Page 21

3 ‹ Configuring and Installing Units

7500 Series User Manual

For RS-422/485 bidirectional protocols, the setup is the following: L AN (local ar ea n et w or k )

Status

Vin

Rtn

-

(AC/DC)

Rly

Rly

Tx

Pwr

Out

In

Tx+

In Gnd

Rx

RS232

Rx+

RS422/485

LAN 10/100

Rtn

Vin

(AC/DC)

Rly

-

Pwr

Out Rly

Tx

In

Tx+

In Gnd

Rx

RS232

Rx+

RS422/485

LAN 10/100

Status

Tx+ Tx- Rx+ Rx- Gnd

Tx+ Tx- Rx+ Rx- Gnd

Tx+ Tx- Rx+ Rx- Gnd

Tx+ Tx- Rx+ Rx- Gnd

For the RS-422/485 Pelco P or D protocols, connect the serial ports as shown in the diagram below: L A N (l ocal ar ea n et w or k )

Pwr

Vin

(AC/DC)

Rtn

-

Rly

Out Rly

In Gnd

Rx

Tx

RS232

Rx+

RS422/485

LAN 10/100

Tx+

Vin

Status

In

Pwr

(AC/DC)

Rtn

Rly

In

-

Out Rly

In Gnd

Tx

-

Tx+

Rx

RS232

Rx+

RS422/485

LAN 10/100

Status

Rx+ Rx- Gnd

Tx+ Tx- Gnd

Rx+ Rx- Gnd

Tx+ Tx- Gnd

A typical connection of a multidrop RS-485 network (a number of terminals sharing the same line) is presented in Appendix B, page 27.

Configuring Audio Encoders/decoders with audio capabilities have two 3.5 mm stereo. The 7500 Series supports both the full duplex bidirectional mode and the push-to-talk/push-to-listen (PTT/PTL) mode. You can set the mode in Device Configurator when creating a point-to-point connection or in the Config Tool if you use NVRS.

13

Page 22

3 ‹ Configuring and Installing Units

7500 Series User Manual

The PTT/PTL mode allows you to control audio communication between two units. If the PTT switch is pressed, the audio transmission circuit is activated. If both the transmitter and receiver PTT switches are activated at the same time, the receiver’s will have precedence; audio will be transferred from the receiver to the transmitter. If the receiver's PTT and PTL functions are activated at the same time, PTT will be activated and PTL will be ignored. Here is a typical application of the PTT/PTL audio mode. LAN S1500e-T

S1500e-R

Audio In Connector

Audio Out Connector

Gnd and In pins

Audio In Connector

Audio Out Connector

PTT

PTT PTL

In full duplex mode, audio data is always transferred in both directions. Appendix G, page 37, presents the audio input/output specifications along with connector descriptions for the 7504M unit.

Audio Output using Full Duplex Mode In full duplex mode for audio output, you can use either a 3.5 mm mono or 3.5 mm stereo jack.

Audio Input using PTT/PTL or Full Duplex Mode Audio supports two input types: line-in and micro (with preamplifier). If you wish to use a multimedia microphone (Electret), set the input type to micro in Device Configurator (Audio configuration tab). Most multimedia microphones use a 3.5 mm stereo jack. The line-in audio input type is the default value for both the receiver and transmitter. In this mode, a 3.5 mm stereo jack or a 3.5 mm mono jack may be used.

Audio Output using PTT/PTL Mode Audio output setups vary depending on the unit.

‹

7504M - Use a 3.5 mm stereo jack to integrate the PTT button.

‹

All other units - Use the In dry contact 2 on the 12-pin connector to integrate the PTT button.

On all units, a normally open switch has to be connected between the Gnd and In pins on the terminal strip connector.

Performing a Hardware Reset If during configuration the system becomes unstable or stops responding (possibly due to the entering of a wrong value via the CLI), it is possible to perform a hardware reset. This operation will cause the unit to revert to its original factory-configured parameters (listed in Appendix A, page 25). To reset the unit parameters to their factory defaults without performing a hardware operation, see page 22. Following a reset, the unit may need to be reconfigued for proper operation within its network.

