Page 161
ECHO The ECHO command has two functions; namely, control of the ECHO flag, and displaying messages in batch files. ECHO mode controls the command processor's echoing of commands in batch files. If ECHO mode is on, then commands read from batch files are automatically echoed to the screen before they are executed. If ECHO mode is off, then commands are not echoed as they are executed. To display the current ECHO flag status, use the ECHO command without any parameters. To display a message from a batch file, use the ECHO command with a non-empty string to be displayed. The special form of the ECHO command with a period (“.”) immediately following the word ECHO (no intervening space) causes a blank line to be echoed. Syntax: ECHO [ONlOFFlstring]
EXIT The EXIT command terminates the current command shell and reverts control to the previous shell, provided that the current command shell is not the first one loaded in the system. The very first shell cannot be terminated with EXIT. If executed from a batch file, EXIT will terminate the batch file in a controlled manner causing control to be transferred to the keyboard user. Syntax: EXIT
GOTO The GOTO command causes the command processor to start executing commands that follow the specified label, in the current batch file. Labels can be inserted anywhere in batch files, and take the following form: “: label”. Syntax: GOTO label
IF The IF command causes a command to be executed if (or if NOT) a condition is TRUE. Syntax: IF [NOT] ERRORLEVEL n statement IF [NOT] EXIST filename statement
Rev 1.3
161
Page 162
MD (MKDIR) The MD command creates a subdirectory in the root directory or a subdirectory. By using the MKDIR command, tree-structured file systems can be created. If a drive is specified, then the directory is created on the specified drive. Otherwise, it is created on the default drive. Syntax: MD [drive:]path
PATH The PATH command displays or changes the current search path that is used by the command processor, COMMAND.COM, to locate user programs and batch files. If no pathlist parameter is specified, then the current path is displayed. If a pathlist parameter is specified, then the path will be changed to the one specified. Syntax: PATH [pathl[;path2][;path3][;...]
PAUSE The PAUSE command is typically used in batch files to suspend execution of the batch file, print a message on the screen, and wait for the user to press a key after some action has been performed. PAUSE displays the following message on the screen before accepting a keypress from the user, “Strike any key when ready”. Syntax: PAUSE
PROMPT The PROMPT command maintains the PROMPT environment variable that is used by COMMAND.COM to display something before the user is asked to type-in a command. The default PROMPT variable is $n$g. This has the effect of showing the current drive letter followed by a "greater-than" sign: Syntax: PROMPT string
Rev 1.3
162
Page 163
RD (RMDIR) The RD command removes a subdirectory from a root directory or of a subdirectory. This command can only be used to delete directories, and cannot be used to delete files, even if they are inside the directory to be removed. Conversely, the DEL command cannot delete directories; only the files they contain. If a drive is specified, then the directory on the specified drive is removed. Otherwise, the default drive is assumed. Syntax: RD [drive:]path
REM The REM command provides a simple way of entering a free-form comment in a batch file. The line starting with REM has no effect on the execution of the batch file. Syntax: REM any comment
REBOOT The REBOOT command will reset the terminal. Syntax: REBOOT
REN The REN command renames a file or group of files. Files cannot be moved in the directory structure with this command; instead, only their filenames are altered within the directory in which they reside. Wildcards may be used in the second pathname to indicate that the characters in that component of the first filename are to be kept as-is. Syntax: REN [drive:][path]filespec filespec
Rev 1.3
163
Page 164
SHIFT The SHIFT command allows access to multiple batch file arguments. The command shifts the contents of the 9 batch file arguments so that %2 is copies into %1, %3 is copies into %2 and so on. Syntax: SHIFT SET The SET command displays the entire environment space (one variable per line), or changes the assignment of one variable in the environment space. If no operands are specified, then the SET command simply displays all of the environment variables in the environment space. If a variable name and an equal sign is given, but no string is specified, then the variable name is removed from the environment space. If the string is specified, then the previous definition of the variable is deleted, and the new one is installed in the environment. Syntax: SET [keyword=[string]]
