7. Online mode
7.3.1 Capability of Online Mode You may activate the following applications in Online Mode through the function keys illustrated in Fig. 7.11: Display SF 3 information This function provides an easy, function key-controlled use of Online Mode. You can view and modify operands, system states, errors etc (see sections 7.4 and 7.5).
You do not require any further knowledge of the command language for the command interpreter. Macro handling This function opens up macro-controlled use of Online Mode (see section 7.7).
You should have thorough knowledge of the command interpreter.
9610a
7-19
Page 332
FST 200
7. Online mode
Terminal Mode Terminal Mode allows you to work directly in the command interpreter of the controller (see section 7.8). In this operating mode, your PC is merely a terminal for the controller.
Comprehensive knowledge of the command interpreter is required for this function. See SF 3 description "Electronics" in Appendix C in this regard. Reset SF 3 Function F4 initialises the program directory for the controller and deletes possible errors in the controller.
The entire user memory is deleted. System configuration This is used to set the operating mode for the SF 3. Depending on the operating mode selected, you may also have to set: • The field bus baud rate and address, • The number of cyclical inputs/outputs and • The terminating resistor. The Automode setting can also be switched on or off.
7-20
9610a
Page 333
FST 200
7. Online mode
I/O configuration This function displays the configuration of the connected valve terminal and the address space occupied by the modules. The following are displayed: • Specification of the valve terminal type. • Pneumatics configuration with assignment to the operands. • Configuration of the digital I/Os with assignment to the operands. • Specification of the type of all detected analogue modules. • Specification of the AS-i master with assignment to the operands. • Specification of the CP interface with assignment to the operands. SF 3 DIR Function F7 brings up an index of all the user programs, program modules and files saved in the controller connected.
9610a
7-21
Page 334
FST 200
7.4
7. Online mode
Display SF3-INFO The SF3-INFO display offers you the easiest way of operating Online Mode, as it is function key-controlled. You can access this menu from the Online Mode opening menu by selecting function F1.
Fig. 7.12: Menu Display SF3 information From this screen you can have information relating to all the operands of your controller, to any error states and to the system status displayed on the screen by selecting the functions shown along the bottom of the screen.
7-22
9610a
Page 335
FST 200
7. Online mode
Modifying operand values You may modify the values displayed by entering the following: • a 5-digit decimal number between 0000 and 65535 • a 4-digit hexadecimal number between $0000 and $FFFF. Confirm the modifications entered by pressing the ENTER key. This action is valid for all entries of this type. You may modify individual bits in just the same way. This is done by moving the grey input field to the right with the Tab key. This changes the function key assignment to F1 Set operand F2 Reset operand F3 Toggle operand F8 Return Quit this bit-by-bit modification mode with the Home key.
9610a
7-23
Page 336
FST 200
7. Online mode
Displaying the values The information on the screen is initially static, i.e. you are shown the values of the operands or states at the time of selection. You can also have these values displayed dynamically, to keep a watch on the running control process (see section 7.5: Dynamic display). 7.4.1 Static display of the inputs and outputs When you select function F1 the instantaneous values of the connected local digital inputs and outputs are displayed on the screen for you. The field bus I/Os can be displayed in the Master operating mode by selecting function F7 (Fig. 7.14). Depending on the configuration of the valve terminal, the AS-i I/Os (Fig. 7.15) and the I/Os for the CP interface (Fig. 7.16) may also be displayed.
7-24
9610a
Page 337
FST 200
7. Online mode
Fig. 7.13: Display of local inputs and outputs Display operand value The inputs and outputs are displayed both bit-by-bit and as input and output words. I/O [y.]<t>.<t> =
9610a
5-digit decimal = 8/16-digit binary or 5-digit decimal +/- = 8/16-digit binary or $ 4-digit hexadecimal = 8/16-digit binary
7-25
Page 338
FST 200
7. Online mode
Field bus I/Os and diagnostics When you select function F7, the instantaneous values of all local diagnostic bytes, field bus diagnostic bytes and all configured field bus I/Os are displayed on the screen for you.
Fig. 7.14: Display of the field bus I/Os and diagnostics (local and field bus)
7-26
9610a
Page 339
FST 200
7. Online mode
Display of AS-i outputs When you select function F1 the instantaneous values of the connected local digital inputs and outputs are displayed on the screen for you. Browsing with the F1 and F2 keys will bring up the display of the AS-i outputs.
Fig. 7.15: Display of the AS-i-master outputs
9610a
7-27
Page 340
FST 200
7. Online mode
Display of AS-i inputs When you select function F1 the instantaneous values of the connected local digital inputs and outputs are displayed on the screen for you. Browsing with the F1 and F2 keys will bring up a display of the AS-i inputs and the four AS-i status bits.
Fig. 7.16: Display of the AS-i-master inputs