7501E, 7501D and 7502M Units To perform a hardware reset, use the Reset button located on the front panel.

To perform a hardware reset:

1

Press and hold the Reset button. The status LED flashes red very rapidly.

2

Hold the button for an additional five seconds, until the LED turns off.

The unit reboots with the default parameters.

14

Page 23

3 ‹ Configuring and Installing Units

7500 Series User Manual

7504M Unit The hardware reset is invoked by shorting together the CTS and TxD pins of the serial port during the power-up sequence.

To perform a hardware reset:

1 2 3 4

Power down the unit. Short the TxD and CTS conductors together (pins 3 and 8 on the DB-9 connector). Power up the unit and wait until the normal boot-up sequence is completed. Remove the short on the TxD and CTS pins.

The unit reboots with the default parameters.

Understanding the Status LED The status LED is a bicolor (green-red) LED that provides detailed information on the current state of the system.

Condition

Indication

-E, -M

-R

Steady red

The unit is powering up.

3

3

Flashing red (0.1 sec. intervals)

The IP address of the unit is already assigned to another unit in the network.

3

3

Flashing green (3 sec. intervals)

The firmware has started, but the unit is not connected to the network.

3

3

Flashing green (1 sec. intervals)

The firmware has started, the unit is connected to the network, but no video/audio/serial* data is transmitted.

3

The firmware has started, the unit is connected to the network, but no video is received or audio/serial* data is received/transmitted. Flashing green (0.5 sec. The firmware has started, the unit is connected intervals) to the network, and video/audio/serial* data is transmitted.

3

3

The firmware has started, the unit is connected to the network, and video is received or audio/ serial* data is received/transmitted.

3

Three consecutive red blinks every 3 to 5 sec.

No video input is detected.

3

Flashing green-red (1 sec. intervals)

The unit is undergoing a firmware update.

3

3

Flashing red (0.1 sec. intervals)

The unit is being identified.

3

3

One red blink

A video packet is lost. In the worst case, it could flash at 5 Hz.

3

* At least one of them must be transferred to obtain the LED condition.

Warning The following power-up conditions are abnormal: ‹ LED not lit: Check the power supply and cabling. If power is available and the

LED stays off, call DVTel technical support for assistance. ‹ Steady red LED: There is an internal error that prevents the unit from starting normally. Power down and power back up the unit once. If the condition persists, proceed to a firmware update (for details, refer to the Device Configurator User Manual). If the update fails or the condition persists after the update, call DVTel technical support for assistance. ‹ Flashing red LED (2 second intervals): There is an internal error that prevents the unit from operating normally. This situation may happen after a firmware update or after the first boot-up. Power down and call DVTel technical support for assistance. ‹ Flashing green-red LED not during a firmware update: The unit is in backup mode; you will need to perform a firmware update using a serial connection.

15

Page 24

4

Setting Parameters with the CLI The 7500 Series units come with a simple command line interface (CLI) for configuration purposes. The CLI is hierarchically organized, with menus, sub-menus, and individual options representing configuration parameters. Only the parameters that you are likely to change are described in this document.

Your 7500 Series system is configured to interface, right out of the box, with the most popular camera data port configurations (4800 baud, 8 data bits, no parity, 1 stop bit).

16

Page 25

4 ‹ Setting Parameters with the CLI

7500 Series User Manual

Getting Started You can access the CLI the following ways:

‹

With a network connection and the Telnet command

‹

With a serial connection and the Device Configurator application (see Appendix E, page 33)

‹

With a serial connection and a terminal emulation program such as HyperTerminal (see Appendix F, page 34)

Starting the CLI with Telnet You can use the Telnet command to open the command line interface of the 7500 Series.

Note Ensure that your PC and the 7500 Series unit are in the same IP subnet.

To enter the CLI with Telnet:

1 2

Start the Command Prompt Windows accessory. At the command line, type telnet followed by the IP address of the unit, then press Enter.

The CLI main menu appears.

