Page 11

Screen Control

Projector Lift Control

Blinds

Projector 4 3 2 1 8 7 6

T

PU

5

IN

Extron IPL T CR48 Ethernet Control Interface GlobalViewer®

1

2

3

4

N

LA WER

PO

V 12 0.5A

TCP/IP Network

Lighting System

A/V Resource Management and Remote Control Application

Figure 3. Typical IPL T CR48 Controller Application

Global Configurator Global Configurator (GC) is a software application that gives you the ability to create a single configuration file of all the controlled devices on their audio/video (A/V) network. There are two types of devices in an A/V system: Controllers, Control devices that have an IP Link enabled Ethernet port for network connectivity, and serial, relay, I/O, or infrared (IR) ports for A/V device connectivity. Controlled devices, A/V products, such as video projectors, displays, VCRs, DVD players, document cameras, projector screens, room lighting systems; all of the equipment that is used to generate an audio and video presentation. Once a global configuration file is built, GC then generates a graphical user interface called GlobalViewer® that allows users to monitor and control all of the A/V devices contained within the GC configuration file. When the configuration file is created, one or more of the IP Link controllers on the network can be designated as a GlobalViewer host device. The completed configuration file is uploaded to the host devices. The GlobalViewer interface can then be launched by opening an Internet browser on a local PC and entering the IP address of the host device in the Address field of the browser.

IPL T Series • Introduction

5

Page 12

Figure 4. Global Configurator Application Screen Using GC you can configure a single room controller or create a Web-based remote monitoring system for hundreds of A/V devices in multiple locations. You can configure an IPL T controller using GC without having the device physically connected to the A/V network. CAUTION:

NOTE:

6

Use Global Configurator version 3.0 or later. Update all PCs and devices running earlier versions of GC.

Ethernet driver support requires Global Configurator 3.0 and firmware version 1.15 or higher.

IPL T Series • Introduction

Page 13

System Requirements The miminum system requirements for the PC on which you install Global Configurator include: zz Intel® Pentium® III, 1 GHz processor zz Microsoft® Windows® XP SP2, Windows Vista®, or Windows 7 zz Microsoft Internet Explorer® 6.0 with ActiveX® enabled

NOTE:

If ActiveX is not enabled, you may get a prompt from the browser or you will see the "Please wait while the files are loading..." message in the GlobalViewer control page.

zz Microsoft Windows Script 5.6 zz 512 MB of RAM zz 50 MB of available hard disk space zz A network connection with a minimum data transfer rate of

10 Mbps, 100 Mbps recommended

Installing Global Configurator Global Configurator software is available for free from Extron. To download and install Global Configurator on your PC: 1. Open your Web browser and go to www.extron.com. 2. Click the Download tab. 3. Click the IP Link® Software icon. 4. Click the Global Configurator icon. 5. Click the Download Now button. 6. Enter the login information for your Extron Web site account. 7. Click Download GCSWxxxxx.exe. 8. Follow the remaining system prompts. To install Global Configurator from an Extron Software Products Disk if Autorun is enabled on your PC: 1. Insert the Extron Software Products Disk into the disk drive of your PC. 2. Wait for the Extron Software Products page to load. 3. Click on the Software icon.

4. Scroll down to the Global Configurator description and click the Install link in the far right column. 5. Follow the remaining system prompts.

IPL T Series • Introduction

7

Page 14

To install Global Configurator from an Extron Software Products Disk if Autorun is not enabled on your PC: 1. Insert the Extron Software Products Disk into the disk drive of your PC. 2. From the Windows desktop, open My Computer and select the appropriate disk drive. 3. Double-click launch.exe. 4. Wait for the Extron Software Products page to load. 5. Click on the Software icon.

6. Scroll down to the Global Configurator description and click the Install link in the far right column. 7. Follow the remaining system prompts.

8

IPL T Series • Introduction

Page 15

Setup This section describes the hardware setup and configuration of the IPL T Series controllers. Topics that are covered include: zz Front Panel Features zz Rear Panel Features zz Resetting the Controller zz Connections and Wiring zz Configuring for Network Communication zz Configuring the IPL T Series with Global Configurator

Front Panel Features IPL T S Series a Power LED, A green LED

COM lights to indicate that the unit is receiving power.

R

TX

RTS

RX

CTS

IPL T S1 b Reset button, Recessed

1 multiple function Reset button. See Resetting the Controller for more information.

2

3 c COM LEDs IPL T S2 zz RX, A green LED lights to indicate that data is being received.

1

CTS

TX

R

RTS

COM lights to indicate that data is being transmitted.

RX zz TX, A green LED

4

100

1

LINK

5

2

ACT

6

2

3 zz RTS, A green LED lights to indicate that the controller is ready to send data. IPL T S4

R

1

2

CTS

RTS

RX

TX

CTS

RTS

RX lights to indicate that a connected device is ready to receive data.

d 100 LED, A green LED

COM TX zz CTS, A green LED

4

100

1

3

LINK

5

2

4

ACT

6

3

3 lights to indicate that the connection speed is 100 Mbps. If the LED is not lit, the connection speed is 10 Mbps. IPL T Series • Setup

9

Page 16

e LINK LED, A green LED

IPL T S6

R f ACT LED, A yellow LED lights to indicate that data is being sent or received.

1

100

RX

TX

TX

RX

COM CTS

RX

RTS

COM TX lights to indicate that the unit is connected to an active network.

1

3

5

LINK

2

4

6

ACT

2

3

3

3

IPL T SFI244 IPL T SFI244 I/O

COM TX

R

RX

1

IR 3

1

3

ACT

2 2

1

3

2

100 LINK

1

4

4

5

2

4

7 8 9

6 a Power LED, A green LED lights to indicate that the unit is receiving power.

b Reset button, Recessed multiple function Reset button. See Resetting the Controller for more information.

c IR learning receiver, This infrared receiver "learns"commands from device IR remote controls. Refer to the IR Learner Software Help file for IR learning procedures.

d COM LEDs zz TX, A green LED lights to indicate that data is being transmitted. zz RX, A green LED lights to indicate that data is being received.

e I/O LEDs, A green LED lights to indicate that an I/O port (1 through 4) is active.

f IR LEDs, A green LED lights to indicate that an IR port (1 through 4) is transmitting data.

g 100 LED, A green LED lights to indicate that the connection speed is 100 Mbps. If the LED is not lit, the connection speed is 10 Mbps.

h LINK LED, A green LED lights to indicate that the unit is connected to an active network.

i ACT LED, A yellow LED lights to indicate that data is being sent or received.

10

IPL T Series • Setup

4 5 6

Page 17

IPL T CR48 IPL T CR48 INPUT R

1

3

2

1

2

4

3

RELAY 1

2

3

5

4

6

100

5

LINK

6

ACT

7

7

8

4 a Power LED, A green LED lights to indicate that the unit is receiving power.

b Reset button, Recessed multiple function Reset button. See Resetting the Controller for more information.

c Input LEDs, A green LED lights to indicate that the port is active. d Relay LEDs, A green LED lights to indicate that the relay is closed and activated.

e 100 LED, A green LED lights to indicate that the connection speed is 100 Mbps. If the LED is not lit, the connection speed is 10 Mbps.

f LINK LED, A green LED lights to indicate that the unit is connected to an active network.

g ACT LED, A yellow LED lights to indicate that data is being sent or received.

Rear Panel Features

8

IPL T S1

IPL T S Series

MAC: 00-05-A6-XX-XX-XX S/N:

12V 0.5A MAX a Power connection, Connect the supplied 12 VDC power supply

1 b LAN port, RJ-45 receptacle 3.5 millimeter, 5-pole captive screw connectors for serial port connections

2

4

COM1

MAC: 00-05-A6-XX-XX-XX S/N: POWER

LAN

12V .5A MAX

1 e COM2, 9-pin D connector for

8 serial port 1 serial port 2 serial port 3

4

IPL T S2 d COM1, 9-pin D connector for f COM3, 9-pin D connector for

LAN

8 for network connection c Captive screw connectors, COM1

COM2 COM1

COM2

TX RX

TX RX

2

3

5

4

6

COM1

COM3

COM2

COM4

5

7

IPL T S4 MAC: 00-05-A6-XX-XX-XX S/N: POWER

LAN

12V .5A MAX

1

2

IPL T Series • Setup

11

Page 18

serial port 4 h MAC address, The unique hardware ID number (MAC address) of the unit (for example, 00-05-A6-00-00-01)

IPL T S6

4

6

COM1

MAC: 00-05-A6-XX-XX-XX S/N: POWER

LAN

12V .5A MAX

1

IPL T SFI244

4

8 g COM4, 9-pin D connector for

COM3

COM4

COM5

COM6

TX RX

TX RX TX RX

TX RX

2

3

COM2

5

5

IPL T SFI244 MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .5A MAX

1

FLEX I/O

LAN

1 2 3 4

COM1

COM2

TX RX

TX RX

2

IR 1

2

3

4

S G S G S G S G

3 a Power connection, Connect the supplied 12 VDC power supply b LAN port, RJ-45 receptacle for network connection c COM ports, 3.5 millimeter captive screw receptacles for serial ports COM1 and COM2 d Flex I/O ports, Four ports that can be configured as digital inputs (for switches or sensors), digital outputs (for power, screen, or projector lift control), or analog inputs (for photo sensors or level feedback)

e IR ports, 3.5 millimeter captive screw receptacles for infrared device connection f MAC address, The unique hardware ID number (MAC address) of the unit (for example, 00-05-A6-00-00-01)

IPL T CR48 5

IPL T CR48 MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .5A MAX

1

LAN

1

3

4

RELAY 1 2 3 4

2

2

INPUT

3

5

6

7

8

4 a Power connection, Connect the supplied 12 VDC power supply. b LAN port, RJ-45 receptacle for network connection c Input (contact closure) ports, Four inputs permit connection of switches and sensors to provide input (trigger events) to the system.

d Relay ports, Eight relay ports provide contact closure activation of relays (for power, screen projector lift control, and so on) when trigger events occur.

e MAC address, The unique hardware ID number (MAC address) of the unit (for example, 00-05-A6-00-00-01)

12

IPL T Series • Setup

Page 19

Resetting the Controller There are five reset modes (numbered 1, 2, 3, 4, 5 for the sake of comparison with other Extron IPL products) available by using the Reset button (b) on the front panel. The Reset button is recessed, so use of a pointed stylus, ballpoint pen, or Extron Tweeker is suggested. CAUTION:

NOTE:

Review the reset modes carefully. Use of the wrong reset mode may result in unintended loss of flash memory programming, reassignment of ports, or a unit reboot.

