client deploys the data to DeviceConfig.exe, which applies the settings to the IK8560/8570.
Registry documents are always associated with EZConfig Client. The Execute option (Execute, page 2-13) determines whether the registry is updated or not. If Execute is selected, EZConfig Client updates the registry immediately after decoding the bar code.
Multiple Bar Codes Some configuration files generate more than one bar code. If multiple bar codes were generated, EZConfig Client recognizes that there is more than one bar code in the package and tracks each bar code scanned and decoded. Bar codes can be scanned in any order, but EZConfig Client does not deploy the data until all the bar codes in the package have been scanned.
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
2 - 27
Page 42
EZConfig Client Window
Field
Description
Package ID
This is the ID of the entire package. EZConfig Editor assigns an ID to bar code packages when creating the bar code.
Status
This field displays the decode status of the bar codes scanned so far. If there is more than one bar code in the package, this field acts as a decode counter. The Status field displays: • How many bar codes have been scanned and • How many bar codes are in the package
Read # box
This box displays the list of bar codes scanned and decoded.
Accept Unsecure
This option allows EZConfig Client to scan bar codes that are not encrypted. Note: By default, all bar codes created in EZConfig Editor are encrypted.
Command Line Arguments /%filename
Executes the configuration file; this is the default entry.
/q
Quiet mode
/s
Full screen
/o
No menu
/e
Exit if first scan fails to deliver a valid bar code
/u
Accept (decode) unsecure bar codes
2 - 28
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 43
3 DeviceConfig
Overview DeviceConfig consists of • The DeviceConfig executable file located in the \Program Files\Power Tools folder, and the • The DeviceConfig.exm file located in the \IPSM folder.
DeviceConfig.exe
DeviceConfig.exm
DeviceConfig.exe looks for and applies the settings in the DeviceConfig.exm file.
DeviceConfig.exm The DeviceConfig.exm file contains terminal configuration settings and is stored in the \IPSM folder. As such, the configuration settings in this file persist through cold boots and should be considered system defaults. For example, if you use the DeviceConfig.exm file to set up a radio, those settings remain in the IK8560/8570 after the next cold boot.
Autorun The Autorun Configuration File (see page 4-1) launches DeviceConfig.exe during startup, which means that DeviceConfig.exe applies the (enabled) settings in the \IPSM\DeviceConfig.exm file after each cold boot.
Control Panel Applets Many settings in the DeviceConfig.exm file, such as Connection settings, have Control Panel applets with GUIs on which the user can enter and save new values. If a user changes a setting in the Control Panel applet, that setting is applied but stored in RAM memory and erased during the next cold boot. Then, as part of startup after the next cold boot, Autorun launches DeviceConfig.exe, which then re-applies the settings in the DeviceConfig.exm file.
Bar Code Delivery When the DeviceConfig.exm file is delivered to the IK8560/8570 via bar code, EZConfig Client launches DeviceConfig.exe automatically after decoding. DeviceConfig.exe then applies the settings in theDeviceConfig.exm file in the IK8560/8570. For more information, see Creating Bar Codes (page 2-16) and EZConfig Client (page 2-26). Requirements The DeviceConfig.exm file must be associated with DeviceConfig.exe for EZConfig Client to launch DeviceConfig.exe after decoding the bar code. In EZConfig Editor, the associated application path must be \Program files\Power Tools\deviceconfig.exe For more information, see Associating Applications, page 2-13.
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
3-1
Page 44
DeviceConfig Sections and Keys The sections and keys in the DeviceConfig.exm file are locked, which means that you can change the value but not the name or description. The description of locked keys contains “[Locked]” next to the name. Section Name
Description
See Page
Connections
Configures ActiveSync settings.
3-2
System
Configures basic system settings.
3-2
Applications
Configures software applications.
3-2
Connections Section The Connections section contains child sections that set communication parameters on the IK8560/8570. Key
Description
Default Value
Available Values
ActiveSync
Enable/Disable automatic connection when the device is connected via USB to a PC. If set to 1, a connection will automatically be established.
1
0=Disabled 1=Enabled
System Section The System section contains child sections that configure various system settings. For specifics on each section and its keys, refer to the Description sections in the DeviceConfig.exm file itself.
Applications Section The Applications section configures specific software applications installed on the IK8560/8570.
Internet Explorer Section The Internet Explorer section defines the home page for Internet Explorer 6.0 for Microsoft Windows CE.
Command Line Arguments /q
Quits the program; this command line in the Args field of the Associated Application window stops the confirmation message from appearing after DeviceConfig.exe finishes processing.
Launching DeviceConfig.exe Manually DeviceConfig.exe does launch automatically after each cold boot. However, if you make changes to the DeviceConfig.exm file that you want applied in the IK8560/8570 immediately, manually launch DeviceConfig.exe. 1. Tap Start > Run, browse to \Program Files\Power Tools\ and double tap DeviceConfig.exe, then tap OK. Device Config executes and any changes the user might have made to DeviceConfig.exm are applied.