The CLI has a timeout that is triggered after three minutes of inactivity. When the timeout occurs you will be brought back to the Command Prompt command line. To reactivate the CLI, re-enter the telnet command.

3

To end the CLI work session: ™

Save your settings by entering s at the main menu and pressing Enter.

™

Exit the CLI by entering q at the main menu and pressing Enter.

Using the CLI To work through the CLI menu structure, follow these guidelines:

‹

To execute a command, press Enter after typing in the corresponding letter or number.

‹

All letters entered in the CLI must be lowercase.

‹

Entering p returns you to the previous menu.

‹

Entering s saves all the changes you have made in the work session.

‹

To exit, enter q in the main menu. Depending on the changed settings, the unit may perform a soft reboot.

17

Page 26

4 ‹ Setting Parameters with the CLI

7500 Series User Manual

Serial Ports The Serial Port menu enables you to establish proper settings ensuring compatibility between the 7500 Series unit and your serial equipment (for example, dome, keyboard, matrix, multiplexer, or access card). For more information about the serial port settings of the specific product with which you want to interface, refer to its user manual or contact your product manufacturer. Depending on the unit, you can set one or two serial ports. On 7504M units, there is only one serial port; therefore the settings apply to the chosen one.

On all other units, you have access to two independent serial ports.

For the RS-232 port, the available commands are:

For the RS-422/485 port, you have access to the following settings:

Bit Rate The bit rate represents the data rate at which the target product operates. Possible values range from 1200 bps to 230,400 bps (for a transmitter) or to 115,200 bps (for a receiver).

Parity The serial equipment may have a parity of odd or even. It may also not have parity check at all; most communication devices do not use parity.

Line Driver For 7501E, 7501D and 7502M units, the line driver option is unavailable, since the units have two independent serial ports. For 7504M units, the default setting is to automatically detect the electrical line interface of the serial port (RS-232 or RS-422/485). However, if your system cannot properly detect the electrical level (for instance, when there is too much noise on the line or too much signal attenuation due to long cable length), you can use the line driver setting to force its electrical line interface.

18

Page 27

4 ‹ Setting Parameters with the CLI

7500 Series User Manual

Here are the possible line driver settings, where -d indicates that the auto-detection mode is activated, and -f, that the line driver is forced:

Setting

Description

232f-d

RS-232 auto-detected, full-duplex operation

232f-f

RS-232 forced, full-duplex operation

485f-d

RS-422/485 auto-detected, 4-wire full-duplex, RS-485 operation

485h-d

RS-422/485 auto-detected, 2-wire half-duplex, RS-485 operation

485h-f

RS-422/485 forced, 2-wire half-duplex, RS-485 operation

485f-f

RS-422/485 forced, 4-wire full-duplex, RS-485 operation

422f-d

RS-422/485 auto-detected, 4-wire full-duplex, RS-422 operation

422f-f

RS-422/485 forced, 4-wire full-duplex, RS-422 operation

Warning If the line driver is forced to the RS-422/485 setting, you will not have access to the CLI unless you use an RS-485 to RS-232 converter or perform a factory reset (described on page 14).

RS-422/485 Operating Mode The operating mode setting enables you to establish the way your RS-422/485 serial equipment will interface with the 7500 Series unit. The supported modes are:

‹ ‹ ‹

RS422 4 Wire RS485 4 Wire RS485 2 Wire

System Status The system status information indicates the current values of internal unit parameters, including the serial number and firmware version. A transmitter and a receiver connected together must have the same firmware version. A value of 03-03 or later in Unit Tested indicates that the unit has an SSL certificate.

19

Page 28

4 ‹ Setting Parameters with the CLI

7500 Series User Manual

Network The Network menu allows you to configure several parameters in order to ensure the compatibility between your unit and the IP network into which it will be integrated.

For more information about these settings, contact your network administrator.

DHCP Configuration DHCP (dynamic host configuration protocol) allows devices and computers connected to a network to automatically get a valid network configuration from a server. For more information about DHCP, see Appendix C, page 29. You can set this option only if the encoder/decoder is connected to a network that uses a DHCP server.

