The text of a manual · part 5 of 19
4800p 2D Imager User's Guide, pages 41 to 50
Pages 41 to 50 of 184
The original document is the PDF (918 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP 4800p and Honeywell 4800p
Page 41
* Upright
Rotate Code Clockwise 90° (Rotate Imager Counterclockwise) Upside Down
Rotate Code Counterclockwise 90° (Rotate Imager Clockwise)
3 - 13
Page 42
3 - 14
Page 43
4
Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string:
Prefix 1-11 alpha numeric characters
Scanned Data variable length
Suffix 1-11 alpha numeric characters
Points to Keep In Mind • It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the ASCII Conversion Chart (Code Page 1252), page A-4, plus Code I.D. and AIM I.D. • You can string together several entries for several symbologies at one time. • Enter prefixes and suffixes in the order in which you want them to appear on the output. • When setting up for specific symbologies, instead of All Symbologies, the symbology ID value counts as an added prefix or suffix character.
To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-4). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in Appendix A) for the symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies.
4-1
Page 44
Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252), page A-4, for the prefix or suffix you wish to enter. Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Step 6. Repeat Steps 4 and 5 for every prefix or suffix character. Step 7. To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C.
Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once to create the leading backslash and then to create the backslash itself. Step 8. Scan Save to exit and save, or scan Discard to exit without saving. Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example: Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for U.P.C. only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Chart (included in Appendix A) for U.P.C. Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this manual. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252), page A-4, for the CR (carriage return). Step 5. Scan 0, D from the Programming Chart inside the back cover of this manual. Step 6. Scan Save, or scan Discard to exit without saving.
To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in Appendix A) for the symbology from which you want to clear the prefix or suffix.
4-2
Page 45
Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Your change is automatically saved.
To Add a Carriage Return Suffix to all Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.
Add CR Suffix All Symbologies
4-3
Page 46
Prefix Selections
Add Prefix
Clear One Prefix
Clear All Prefixes
Suffix Selections
Add Suffix
Clear One Suffix
Clear All Suffixes
Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the imager transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 9-3. When the imager is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.
* Enable
Disable
4-4
Page 47
Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each) for a range of 0-495 ms.
Intercharacter Delay An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5 millisecond steps (0-99), and the Save bar code using the Programming Chart inside the back cover of this manual. Prefix
Scanned Data 1
2
3
4
Suffix 5
Intercharacter Delay
Intercharacter Delay To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
4-5
Page 48
User Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed after the transmission of a particular character of scanned data. Scan the Delay Length bar code below, then scan the number of 5 millisecond steps (0-99), and the Save bar code using the Programming Chart inside the back cover of this manual. Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for the ASCII character that will trigger the delay ASCII Conversion Chart (Code Page 1252), page A-4.
Delay Length
Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of steps to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.
Interfunction Delay An interfunction delay of up to 495 milliseconds (in 5 ms steps) may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of 5 millisecond steps (0-99), and the Save bar code using the Programming Chart inside the back cover of this manual. Prefix STX
1
Scanned Data HT
2 3 4 5
Suffix CR
LF
Interfunction Delays
Interfunction Delay To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.
4-6
Page 49
Intermessage Delay An intermessage delay of up to 495 milliseconds (in 5 ms steps) may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of 5 millisecond steps (0-99), and the Save bar code using the Programming Chart inside the back cover of this manual.
1st Scan Transmission 2nd Scan Transmission Intermessage Delay
Intermessage Delay To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.
4-7
Page 50
4-8