The text of a manual · part 5 of 6
iPAD Operations Guide (Draft), pages 41 to 50
Pages 41 to 50 of 60
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Fujitsu IPAD100
Page 41
WARNING Do not look into the reading aperture while a scanning beam is being emitted. Doing so can injure the eyes. For Reference A scanning beam stops in about one second if you continue to press the trigger key but no bar code is detected from the reading aperture. If a bar code cannot be read, try changing the direction of the scanning beam in relation to the bar code or the distance of the IPAD from the barcode. Note that if the scanning beam passes over more than one bar code, it cannot be determined which of the bar codes will be read.
6.2
Bar Code Specifications
Item PCS value Resolution Reading angle
Reading depth
Specifications 0.25 or more (Value for a 650 nm laser beam) 0.13 mm Vertical direction: ± 65o or less Horizontal direction: ± 60o or less Rotation: ± 30o or less Narrow bar Distance width 0.13 mm 5.6 to 12.7 cm 0.19 mm 4.6 to 19.0 cm 0.25 mm 5.08 to 24.6 cm 0.33 mm 5.08 to 30.4 cm 0.51 mm * to 38.1 cm 1.02 mm * to 55.8 cm 1.40 mm * to 73.6 cm LED indication (green)
Reading confirmed by: * The minimum reading distance is determined by the bar code label width and the reading depth.
6.3
Cleaning the Reading Aperture of the Bar Code Scanner
The reading aperture of the bar code reader must always be clean when it is used. Clean the reading aperture using a dry cloth or a cloth moistened with water or a diluted neutral detergent solution. Do not use alcohol, thinner, or other volatile solvent.
39
Page 42
6.4
Bar Code Sample Chart
Use the sample chart to check whether the scanner is faulty. NW7
Code 39
JAN standard
JAN abbreviated
UPC/E
UPC/A
Code 128
InterLeaved2of5
40
Page 43
EAN-8
EAN-13
CAUTION This chart may become illegible due to age or improper handling of the User's Manual.
7
Magnetic Card Reader
(1) After making sure of the orientation (direction of the arrow, for example), insert a magnetic card. (2) Slowly move the magnetic card from left to right. Note A magnetic card will not be read correctly if movement stops part way, the speed of movement changes, or the card is not moved parallel with the slot. The LED can be made to light by an application when a magnetic card is read 41
Page 44
correctly.
<Cleaning the magnetic card reader> The magnetic card reader becomes contaminated with dirt and dust from use. Clean the reader using the cleaning card supplied as an accessory.
− Cleaning cycle: Clean the reader every month or whenever errors are frequent. − Cleaning method: Insert the cleaning card (supplied) in the reader with the rough side (cleaning side) facing up. (Insertion is the same as for a magnetic card.)
− Replacement cycle: Replace the cleaning card (supplied at a cost) when it becomes contaminated. If errors still occur after the reader has been cleaned, notify your Fujitsu maintenance representative.
CAUTION Before cleaning the reader, turn off the IPAD to guard against a possible malfunction.
8
IC Card Reader/Writer (Installed in the IPAD100-20) Figure 1
IC card slot
The IPAD100-20 is equipped with an IC card reader.
(1) When instructed to by message, insert an IC card in the IC card slot with the IC terminal side facing up.
42
Page 45
Figure 2
<Cleaning the IC card reader/writer> The contacts of the IC card reader/writer become contaminated with dirt and dust from use. Clean the reader using the cleaning card supplied as an accessory.
− Cleaning cycle: Clean the reader every month or whenever errors are frequent.
− Cleaning method: Insert the cleaning card in the reader with the rough side (cleaning side) facing up. (Insertion is the same as for an IC card.)
− Replacement cycle: Replace the cleaning card (supplied at a cost) when it becomes contaminated. If errors still occur after the reader has been cleaned, notify your Fujitsu maintenance representative.
CAUTION Before cleaning the reader, turn off the iPAD to guard against a possible malfunction.
43
Page 46
9
User Action in Response to Messages If any of the following messages are displayed, take the action described in the following table.
Message Main battery alarm
Cause The main battery The front light is off. charge is too low.
Auxiliary battery alarm
Is this the initial installation?
The auxiliary battery charge is too low. No application programs have been installed.
