The text of a manual · part 4 of 19
4800p 2D Imager User's Guide, pages 31 to 40
Pages 31 to 40 of 184
The original document is the PDF (918 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP 4800p and Honeywell 4800p
Page 31
Good Read Delay This sets the minimum amount of time before the imager can read another bar code. Default = No Delay.
* No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
Long Delay (1,500 ms)
User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
User-Specified Good Read Delay
3-3
Page 32
Reread Delay This sets the time period before the imager can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. Use shorter delays in applications where repetitive bar code scanning is required. Default = Medium.
Short (500 ms)
* Medium (750 ms)
Long (1000 ms)
Extra Long (2000 ms)
User-Specified Reread Delay If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
User-Specified Reread Delay
3-4
Page 33
LED Power Level This selection allows you to adjust LED and aimer brightness. Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting.
Note: If you scan the Off bar code, both the aimer and illumination lights turn off, making it impossible to scan bar codes in low light. To turn the LED Power Level back on, move to a brightly lit area and scan either the Low or the High bar code below.
Off
Low (50%)
* High (100%)
Centering Use Centering to narrow the imager’s field of view to make sure the imager reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. In the example below, the gray area is the full imager field of view and the white area is the centering window. Bar Code 1 will not be read, while Bar Code 2 will be. Bar Code 1
Bar Code 2
3-5
Page 34
The default centering window is a 128x96 pixel area in the center of the imager’s field of view. The following diagram illustrates the default top, bottom, left, and right pixel positions, measured from the top and the left side of the imager’s field of view, which is 640 by 480 pixels. 40%
60%
100%
0
Top 40%
Bottom
Default Center
60%
Left Right 100%
If a bar code is not within the predefined window, it will not be decoded or output by the imager. If centering is turned on by scanning Centering On, the imager only reads codes that intersect the centering window you specify using the Top, Bottom, Left, or Right bar codes. Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right.
Centering On * Centering Off Top of Centering Window
Bottom of Centering Window
Left of Centering Window
Right of Centering Window
3-6
Page 35
Decode Search Mode There are three selectable decode (scanning) modes:
Full Omnidirectional - Searches for bar code features beginning at the center of an image, and searches to the image’s limits. This mode reads all symbologies (including OCR), in any orientation. The Full Omnidirectional search is very thorough which may slow performance time. Note: This search mode is the default setting.
*Full Omnidirectional
Quick Omnidirectional - This is an abbreviated search for bar code features around the center region of an image. This mode quickly reads all symbologies in any orientation. The Quick Omnidirectional mode may miss some off-center symbols, as well as larger Data Matrix and QR Code symbols.
Quick Omnidirectional
Advanced Linear Decoding - Performs quick horizontal linear scans in a center band of the image. This mode is not omnidirectional, but does quickly read linear and stacked bar codes. Advanced Linear Decoding cannot read 2D, OCR, or Postal symbols.
Advanced Linear Decoding
Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the Imager decodes it. When turned on, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device.
Note: This selection is unavailable when Print Weight (page 3-11) is enabled.
3-7
Page 36
Output Sequence Editor This programming selection allows you to program the imager to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the imager to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol.
Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires. Use the Alphanumeric symbols (inside back cover) to read these options. You must hold scan each bar code in the sequence. To Add an Output Sequence 1. Scan the Enter Sequence symbol (see Require Output Sequence, page 310). 2. Code I.D. On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) When calculating the length, you must count any programmed prefixes, suffixes, or formatted characters as part of the length (unless using 9999). 4. Character Match Sequences On the ASCII Conversion Chart (Code Page 1252), page A-4, find the Hex value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters. (99 is the Universal number, indicating all characters.) 5. End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology, or Save to save your entries.
Other Programming Selections •Discard This exits without saving any Output Sequence changes.
3-8
Page 37
Output Sequence Examples In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the imager to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.
Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93 You would set up the sequence editor with the following command line: SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below: SEQBLK 62 9999 41 FF 6A 9999 42 FF 69 9999 43 FF sequence editor start command code identifier for Code 39 code length that must match for Code 39, 9999 = all lengths start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 code length that must match for Code 128, 9999 = all lengths start character match for Code 128, 42h = “B” termination string for second code code identifier for Code 93 code length that must match for Code 93, 9999 = all lengths start character match for Code 93, 43h = “C” termination string for third code
To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page 3-9, but assume a <CR> suffix and specific code lengths, you would use the following command line: SEQBLK62001241FF6A001342FF69001243FF
3-9
Page 38
The breakdown of the command line is shown below: SEQBLK 62 0012 41 FF 6A 0013 42 FF 69 0012 43 FF sequence editor start command code identifier for Code 39 A - Code 39 sample length (11) plus CR suffix (1) = 12 start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 B - Code 128 sample length (12) plus CR suffix (1) = 13 start character match for Code 128, 42h = “B” termination string for second code code identifier for Code 93 C - Code 93 sample length (11) plus CR suffix (1) = 12 start character match for Code 93, 43h = “C” termination string for third code
Output Sequence Editor
Enter Sequence
Default Sequence
Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device. When it’s On/Not Required, the imager will attempt to get the output data to conform to an edited sequence, but if it cannot, the imager transmits all output data to the host device as is.
3 - 10
Page 39
When the output sequence is Off, the bar code data is output to the host as the imager decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Required
On/Not Required
*Off
Print Weight Print Weight is used to adjust the way the imager reads Matrix symbols. If an imager will be seeing consistently heavily printed matrix symbols, then a print weight of 6 may improve the reading performance. For consistently light printing, a print weight of 2 may help. After scanning the Set Print Weight bar code, set the print weight (from 1-7) by scanning digits from the inside back cover, then scanning Save. Default = 4.
Set Print Weight
* Default
3 - 11
Page 40
Video Reverse Video Reverse is used to allow the imager to read bar codes that are inverted. The “Off” bar code below is an example of this type of bar code. If additional menuing is required, Video Reverse must be disabled to read the menu bar codes and then re-enabled after menuing is completed.
Note: Images downloaded from the unit will not be reversed. This is a setting for decoding only.
On
* Off
Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the imager. Default = Upright. Upright:
Rotate Code Clockwise 90°:
Upside Down:
Rotate Code Counterclockwise 90°:
3 - 12