Page 31
On-Screen Display (OSD) The 7500 Series receiver units display information on a video monitor.
23
5
Page 32
5 ‹ On-Screen Display (OSD)
7500 Series User Manual
The information displayed on the video monitor can be broken down into four quadrants as follows:
Quadrant 1 Quadrant 2
Quadrant 4 Quadrant 3
Quadrants 1 and 4 are unused.
Quadrant 2: Video Message When a connection is created between two units, the IP address of the transmitting unit is displayed.
Quadrant 3: Receiver Setup Details Quadrant 3 displays basic unit configuration details, including serial port and network setup. This information is displayed during 45 seconds on startup. For example:
7501D ver: 2.55- build 303 Comm: 4800, 8, N, 1 232f-d IpAddr: 192.168.135.97 SubNet: 255.255.255.0 Gateway: 192.168.135.1 Here is the description of the Comm line:
Serial port
Description
4800
Bit rate
8
Number of data bits
N
Parity: None
1
Number of stop bits
232f-d
Line driver
The “Duplicate IP Detection” message will be displayed if the IP address of the unit is already assigned to another machine in the network.
24
Page 33
A
Factory Default Configuration This appendix lists the factory default configuration of the 7500 Series units.
25
Page 34
A ‹ Factory Default Configuration
7500 Series User Manual
7500 Series units are programmed at the factory with the following configuration:
Type
Configuration
Serial port
‹ Bit rate: 4800 bauds ‹ Parity: none ‹ Line driver: for 7504M, auto-detected ‹ RS-422/485 operating mode: RS-422 4-wire
Network
‹ DHCP configuration: Disabled ‹ IP address: 169.254.*.* (MAC address of the unit) ‹ Subnet mask: 255.255.0.0 ‹ Gateway: 169.254.*.* (MAC address of the unit) ‹ Primary DNS server address: 0.0.0.0 ‹ Backup DNS server address: 0.0.0.0 ‹ Ping request: Target IP address not specified
Video settings
‹ Target frame rate: 30 fps ‹ Target bit rate: 800 Kbps ‹ Maximum quantizer: 10 ‹ Resolution: CIF ‹ Video standard: NTSC
VSIP
‹ VSIP Port: 5510 ‹ VSIP Multicast IP Address: 224.16.32.1 ‹ VSIP Discovery IP Address: 255.255.255.255
Security
‹ Telnet sessions: Enabled ‹ IP firmware update: Enabled ‹ Security profile: Disabled ‹ SSL passkey: <empty>
User name/password
‹ User name: USERNAME ‹ Password: PASSWORD ‹ User name/Password mode: Disabled
26
Page 35
B
RS-485 Multidrop Connections Two multidrop configurations are available:
‹
Four-wire
‹
Two-wire
27
Page 36
B ‹ RS-485 Multidrop Connections
7500 Series User Manual
The four-wire configuration, which can be used for both RS-422 and RS-485, is:
L A N (local ar e
Pwr
Vin
(AC/DC)
LAN 10/100
Rtn
Rly
-
In
Out Rly
In Gnd
Tx
Rx
Tx+
RS232
Rx+
RS422/485
LAN 10/100 Status
RS232 Status
The two-wire configuration, for RS-485 only, is:
L A N (local ar e
Pwr
Vin
(AC/DC)
Rtn
Rly
In
Out Rly
Gnd
In
Rx
Tx
-
Tx+
RS422/485
RS232
Rx+
LAN 10/100
LAN 10/100
28
RS232
Page 37
DHCP Support DHCP (dynamic host configuration protocol) allows devices and computers connected to a network to automatically get a valid network configuration from a DHCP server on that network.
36
Page 38
A ‹ DHCP Support
Device Configurator User Manual
During startup, the Device Configurator determines if a network configuration is stored in its memory or if it must contact a DHCP server to get one. For DVTel units, the network configuration consists of: ‹ ‹ ‹ ‹
An IP address A sub-network mask A default gateway One or two IP addresses of DNS servers (optional)
If the network configuration is stored locally on the unit, the unit uses it and proceeds with starting its applications. If the configuration must be obtained from a DHCP server, the unit must take extra steps to get it before it can start its applications. The unit then tries to contact a DHCP server and get a valid configuration from it. If no DHCP server can be found or no network configuration can be obtained from it within one minute, DHCP configuration fails. A fake network configuration is used instead; the unit then tries to start its applications anyway. The applications on the unit are only started after DHCP completes or fails. If DHCP configuration fails, the unit may not be able to see other devices on the network or may not be visible to them. The fake configuration used by the unit is: ‹ ‹ ‹
IP address:169.254. *. * Subnet mask:255.255.0.0 Default gateway:169.254. *. *
The 169.254. *. * address used by each unit is a unique address based on the MAC address and is determined in accordance with the APIPA service developed by Microsoft. This service allows each unit to find a unique IP address until a DHCP server can provide a complete network configuration. A unit newly upgraded from a previous version of the firmware will have DHCP configuration disabled by default and will retain its current network configuration. The first time a new unit boots up, it has no IP address. It will use a temporary IP address using the APIPA service. Once the user provides a valid network configuration or activates DHCP, the unit reboots and uses the new settings. If you perform a factory setting reset, DHCP support is disabled and the network configuration is deleted. The unit will therefore use an APIPA address the next time it boots.
37
Page 39
DTE and DCE Connections
D
Before connecting a DVTel unit to other serial equipment, you need to determine if they are DTE (data terminal equipment) or DCE (data communication equipment). Here are examples of both equipment types:
‹
DCE - 7500 Series units, 6501E Encoder NTU, modems
‹
DTE - PCs, switches, multiplexers, cameras, keyboards
27
Page 40
D ‹ DTE and DCE Connections
6501E Encoder NTU User Manual
You need to know which equipment type your other serial device is in order to connect it correctly to the 6501E unit, which is a DCE. In the following descriptions:
‹
Voltage is measured when no data is transferred on the Rx and Tx pins.
‹
-X volts represents a negative voltage value.
Data Terminal Equipment DTE modules have the following electrical-level setup:
Pin number
Signal
3
Tx
Measured voltage -X volts
2
Rx
0 volt
Data Communication Equipment DCE modules have the following electrical-level setup:
Pin number
Signal
3
Tx
Measured voltage 0 volt
2
Rx
-X volts
Connecting DTE and DCE When connecting two modules of the same type, you have to cross the data wires to create proper communication. On the other hand, when connecting a DTE with a DCE, a straight cable is required.
DCE DTE DTE
Rx
Rx
Tx
Tx
Rx
Rx
Tx
Tx
Rx
Rx
Tx
Tx
DCE DTE DCE
28