SHIFT Displays or changes the optional switch character. Syntax: SWITCH [character]
Rev 1.3
164
Page 165
SYNC The SYNC command provides a synchronization checkpoint feature that enables a batch file to flush the file system's buffers to disk before doing something that might otherwise cause a disorderly shutdown Syntax: SYNC
TIME The TIME command displays or changes the system time. If no parameter is specified, then the current system time is displayed, and the user is queried for the new system time. If the user just presses the ENTER key, the system time is not changed. If the user enters a new time, then the system's real-time-clock is updated. Syntax: TIME [hh:mm:ss[.hh]] TRUENAME The TRUENAME command displays the true name and path of a file. Syntax: TRUENAME file TYPE The TYPE command copies the contents of the specified file to standard output (usually, the screen). If the drive letter is not specified, then the default drive is assumed. Syntax: TYPE [drive:][path]filespec
VER The VER command displays the MS-DOS emulation version number, as well as the version of the Embedded DOS-ROM operating system that is running. Syntax: VER
VERIFY
Rev 1.3
165
Page 166
The VERIFY command changes or displays how GS DOS handles I/O to disk files and directory structures. If VERIFY is ON, then Embedded DOS-ROM verifies immediately that disk I/O is completed successfully before telling the user that it was. This is accomplished by writing data directly to disk, without temporarily storing it in a file system or disk driver cache. If VERIFY is OFF, then GS DOS caches writes to files and defers the actual writing to disk, enabling multiple writes to the same sectors to be served much faster. The cache is automatically written to disk in the background during "dead time", when the disk is not busy. This is accomplished with the multitasking threads and semaphores that the GS DOS kernel supports. Syntax: VERIFY [ONIOFF]
VOL The VOL command displays the volume label of a diskette or a hard disk. VOL does not allow the user to change the volume label. If the drive letter is not specified, then the default drive is assumed. Syntax: VOL [drive:]
Rev 1.3
166
Page 167
Appendix F Declarations of Conformity Declaration of Conformity
EC declaration of conformity for the following: 89/336/EEC EMC Directive 73/23/EEC Low Voltage Directive as amended by 93/68/EEC 1. Product Identification Product name Line of business Model/type Version Additional information
: Dolphin 1 Terminal and Homebase : Auto ID : N/A : N/A : This Product was tested with the following: Dolphin 1 Terminal Bar Code Scanner Dolphin 1 Homebase
2. Manufacturer Name Address Country Authorized by manufacturer
: Hand Held Products, Inc. : 7510 E. Independence Blvd. #100 Charlotte, North Carolina 28227-9411 : United States Of America : Corporate Body: Trading as: Fleuri Kets V B.V. Hand Held Products Europe Kaatsheuvel Hondsruglaan 87d The Netherlands 5628 DB Eindhoven The Netherlands
3. Test lab Name Address Country
: Instrument Specialties : Delaware Water Gap, Pennsylvania 18327-0136 : United States of America
4. Applied standards Name/numbers
:ITE Emissions EN 55022 :Generic Immunity for Res./Comm./Lt. Ind. EN 50082-1 :Electrostatic Discharge Immunity IEC 1000-4-2 :Radiated EMI Field Immunity (IEC 801-3) IEC 1000-4-3 :Fast Transient / Burst Immunity IEC 1000-4-4
5. Test report Name/number
:ITE Emissions :Generic Immunity for Res./Comm./Lt. Industrial :Electrostatic Discharge Immunity 45889 :Radiated EMI Field Immunity (IEC 801-3) :Fast Transient / Burst Immunity 45889
45889 45889 45889
6. Declaration We, mentioned at point 2, declare on our own full responsibility that the product mentioned at point 1 complies with the directive 89/336/EEC. This is based upon testing of a sample of the product mentioned at point 1, performed by the test lab mentioned at point 3, according to the harmonized standards corresponding to article 10 (1) of the directive 89/336/EEC. These standards are mentioned at point 4. The results of the tests are given in the report mentioned at point 5.