A power failure may The have occurred. memory data was deleted because, for example, the battery charge was too low. An error was An error detected on the flash occurred in disk. the system information storage area of the flash ROM.
User response Either replace the main battery or charge the main battery using the battery charger or cradle. >>Reference>> Section 1.2.2, "Charging the main battery" Section 1.2.3, "Installing and removing the main battery" Charge the auxiliary battery. >>Reference>> Section 1.2.4, "Charging the auxiliary battery" Press the [SFT] and [CAN] keys simultaneously to install application programs. >>Reference>> "IPAD Systems Users Guide" Press the [SFT] and [CAN] keys simultaneously to automatically recover the application programs. >>Reference>> "iPAD Systems Users Guide"
Tap the [OK] button to initialize the flash ROM and then reinstall the application programs. >>Reference>> "iPAD Systems Users Guide"
44
Page 47
10 Troubleshooting If you encounter any of the problems described in the following table while using the IPAD, take the indicated action before notifying your maintenance representative. Problem The IPAD cannot be turned on.
User response The main battery has no charge. Replace it with a charged main battery. >>Reference>> Section 1.2, "Using the Battery" Alternatively, charge the main battery. >>Reference>> Section 1.2.2, "Charging the main battery" If the main battery is completely dead, all the data and information in memory in the IPAD may be lost. If data has been lost, reinstall the applications again. The service life of the main battery has expired or the battery is faulty. Install a new main battery. >>Reference>> Section 1.2, "Using the Battery"
The iPAD cannot be turned on. (continued)
The main battery may not be correctly installed. Install the main battery correctly. >>Reference>> Section 1.2.3," Installing and removing the main battery" The battery lock switch may be unlocked. >>Reference>> Section 3.7.2, "Completely resetting the iPAD” The screen appears for a moment, then turns The main battery may have no charge. Replace it with a charged black when you press the main battery. Power key to turn on the power. >>Reference>> Section 1.2, "Using the Battery" The speaker is silent. The speaker may be set to "Low." Check the volume setting of the speaker. >>Reference>> Section 3.3," Adjusting the Volume" The touch panel does not respond. The coordinates on the touch panel may be misaligned. Perform touch panel correction. >>Reference>> Section 3.5, "Correcting the Coordinates on the Touch Panel" The front light is dark or turns black. The main battery may have no charge. Replace it with a charged main battery. >>Reference>> Section 1.2, "Using the Battery"
45
Page 48
11 Correctly Using the iPAD 11.1 Using the main battery To prevent deterioration, do not store the main battery for a long time when it is fully charged. For long-term storage, remove the battery from the IPAD when it is about 50% charged and store it at room temperature. If the battery has not been used for a long time, recharge it. Be careful not to short-circuit the battery terminals with a necklace or other metallic object. Do not heat the battery or throw it into a fire. Do not leave the battery in a car exposed to sunlight or in direct sunlight. Do not allow the battery to become wet. Do not apply a strong shock to the battery. Do not drop the battery. Using the iPAD at low temperatures (below 50oF)
− At low temperatures (below 50oF), the iPAD does not operate as long as it does at room temperature. In an environment of 50oF, operating time is about 70% of that at room temperature, and in an environment of 32oF, it is about 50% (new battery used). If operation in a low-temperature environment is possible, review charging procedures and operation.
− In operation at low temperatures (below 50oF), replacing the battery with one that is only partially charged will result in a very short operating time. Be sure to replace the battery with a fully charged one.
− Keep a spare battery warm until you use it by, for example, putting it in your pocket. If you warm a battery with a body warmer, be careful that the battery does not come into direct contact with the body warmer. If a message indicating that charging is required (battery status message) is displayed, promptly charge the battery or replace the battery with a spare battery. Be careful that no dust, sand, or other foreign matter enters the terminal section while you are using the iPAD. If any foreign matter gets in, completely remove it using a soft-tipped cotton swab or gauze, then repeat several times inserting the iPAD into the charger or device and then removing it. The iPAD may not charge if the terminals are dirty. Despite complete charging, the battery naturally discharges little by little as time passes. If possible, charge the battery again just before using it (within one or two days). Store the battery in as cool a place as possible and charge it at an ambient temperature of 50oF to 86oF. Doing so will increase the life of the battery.
