For the Extron IPL T S1, Extron IPL T S4 and Extron IPL T S2

Page 21

Crossover Cable

Pins: 12345678

Insert Twisted Pair Wires

End 2 Wire color

End 1 Wire color

End 2 Wire color

White-orange

1 White-orange

White-orange

2 Green

Orange

2

Orange

3 White-orange

White-green

3 White-green

White-green

4 Blue

Blue

4 Blue

Blue

5 White-blue

White-blue

5 White-blue

White-blue

6 Orange

Green

6

Green

7 White-brown

White-brown

7 White-brown

White-brown

8 Brown

Brown

8 Brown

Brown

T568A

RJ-45 Connector

Straight-through Cable

1 White-green

Pin

End 1 Wire color

Pin

Orange

Green

T568B

T568B

A cable that is wired as T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crossover" cable.

T568B

A cable wired the same at both ends is called a "straight-through" cable, because no pin/pair assignments are swapped.

Figure 7. RJ-45 Connector Wiring

Serial Device Connection There are two types of serial connections: zz 9-pin D connectors zz Captive screw connectors

9-pin D connector Connect any audio or video device to any one of the COM ports on the rear panel of an IPL T S Series controller using a serial cable with a 9-pin D connector. IPL T S2 COM1

MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .5A MAX

LAN

COM2 COM1

COM2

TX RX

TX RX

COM Ports with 9-pin D Connectors

5

1

9 6 9-Pin D Connector Pinouts

Pin 2 3 5 7 8

Function Receive Data/Receive Data Transmit Data/Transmit Data Signal Ground Request to Send/Transmit Data + Clear to Send/Receive Data +

RS-232 RS-422 RX TX GND RTS CTS

RXTXGND TX+ RX+

RS-485 Data Tie 2 & 3 GND Data + Tie 7 & 8

Figure 8. 9-pin D Connector Pinouts NOTE:

IPL T S1 supports RS-232 only. With RS-485, Data + can connect to pin 7 or 8. Data - can connect to pin 2 or 3. IPL T Series • Setup

15

Page 22

Captive screw connector The IPL T S2, IPL T S6, and IPL T SFI244 have COM ports with captive screw connectors. The two COM ports with captive screw connectors on the IPL T S2 are common to the two 9-pin D connectors. Only one connector can be used for each COM port. If you use a COM port captive screw connector, its 9-pin D port is not accessible. The IPL T S6 has four COM ports with captive screw connectors that are independent of COM ports 1 and 2, which have 9-pin D connectors.

COM1 TX RX RTS CTS

COM 2 TX RX

Transmit (Tx) Receive (Rx) Ground (GND) Request to Send (RTS) Clear to Send (CTS)

Transmit (Tx) Receive (Rx) Ground (GND)

The female captive screw connectors accept 3-pole or 5-pole male captive screw connectors that are wired as shown in the diagram below.

Strip wires 3/16" (5 mm) max.

Figure 9. 3-pole and 5-pole Captive Screw Connector Wiring

Relay Ports The IPL T CR48 has eight relay ports that provide contact closure activation of relays (for power, screen projector, lift control, drapes, and so on) when trigger events occur. See the diagram below for relay port wiring. Normally open

Closed

RELAY 2 1

IPL T CR48 Rear Panel

To Room Control Equipment

Figure 10. Relay Port Wiring

16

IPL T Series • Setup

Page 23

IR Ports The IPL T SFI244 has four IR ports for infrared device connection. You can connect IR emitters or a wired IR control port of another device to send IR signals (with or without carrier frequencies) to display or source devices. See the diagram below for IR port wiring. 1

IR

2

IPL T SFI244 Rear Panel

IR Output Ground ( )

S G S G

To Projector, Panel Display, or Source Device’s Wired IR Remote Port or IR emitter

Figure 11. IR Port Wiring

Contact Closure Input Ports The IPL T CR48 has four contact closure inputs that permit the connection of switches and sensors to provide input (trigger events) to the system. Pins 1 through 4 select inputs 1 through 4 on a connected switcher or projector; pin 5 is a ground pin. See the diagram below for contact closure input port wiring. 1

INPUT 2 3 4

IPL T CR48 Rear Panel

Heat Shrink Over Shield

4 3 2 1

Switch, Sensor

Figure 12. Contact Closure Input Port Wiring

IPL T Series • Setup

17

Page 24

Flex I/O Ports The IPL T SFI244 has four Flex I/O ports that can be configured as digital inputs, digital outputs, or analog inputs. When configured as digital inputs, the Flex I/O ports can connect to switches and sensors. When configured as digital outputs, the Flex I/O ports can drive devices that accept a TTL input signal. When configured as analog inputs, these Flex I/O ports can receive analog voltages for use with photo sensors, level feedback, and other devices. See the diagram below for Flex I/O port wiring. NOTE:

Be sure to wire appropriately based on the configuration of the port. FLEX I/O

12 V + −

1 2 3 4

IPL T SFI244

INPUTS 1 2 3 4 C

IPA T RLY4

Figure 13. Flex I/O Port Wiring

Configuring for Network Communication To function together, both the PC and the IPL T controller must be configured correctly. The PC must be network-capable with the proper protocols and the IPL T controller must be set up so that it can be connected to a LAN or other network. When you power on the IPL T controller for the first time, there are several ways to set up the IP address: zz Use the Global Configurator software, Refer to the Global

Configurator Help file. zz Use the ARP (Address Resolution Protocol), See the instructions that follow. zz Use a Web browser, Refer to the IPL T Series User Guide,