7. Authentication Signature in behalf of authorized company mentioned at point 2 :
Date :
Signature On File J.H. Cottrell Jr., Managing Director, Hand Held Products Europe _________________ Place : _________________
167
Page 168
Declaration of Conformity EC declaration of conformity for the following: 89/336/EEC EMC Directive 73/23/EEC Low Voltage Directive as amended by 93/68/EEC 1. Product Identification Product Name Line of Business Model/Type Version Additional Information
: Dolphin RF 2.4 GHz Portable Data Collection Terminal : Auto ID : N/A : N/A : This product was tested with the following: Dolphin I Homebase.
2. Manufacturer Name Address Country Authorized by Manufacturer
: Hand Held Products. Inc. : 7510 East Independence Blvd. Charlotte, North Carolina 28227-9411 : United States of America : Corporate Body: Trading As: Fleuri Kets V B.V. Hand Held Products Europe Kaatsheuvel Hondsruglaan 87d The Netherlands 5628 DB Eindhoven The Netherlands
3. Test Labs Name Address Country
: Teleficaton BV : Utrechtseweg 310 : The Netherlands
Name Address Country
: SGS US Testing Company Inc : 291 Fairfield Avenue : Fairfield, NJ 07004 USA
4. Applied Standards Name/Numbers
: ITE Emissions EN 55022:1995 : Electromagnetic Immunity for Res,/Comm./Lt. Industrial ETS 300 826:1997 Including: : Electrostatic Discharge Immunity EN 61000-4-2:1995 : Radiated EMI Field Immunity EN 61000-4-3:1996 : Fast Transient / Burst Immunity EN 61000-4-4:1995 : Conducted RF Immunity EN 61000-4-6:1996 : Safety of Information Technology Equipment, Including Electrical Business Equipment (LVD) EN 60950:1992
Page 1 of 2 Revision C
Rev 1.3
168
Page 169
Declaration of Conformity EC declaration of conformity for the following: 89/336/EEC EMC Directive 73/23/EEC Low Voltage Directive as amended by 93/68/EEC 5. Test Report Name/Number
: Telefication : ITE Emissions : Electromagnetic Immunity for Res./ Comm,/Lt. Ind. (as listed above): : SGS : LVD Compliance
98302120 98302120 U0212
6. Type Approval Certifications Country/Approval Number : FCC/USA : Canada : Netherlands, UK, Austria : Germany : Switzerland : Denmark : Norway : Sweden : Belgium : Italy : Hungary : Greece : Ireland : Spain : France
: HD5RFDolphin-1 : 16931021078A : NL98062970 : D800372K : 98.0517.L.P : CEPT/RLAN/DK/9817 : CEPT/RLAN N NO98000529-R : Ue980117 : RTT/RL/X070 : DGPGF/4/2/334473/2590/061098 : 1705-2/99 : CEPT-RLAN-GR.YME TA 164 : IRL TRA 24/5/242/1 : E/D.G.Tel./08/99/0221 : 980321PPO
7. Declaration We, mentioned at point 2, declare on our own full responsibility that the product mentioned at point 1 complies with the directive 89/336/EEC and 73/23/EEC as amended by 93/68/EEC. This based upon testing of a sample of the product mentioned at point 1, performed by the test labs mentioned at point 3, according to the harmonized standards corresponding to article 10 (1) of the directive 89/336/EEC and to 73/23/EEC as amended by 93/68/EEC. These standards are mentioned at point 4. The results of the tests are given in the reports mentioned at point 5.
8. Authentication Signature on behalf of authorized Company mentioned at point 2: Signature on file J.H. Cottrell Jr., Managing Director, Hand Held Products, Europe Date : October 27th , 1998
Page 2 of 2 Revision C
Rev 1.3
169
Place: North Carolina, USA
Page 170
170