Page 51
5
Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the imager’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None. Normally, when you scan a bar code, it gets outputted automatically; however when you do a format, you must use a “send” command (see Send Commands on page 5-2) within the format program to output data. Multiple formats may be programmed into the imager. They are stacked in the order in which they are entered. However, the following list presents the order in which formats are applied: 1. Specific Term ID, Actual Code ID, Actual Length 2. Specific Term ID, Actual Code ID, Universal Length 3. Specific Term ID, Universal Code ID, Actual Length 4. Specific Term ID, Universal Code ID, Universal Length 5. Universal Term ID, Actual Code ID, Actual Length 6. Universal Term ID, Actual Code ID, Universal Length 7. Universal Term ID, Universal Code ID, Actual Length 8. Universal Term ID, Universal Code ID, Universal Length If you have changed data format settings, and wish to clear all formats and return to the factory defaults, scan the Default Data Format code on page 5-4.
To Add a Data Format Step 1. Scan the Enter Data Format symbol (page 5-4). Step 2. Primary/Alternate Format Determine if this will be your primary data format, or one of 3 alternate formats. (Alternate formats allow you “single shot” capability to scan one bar code using a different data format. After the one bar code has been read, the imager reverts to the primary data format. See page 55.) If you are programming the primary format, scan 0 using the Programming Chart inside the back cover of this manual. If you are programming an alternate format, scan 1, 2, or 3, depending on the alternate format you are programming. Step 3. Terminal Type Refer to Supported Terminals (page 2-2) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the imager for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. Note: The wildcard for all terminal types is 099.
5-1
Page 52
Step 4. Code I.D. In Appendix A, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Step 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to Data Format Editor Commands (page 5-2). Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format. Step 7. Scan Save from the Programming Chart inside the back cover of this manual to save your entries.
Other Programming Selections • Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the alternate format you are clearing. Scan the Terminal Type and Code I.D. (see Supported Terminals on page 2-2), and the bar code data length for the specific data format that you want to delete. All other formats remain unaffected. • Save from the Programming Chart inside the back cover of this manual This exits, saving any Data Format changes. • Discard from the Programming Chart inside the back cover of this manual This exits without saving any Data Format changes.
Data Format Editor Commands Send Commands F1 Send all characters followed by “xx” key or function code, starting from current cursor position. Syntax = F1xx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.) F2 Send “nn” characters followed by “xx” key or function code, starting from current cursor position. Syntax = F2nnxx (nn stands for the numeric value (00-99) for the number of characters and xx stands for the hex value for an ASCII code. See ASCII Conversion Chart (Code Page 1252), page A-4.) F3 Send up to but not including “ss” character (Search and Send) starting from current cursor position, leaving cursor pointing to “ss” character followed by “xx” key or function code. Syntax = F3ssxx (ss and xx both stand for the hex values for ASCII codes, see ASCII Conversion Chart (Code Page 1252), page A-4.)
5-2
Page 53
F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4, and nn is the numeric value (00-99) for the number of times it should be sent.) E9 Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (nn is the numeric value (00-99) for the number of characters that will not be sent at the end of the message.)
Move Commands F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved ahead.) F6 Move the cursor back “nn” characters from current cursor position. Syntax = F6nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved back.) F7 Move the cursor to the beginning of the data string. Syntax = F7. EA Move the cursor to the end of the data string. Syntax = EA
Search Commands F8 Search ahead for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F8xx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.) F9 Search back for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F9xx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.) E6 Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. Syntax = E6xx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4. E7 Search back for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. Syntax = E7xx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.)
Miscellaneous Commands FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number of suppressed characters in the list and xxyy .. zz is the list of characters to be suppressed. (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.) FC Disables suppress filter and clear all suppressed characters. Syntax = FC. E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines charac-
5-3
Page 54
ters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. E5 Terminates character replacement. Syntax = E5. FE Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.) EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC. ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED.
Data Format Editor
Enter Data Format
* Default Data Format
Clear One Data Format
Clear All Data Formats
Save
Discard
5-4
Page 55
Data Formatter When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes). Choose one of the following options. Default = Data Formatter On, but Not Required.
* Data Formatter On, but Not Required Data Formatter Off When Data Formatter is required, all input data must conform to an edited format or the imager does not transmit the input data to the host device.
Data Format On, Format Required
Alternate Data Formats Alternate formats allow you “single shot” capability to scan one bar code using a different data format than your primary format. When data formats are programmed (see page 5-1), you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3. An alternate format is initiated by scanning one of the 3 alternate format bar codes below. The imager will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format.
Alternate Data Format 1
Alternate Data Format 2
Alternate Data Format 3
5-5
Page 56
5-6
Page 57
6
Symbologies This programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults. • All Symbologies
• Interleaved 2 of 5
• Australian Post
• Interleaved 2 of 5
• Aztec Code
• Japanese Post
• British Post
• Kix (Netherlands) Post
• Canadian Post
• Korea Post
• China Post
• Matrix 2 of 5
• Codabar
• MaxiCode
• Codablock F
• MicroPDF417
• Code 11
• MSI
• Code 128
• PDF417
• Code 16K
• Planet Code
• Code 39
• Plessey Code
• Code 49
• PosiCode A and B
• Code 93
• Postal-4i (UPU 4State)
• Data Matrix
• Postnet
• EAN/JAN-13
• QR Code
• EAN/JAN-8
• Straight 2 of 5 IATA
• GS1 Composite Codes
• Straight 2 of 5 Industrial
• GS1 DataBar Expanded
• TCIF Linked Code 39 (TLC39)
• GS1 DataBar Limited
• Telepen
• GS1 DataBar Omnidirectional
• UPC-A
• Intelligent Mail Bar Code
• UPC-A/EAN-13 with Extended Coupon Code
6-1
Page 58
All Symbologies If you want to decode all the symbologies allowable for your imager, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology.
All Symbologies On
All Symbologies Off
Message Length Description You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the Programming Chart inside the back cover of this manual. The minimum and maximum lengths and the defaults are included with the respective symbologies.
6-2
Page 59
Codabar <Default All Codabar Settings>
Codabar
* On
Off
Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
Transmit
* Don’t Transmit
Codabar Check Character Codabar check characters are created using different “modulos.” You can program the imager to read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character.
No Check Character indicates that the imager reads and transmits bar code data with or without a check character. When Check Character is set to Validate and Transmit, the imager will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.
6-3
Page 60
When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data.
* No Check Character
Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit
Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the imager looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Character Start
Stop
Start
Stop
Codabar A12D
D34A
Select Require to prevent the imager from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters.
On
* Off
Require
6-4