3-2
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 45
2. Tap Tools > Launch Associated App.
3. The settings in the DeviceConfig.exm file are saved and applied to the IK8560/8570 configuration by DeviceConfig.exe.
Temporary Option for Bar Code Deployment The Bar Codes Tab (see page 2-18) in EZConfig Editor contains a Temporary option (see page 2-20) that, when selected during bar code creation, applies the settings in the DeviceConfig.exm file temporarily, which means until the next cold boot. In the IK8560/8570, EZConfig Client deploys the DeviceConfig.exm file and launches DeviceConfig.exe, which applies the settings in the DeviceConfig.exm file as usual. However, when the Temporary option is selected, the DeviceConfig.exm file is not saved after processing is finished. The original file is preserved instead, and its settings will be restored during/upon the next cold boot. Select this option when you want a temporary configuration in the IK8560/8570 (such as access to a specific network in a facility) without changing the default configuration.
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
3-3
Page 46
3-4
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 47
4 Startup Power Tools
Overview Startup is the launch sequence when an IK8560/8570 is booted. There are two startup Power Tools: 1. Autorun, page 4-1 2. AutoInstall, page 4-5
Autorun Autorun specifies the software applications to launch after each hard reset. Autorun is located in the \IPSM folder and consists of an Autorun.exe that is programmed by the Autorun Configuration File (page 4-1) .
During startup, after a soft or hard reset, the IK8560/8570 operating system looks for and launches \IPSM\Autorun.exe. If the Autorun.exe is configured (by Autorun.exm) to launch an application, that application launches when Autorun.exe launches. Autorun can launch up to 32 applications or utility programs after each hard reset.
Note: The Autorun.exm file allows applications to be launched based on conditional situations, including the return code of another application launched previously and specific characteristics of the IK8560/8570 itself.
Autorun Configuration File The Autorun.exm file has a multi-level tree structure. There are two top levels: Section Name
Description
See Page
Settings
Stores general Autorun settings
4-2
Programs
Determines which programs to launch; this section has multiple child sections
4-3
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
4-1
Page 48
Settings Section
Key
Function
Default
Available Values
Version
Stores the .exm file version.
22
You cannot modify this value!
StartMenu
Enables and Disables the StartMenu during the Autorun execution.
1
0=Disables 1=Enable
Debug
Controls the debug function at AutoInstall.
0
0=Disable 1=Enable, an autorun.log file is created in the \IPSM folder.
TestMode
Runs the IK8560/8570 in test mode and tests the functionality of AutoInstall. This is a diagnostic tool. When enabled, applications stored in the AutoInstall folder, including the radio drivers, are not loaded during startup.
0
0=Disable 1=Enable
Note: This section and most of its keys are locked, which means that you can change the value but not the name or description.
4-2
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 49
Programs Section The Programs section determines which programs launch at startup.
Program Sections and Launch Sequence Each section is a program to launch at startup. The sequence of sections determines the launch sequence on the IK8560/8570; the IK8560/8570 reads this file consecutively. To change the launch sequence, move the section up or down in the list; see Working with Sections (page 2-6). Enabling and Disabling Sections If you don’t want to the application to launch at startup, you can delete the section. However, program sections contain settings you’ll want to keep when adding that same application back to startup. To keep the program section in the file for future reference, disable the program section instead of deleting it. Disabled sections appear in red. When processing files, the IK8560/8570 behaves as though disabled sections are not there and moves on to the next enabled section. Program Child Sections The following section is required and must be enabled. Section
Description
Reset
Initiates a warm boot after the cold boot during startup. Do NOT disable the Reset section!
The other sections launch the executable entered in the Program key. Program Section Keys Each program section should contain the following keys:
Key
Function
Program
Specifies the command line to execute. This is the location of the program’s executable. If you want a Power Tool to launch at startup, enter the location of that tool’s .exe here.
Args
Specifies the command line arguments to execute at startup.
Wait
Determines if Autorun should wait for the program to complete and close before continuing to the next program in the sequence. 0=Continue to the next program immediately 1=Wait enabled
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
4-3
Page 50
Key
Function
StartOption
Specifies the startup options for the program. Autorun launches the program only if the startup options entered here are met. Blank = Always run the program. For a complete list of values, see Startup Options on page 4-5.
Optional Keys - These are keys you can add as necessary. PNPID
Specifies a card description. This option needs to be entered only when PNPID or NONPNPID values are specified in the StartOption key.
DependIndex
Specifies the index (top to bottom) of a dependent program.
DependExitCode
Specifies the required result of the dependent program. If the result of the dependent program does not equal the DependExitCode entered here, the current program will not be executed at startup.
Editing the Autorun Configuration File Edit Autorun.exm in EZConfig Editor. For details, see Working with Open Configuration Files on page 2-6.
Adding a Program Section 1. In EZConfig Editor, right click on the Programs section and select Append Child Section.
A new program must be a child section of the Programs section to launch at startup. 2. On the Add New Section window, enter the Name and Description and click OK. 3. The new section is added to the bottom of the list.
4-4
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide