Page 63

TM-T88II/T88III Technical Reference Guide

Appendix A

Interfaces and Connectors A.1 RS-232 Serial Interface A.1.1 Interface Board Specifications (RS-232-compliant) Table A-1 Serial interface specifications Item

Specifications

Data transfer method

Serial

Synchronization

Asynchronous

Handshake

Select one of the following with DIP SW1-3: ❏ DTR/DSR (DIP SW1-3 OFF) ❏ XON/XOFF (DIP SW1-3 ON)

Signal level

MARK

–3 V to –15 V logic “1” /ON

SPACE

+3 V to +15 V logic “0” /OFF

Bit length

Select one of the following with DIP SW1-4: ❏ 7 bit (DIP SW1-4 ON) ❏ 8 bit (DIP SW1-4 OFF)

default default

Baud rate

Select one of the following with DIP SW1-7 and SW1-8: ❏ 19200 bps (DIP SW1-7 OFF, DIP SW1-8 OFF) ❏ 9600 bps (DIP SW1-7 ON, DIP SW1-8 OFF)default ❏ 4800 bps (DIP SW1-7 OFF, DIP SW1-8 ON) ❏ 2400 bps (T88ii) or 38400 bps (T88III) (DIP SW1-7 ON, DIP SW1-8 ON) [bps: bits per second]

Parity check

Select one of the following with DIP SW1-5: ❏ Yes (DIP SW1-5 ON) ❏ No (DIP SW1-5 OFF)

Parity selection

Select one of the following with DIP SW1-6: ❏ Even (DIP SW1-6 ON) ❏ Odd (DIP SW1-6 OFF)

Stop bit

1 or more bits However, the stop bit for data transfer from the printer is fixed to 1 bit.

Connector

Rev. A

Printer side

DSUB 25-pin (female) connector

Interfaces and Connectors A-1

Page 64

A.1.2 Functions of each Connector Pin Table A-2 Pin assignments Pin no.

Signal name

Signal direction

1

FG

2

TXD

Output

Transmission data

3

RXD

Input

Reception data

4

RTS

Output

Equivalent to DTR signal (pin 20)

6

DSR

Input

This signal indicates whether the host computer can receive data. SPACE indicates that the host computer can receive data. MARK indicates that the host computer cannot receive data. When DTR/DSR control is selected, the printer transmits data after confirming this signal (except if transmitted using some ESC/POS commands). When XON/XOFF control is selected, the printer does not check this signal. Changing DIP SW2-7 lets this signal be used as a printer reset signal. When you use this signal as the printer’s reset signal, the printer is reset when the signal remains MARK for a pulse width of 1 ms or more.

7

SG

20

DTR

Output

1) When DTR/DSR control is selected, this signal indicates whether the printer is Busy. SPACE status, indicates the printer is ready to receive data. MARK status, indicates the printer is Busy. Set Busy conditions with DIP SW2-1. (Refer to “Busy State” on page 3-11). 2) When XON/XOFF control is selected, the signal indicates that the printer is properly connected and ready to receive data from the host. SPACE status, indicates the printer is properly connected and ready to receive data from the host. The signal is always SPACE, except in the following cases: • During the period from when power is turned on to when the printer is ready to receive data. • During the self-test.

25

INIT

Input

Changing DIP SW2-8 enables this signal to be used as a reset signal for the printer. The printer is reset if the signal remains at SPACE for a pulse width of 1 ms or more.

Function Frame ground

Signal ground

A.1.3 XON/XOFF When XON/XOFF control is selected, the printer transmits the XON or XOFF signals as follows. The transmission timing of XON/XOFF differs, depending on the setting of DIP SW2-1. Table A-3 XON/XOFF transmissions Signal

XON

XOFF

Printer status

DIP SW2-1 status 1 (ON)

0 (OFF)

1) When the printer goes online after turning on the power (or reset using the interface)

Transmit

Transmit

2) When the receive buffer is released from the buffer full state

Transmit

Transmit

3) When the printer switches from offline to online, Transmit

4) When the printer recovers from an error using some ESC/POS commands, Transmit

5) When the receive buffer becomes full

Transmit

Transmit

6) When the printer switches from online to offline, Transmit

A-2 Interfaces and Connectors

Rev. A

Page 65

TM-T88II/T88III Technical Reference Guide

A.1.4 Code The hexadecimal numbers corresponding to the XON/XOFF codes are shown below. ❏ XON code:

11H

❏ XOFF code:

13H

Note: When the printer goes from offline to online and the receive buffer is full, XON is not transmitted. When the printer goes from online to offline and the receive buffer is full, XOFF is not transmitted. When memory switch MSW 1-3 is off, XON is not transmitted as long as the printer is offline, even if a receive buffer full state has been cleared.

A.2 IEEE 1284 Parallel Interface A.2.1 Modes The IEEE 1284 parallel interface supports the following two modes. Table A-4 Parallel modes Mode

Communication direction

Other information

Compatibility mode

Host → Printer communication

Centronics-compliant

Reverse mode

Printer → Host communication

Assumes a data transfer from an asynchronous printer

Compatibility mode Compatibility mode allows data transmission from host to printer only: Centronics-compatible. Specifications •

Data transmission:

8-bit parallel

•

Synchronization:

Externally supplied STROBE* signals

•

Handshaking:

ACK* and BUSY signals

•

Signal levels:

TTL-compatible connector

•

Connector:

ADS-B36BLFDR176 (HONDA) or equivalent product (IEEE 1284 Type B)

•

Reverse communication:

Nibble or byte mode

*A rule above a signal name indicates an “L” active signal.

Rev. A

Interfaces and Connectors A-3

Page 66

Reverse mode The transfer of status data from the printer to the host proceeds in the nibble or byte mode. This mode allows data transfer from an asynchronous printer under the control of the host. Data transfers in the nibble mode are made via the existing control lines in units of four bits (a nibble). In the byte mode, data transfer proceeds by making the 8-bit data lines bidirectional. Both modes fail to proceed concurrently in the compatibility mode, thereby causing half-duplex transmission.

A-4 Interfaces and Connectors

Rev. A

Page 67

TM-T88II/T88III Technical Reference Guide

A.2.2 Interface Signals Table A-5 Connector pin assignments Pin

Source

Compatibility Mode

Nibble Mode

Byte Mode

1

Host

Strobe

HostClk

HostClk

2

Host/Ptr

Data0(LSB)

Data0 (LSB)

Data0 (LSB)

3

Host/Ptr

Data1

Data1

Data1

4

Host/Ptr

Data2

Data2

Data2

5

Host/Ptr

Data3

Data3

Data3

6

Host/Ptr

Data4

Data4

Data4

7

Host/Ptr

Data5

Data5

Data5

8

Host/Ptr

Data6

Data6

Data6

9

Host/Ptr

Data7 (MSB)

Data7 (MSB)

Data7 (MSB)

10

Printer

Ack

PtrClk

PtrClk

11

Printer

Busy

PtrBusy/Data3, 7

PtrBusy

12

Printer

Perror

AckDataReq/Data2, 6

AckDataReq

13

Printer

Select

Xflag/Data1, 5

Xflag

14

Host

AutoFd

HostBusy k

HostBusy

15

NC

ND

ND

16

GND

GND

GND

17

FG

FG

FG

Logic-H

Logic-H

Logic-H

19

GND

GND

GND

20

GND

GND

GND

21

GND

GND

GND

22

GND

GND

GND

23

GND

GND

GND

24

GND

GND

GND

25

GND

GND

GND

26

GND

GND

GND

27

GND

GND

GND

28

GND

GND

GND

29

GND

GND

GND

30

GND

GND

GND

Init

Init

Init

18

Printer

31

Host

32

Printer

33 34

Printer

Fault

DataAvail/Data0, 4

DataAvail

GND

ND

ND

DK_STATUS

ND

ND

35

Printer

+5V

ND

ND

36

Host

SelectIn

1284-Active

1284-Active

* NC: Not Connected ND: Not Defined

Rev. A

Interfaces and Connectors A-5

Page 68

Note: A signal name with a rule above it indicates an “L” active signal. Bidirectional communications cannot take place, unless all signal names for both sides correspond to each other. Connect all signal lines using a twisted-pair cable. Connect the return side to the signal ground level. Make sure the signals satisfy electrical characteristics. Set the leading edge and trailing edge times to 0.5 µs or less. Do not ignore Ack or BUSY signals during a data transfer. Ignoring such signals may result in data corruption. Make the interface cables as short as possible.

A-6 Interfaces and Connectors

Rev. A