IPL T SFI244 User Guide, or IPL T CR48 User Guide, depending on the controller. zz Use SIS (Simple Instruction Set™) commands via Telnet, Refer to the IPL T Series User Guide, IPL T SFI244 User Guide, or IPL T CR48 User Guide, depending on the controller. The first time you connect a PC to an IPL T controller via IP, you may need to temporarily change the IP settings of the PC in order to communicate with the controller. That process is described in the IPL T Series User Guide, IPL T SFI244 User Guide, and IPL T CR48 User Guide. 18

IPL T Series • Setup

Page 25

Then, you must change the default settings of the controller (IP address, subnet mask, and [optional] administrator name and password) in order to use the controller on an intranet (LAN) or on the Internet. After you have set up the IPL T controller for network communication, you can reset the PC to its original network configuration. NOTE:

Both the computer and the IPL T controller must be connected to the same subnet on a LAN (using a straight-through cable). Alternatively, you can use a crossover Ethernet cable to connect the controller directly to the network adapter card of the computer.

Use ARP to configure the IP address as follows: 1. Obtain a valid IP address for the IPL T controller from the network administrator. 2. Obtain the MAC address of the IPL T controller from the label on its rear panel. The MAC address should have this format: 00-05-A6-xx-xx-xx. 3. If the IPL T controller has never been configured and is still set for factory defaults, go to step 4. If not, perform a Mode 4 system reset. See Resetting the Controller for more information. CAUTION:

The IPL T controller must be configured with the factory default IP address (192.168.254.254) before the ARP command is executed, as described in the following steps.

4. On the PC, access the command prompt, then execute the arp -s command. Enter the desired new IP address for the controller and the MAC address (located on the rear panel of the controller). For example: arp -s 10.13.170.15 00-05-A6-00-0A-90

Figure 14. Executing the ARP Command

IPL T Series • Setup

19

Page 26

5. Execute a ping command by typing ping followed by a space and the new IP address at the command prompt. For example: ping 10.13.170.15 After issuing this command, the controller changes to the new address and starts responding to the ping requests, as described. You must ping the IPL T controller in order for the IP address change to take place.

Figure 15. Controller Response to a Ping Request You can reconnect using either Telnet or a Web browser to verify that the update was successful. 6. After verifying that the change was successful, enter and issue the Arp -d command at the command prompt. For example: arp -d 10.13.170.15 removes the 10.13.170.15 from the ARP table - or arp -d* removes all static IP addresses from the ARP table.

Configuring the IPL T Series with Global Configurator After you have installed the Global Configurator (GC) software on the PC and downloaded device drivers, do the following: 1. Create a GC project file. 2. Configure the IPL T Series controller and other devices. 3. Launch the GlobalViewer® interface. 4. Test the configuration and the system. Refer to the Global Configurator Help file for these procedures. The Global Configurator Help file includes an introduction to the software and a section on how to start a Global Configurator project. It also features step-by-step instructions on the basic tasks involved in configuring an IPL T controller. If you have questions during installation and setup, you can call the Extron S3 Sales & Technical Support Hotline or the Extron S3 Control Systems Support Hotline.

20

IPL T Series • Setup

Page 27

IPL T Series • Setup

21

Page 28

Extron® Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to: USA, Canada, South America, and Central America: Extron USA 1001 East Ball Road Anaheim, CA 92805 U.S.A.

Japan: Extron Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan

Europe, Africa, and the Middle East: Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands

China: Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China

Asia: Extron Asia 135 Joo Seng Road #04-01 PM Industrial Bldg. Singapore 368363 Singapore

Middle East: Extron Middle East Dubai Airport Free Zone F12, PO Box 293666 United Arab Emirates, Dubai

This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions, or modifications to the product that were not authorized by Extron.

NOTE:

If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), +31.33.453.4040 (Europe), +65.6383.4400 (Asia), or +81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.

Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions. Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage. Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.

Page 29

Setup Guide Checklist Install Global Configurator. zz Download from www.extron.com

- or zz Install from Extron Software Products Disk

Make the necessary IPL T Series cable connections. Power Local Area Network (LAN) A/V devices Create a Global Configurator (GC) project file. Add and configure the IPL T Series controller and other devices. Build and upload the GC project file. Launch the GlobalViewer® interface. Refer to the Global Configurator Help file for these procedures. Download device drivers. Create a new Global Configurator project file. Add a device. Define the location of the new device. Save the new Global Configurator file. Configure contacts. Configure e-mail. Assign device drivers. Set scheduled actions and e-mail deliveries. Set monitored conditions. Build the Global Configurator file. Upload the Global Configurator file. Change device settings such as the e-mail server (if desired). Launch the GlobalViewer interface.

Extron USA - West Headquarters

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

+800.633.9876

+800.633.9876

+800.3987.6673

+800.7339.8766 Inside Asia Only

+81.3.3511.7655 +81.3.3511.7656 FAX

+400.883.1568

Inside Europe Only

+971.4.2991800 +971.4.2991880 FAX

+31.33.453.4040 +31.33.453.4050 FAX

+65.6383.4400 +65.6383.4664 FAX

Inside USA/Canada Only +1.714.491.1500 +1.714.491.1517 FAX

Inside USA/Canada Only +1.919.863.1794 +1.919.863.1797 FAX

© 2010 Extron Electronics All rights reserved.

Inside China Only

+86.21.3760.1568 +86.21.3760.1566 FAX www.extron.com