Reset mode 2 does not apply to the IPL T CR48. IPL T Series Reset Mode Summary

Mode Activation

2

Press and release the Reset button. Within 2 seconds, type +++ on the keyboard.

Result

Purpose/Notes

The IPL T controller reverts to the factory default firmware. Event scripting does not start if the unit is powered on in this mode. All user files and settings (such as drivers, adjustments, and IP settings) are maintained.

Use mode 1 to revert to the factory default firmware version if incompatibility issues arise with user-loaded firmware.

N If you do not want to update firmware, or you performed a mode 1 reset by mistake, cycle power to the unit to return to the firmware version that was running prior to the mode 1 reset. Use the 0Q SIS command to confirm that the factory default firmware is no longer running (look for asterisks following the version number.)

N User-defined Web pages may not work correctly if using an earlier firmware version.

The connected COM port becomes a console port to send SIS commands. Scripting remains on.

Mode 2 enables the SIS console port.

Mode 3 turns events on or off. If the events are currently stopped following the momentary press, the Power LED flashes twice, indicating the starting of events. If the events are currently running following the momentary press, the Power LED flashes three times indicating the stopping of events.

Mode 3 is useful for troubleshooting.

Mode 4 • Enables ARP capability. • Sets the IP address back to factory default (192.168.254.254). • Sets the subnet back to factory default. • Sets the default gateway address to the factory default. • Sets port mapping back to factory default. • Turns DHCP off. • Turns events off.

Mode 4 enables you to set IP address information using ARP and the MAC address.

Mode 5 performs a complete reset to factory defaults (except the firmware). • Does everything mode 4 does. • Clears driver-port associations and port configurations (IR/RS-232). • Removes button/touchpanel configurations. • Resets all IP options. • Removes scheduling settings. • Removes/clears all files from the IPL T controller.

Mode 5 is useful if you want to start over with configuration and uploading, and also to replace events.

N If the three “+’s” (+++) are not enetered in the 2-second time frame, the COM port becomes a control port only. 3

Hold down the Reset button for about 3 seconds until the Power LED blinks once, then release and press Reset momentarily (<1 second) within 1 second.

4

Hold down the Reset button for about 6 sec. until the Power LED blinks twice (once at 3 seconds, again at 6 seconds). Then release and press Reset momentarily (for <1 second) within 1 second.

N Nothing happens if the momentary press does not occur within 1 second.

Reset all IP Settings Reset to Factory Defaults

Hold down the recessed Reset button while applying power to the IPL T controller. N After a mode 1 reset is performed, update the firmware of the unit to the latest version. Do not operate the IPL T controller firmware version that results from the mode 1 reset. This mode temporarily resets the unit to factory default until power is recycled. If you want to use the factory default firmware, you must upload that version again.

Run/Stop Events

Enable Serial Console

Use Factory Firmware

1

N Nothing happens if the momentary press does not occur within 1 second. 5

Hold down the Reset button for about 9 seconds until the Power LED blinks three times (once at 3 seconds, again at 6 seconds, again at 9 seconds). Then release and press Reset momentarily (for <1 second) within 1 second. N Nothing happens if the momentary press does not occur within 1 second.

Figure 5. Reset Mode Summary

IPL T Series • Setup

13

Page 20

Connections and Wiring Power Connection To connect the power supply: 1. Insert the 2-pole captive screw connector into the power supply receptacle on the rear panel of the controller. A

Ridges

Smooth

SECTION A–A

A

3/16” (5 mm) Max.

Power Supply Output Cord

MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .5A MAX

FLEX I/O

LAN COM1

COM2

TX RX

TX RX

IR

1 2 3 4

1

2

3

4

S G S G S G S G

Power Supply Receptacle

DC Power Cord Captive Screw Connector

Ground +12 VDC

External Power Supply (12 VDC, 1 A ) AC Power Cord

Figure 6. Power Connector Wiring 2. Connect the female end of the AC power cord into the power supply and the male end into a 110-220 VAC outlet.

Local Area Network (LAN) Connection Connect a patch (straight-through) Ethernet cable to the LAN port on the rear panel if you are connecting the controller to a switch, hub, or router on your A/V network. Connect a crossover Ethernet cable to the LAN receptacle on the rear panel if you are connecting the controller directly to a PC. MAC: 00-05-A6-XX-XX-XX S/N: POWER 12V .5A MAX

FLEX I/O

LAN COM1

COM2

TX RX

TX RX

1 2 3 4

IR 1

2

3

S G S G S G S G

Local Area Network (LAN) Receptacle

14

IPL T Series • Setup

4