11.2 Using the auxiliary battery Auxiliary battery alarm message A warning message appears in the center of the screen if the voltage of the auxiliary battery drops or the auxiliary battery is not connected. The programs and data in memory will be lost if you replace the main battery while this message is displayed. Immediately charge the auxiliary battery. 46
Page 49
>>Reference>> For information about charging the auxiliary battery, see Section 1.2.4, "Charging the auxiliary battery."
11.3 Long-term storage Store the iPAD where it will not be exposed to vibration, dust, high and low temperatures, high humidity, and direct sunlight. Storing the iPAD with the programs saved To avoid discharging of the main and auxiliary batteries, charge the main battery once every week. Without charging, the programs and data in memory will be lost. Storing the iPAD without the programs saved To store the iPAD without the programs saved, remove the main battery and completely reset the iPAD. >>Reference>> For information about removing the battery, see Section 1.2.3," Installing and removing the main battery," and Section 1.2.4, "Charging the auxiliary battery." For information about completely resetting the iPAD, see Section 3.7.2, "Completely resetting the iPAD."
11.4 Cleaning Clean the cover of the iPAD using a cloth moistened with a solution of water and neutral detergent and wrung out or a dry cloth. If you use a damp cloth, be sure to wring it out thoroughly to prevent water from getting into the iPAD, causing a malfunction. Do not wipe the iPAD using thinner, benzine, or other volatile solvent. Such materials can discolor the iPAD or erase printed characters. Wipe the display area of the iPAD using a cloth moistened with water and wrung out thoroughly or a glass wipe with a very fine texture. Occasionally clean the cradle interface using a dry cotton swab or gauze. If the terminals become dirty, contact may be poor, causing the IPAD to turn off or disabling normal charging and communication.
11.5 Other precautions Do not disassemble or modify the iPAD. To prevent the iPAD from malfunctioning, do not leave the iPAD, even for a short time, where it is exposed to any of the following conditions:
− − − − − −
Extreme heat (for example, car in sunlight with the windows closed) Direct sunlight Extreme heat or cold Dust Strong vibration Humidity
Do not apply a strong shock to the iPAD. Do not drop the iPAD. Be careful not to hold the iPAD for a long time in a high-temperature environment (95oF or higher). Doing so may result in a low-temperature burn. 47
Page 50
A
Specifications
Item
Controller
Display section
CPU Memory OS Type Screen size Display lighting
Operator section
Strage card External interfaces Power supply
Main-Battery Operating time
Main-Battery charging time
Specification
Intel XScale-400MHz ROM: 32M bytes RAM: 64M bytes(SDRAM) FFS 32MB Windows CE .NET 3.5-inch TFT reflective color LCD 240 (H) × 320 (V) dots High-intensity front light Touch panel (resistive-film type), trigger switches (bar code scanner input), power key, function keys, set key, cursor keys, clear key, numeric keypad, × key, / key, decimal-point (.) key, cancel key, enter key, shift key, and cellular phone input mode (alphabetic/hiragana input) Compact flash × 1 slot (RF-LAN card) Cradle I/F: USB client (for PC connection) Charge terminals Lithium ion battery pack, 3.7 V 1700 mAh About 3 hours (new battery, room temperature, wireless communication in progress for 10% of the time, scanner reading once every ten seconds, and front light on at the "dark" setting) About 7 hours (new battery, room temperature, wireless communication in progress for 10% of the time, and front light off) About 2.5 hours (unit power off, operating from the cradle) About 2.5 hours (With the battery pack charger)
Sub-Battery charging time Item Environmental Temperature conditions Relative humidity
About 24 hours (from the Main-Battery)
Scanner
JAN/EAN-13/8,UPC-A/E,NW-7,CODE39/128,Interleaved2of5 (ITF)
Audio
Speaker×1 built-in, Microphone×1 built-in Headset connector(input/output) JIS Ⅰ(ISO1/2), JISⅡ
Magnetic card reader
Specification Operating: 0 to 40°C (non-condensing) Idle: -20 to 60°C (non-condensing) Operating: 20 to 85% (non-condensing) Idle: 20 to 85% (non-condensing)
48