Local IP Address The IP address is the identifier of the 7500 Series unit on the network. The IP address format is a 32-bit numeric address written as four numbers separated by periods. Each number is in the 0-255 range. Each device on a network must have a unique IP address.

Subnet Mask The subnet mask is the binary configuration specifying the subnet in which the IP address of the unit belongs. A subnet is a portion of a network that shares a common address component. On TCP/IP networks, subnets are defined as all devices whose IP addresses have the same prefix. Unless otherwise specified by your network administrator, it is recommended that you use a subnet mask of 255.255.255.0.

Gateway The gateway represents a network point that acts as an entrance to another network.

Ping Request Ping is a basic Internet program that lets you check that a particular IP address exists and can accept requests. You can ping a specific unit by entering its IP address.

UserName/Password The UserName/Password menu gives you the opportunity to protect the unit’s configuration when it is accessed by a serial connection or a Telnet session. When the username/password mode is enabled, configuration by serial port is accessible only if the entered user name and password are correct. The password must be at least four characters long, digits or letters.

20

Page 29

4 ‹ Setting Parameters with the CLI

7500 Series User Manual

Advanced Menu The Advanced menu contains a series of advanced setups used mainly by DVTel technical support. Some of these configuration parameters are available through the Device Configurator utility software.

Identifying a Unit To identify an encoder/decoder among a large set of units, you can make its LED flash red rapidly.

To identify a 7500 Series unit:

1 2 3 4

From the main menu, choose Advanced, then press Enter. Enter i to make the LED flash red. Re-enter i to set the LED to its original state. Enter p until you are in the main menu. Enter q to exit.

Security The Security menu allows access to commands used to protect of the unit. It allows you to:

‹

Prevent access to Telnet sessions

‹

Prevent firmware updates through the IP network

‹

Supply an SSL passkey

Preventing Telnet Sessions By default, Telnet access to 7500 Series units is allowed. To improve the security of your system, you may prohibit this access. The CLI will then only be accessible through a serial connection (with Device Configurator or HyperTerminal).

To prevent Telnet sessions:

1 2 3 4 5

From the main menu, choose Advanced, then press Enter. Choose Security and press Enter. Choose Allow Telnet Session and press Enter. Enter 0 and press Enter. Enter p until you are in the main menu.

21

Page 30

4 ‹ Setting Parameters with the CLI

6

7500 Series User Manual

Enter s to save your changes, then q to exit.

CLI access using a Telnet session is now denied. To enter the CLI or allow Telnet session again, you will need to use a serial connection.

Preventing Firmware Updates You can prevent firmware updates to be performed on your unit through the IP network. By default, this type of update is allowed. For more information about firmware updates, refer to the Device Configurator User Manual.

To prevent firmware updates:

1 2 3 4 5 6

From the main menu, choose Advanced and then press Enter. Choose Security and press Enter. Choose Allow IP Firmware Update, then press Enter. Enter 0, then press Enter. Enter p until you are in the main menu. Enter s to save your changes, then q to exit.

You will not be able to perform firmware updates through the IP network anymore.

Supplying an SSL Passkey To secure a unit with SSL, you need to provide a passkey. This passkey must be the same for all units as well as Device Configurator to allow proper secure communication between them. It is recommended you perform this operation in Device Configurator (version 2.55 or higher); for detailed instructions, refer to the Device Configurator User Manual. Otherwise, to build a truly secure system, you should first access the CLI through a physical serial port connection, rather than through Telnet, in order to avoid eavesdropping on the network.

Load Default Configuration The Load Default Configuration option, located in the main menu, resets all user parameters to their factory settings (described in Appendix A, page 25). All user-defined values will be lost. To reset the unit parameters to their factory defaults with a hardware operation instead, see page 14. Following a configuration reset, the unit may need to be reconfigured for proper operation within its network.

Reboot System The Reboot System functionality, located in the main menu, performs a soft boot. A system reboot clears all unsaved changes in the CLI and returns to your preset configuration.

22